Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) Programming Guide: A - Application Examples, pages 148 to 156

Pages 148 to 156 of 176, from Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) Programming Guide

The original document is the PDF (617 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Allen-Bradley 2755-DS

Page 148

Application Examples

A–31

Configuration Codes for the AdaptaScan Bar Code Readers After making the necessary connections, scan the bar codes starting below to set up the scanner for use with the AdaptaScan. 1. Scan the Set Defaults bar code.

Set Defaults

2. Scan the Single Port RS-232 bar code.

Single Port RS-232

3. Scan the Parity bar code.

None

Publication 2755-6.6

Page 149

A–32

Application Examples

4. Scan the ASCII Format bar code.

8-bit

5. Scan the Stop Bit Select bar code.

1 Stop Bit

The cable defaults work with the AdaptaScan. Your application may have specific requirements. If you change a communication setting, make sure the AdaptaScan is configured to accept the change.

Publication 2755-6.6

Page 150

Application Examples

A–33

AdaptaScan Bar Code Readers Setup You may need to configure the AdaptaScan RS-232 port to accept the scanner data. Verify that the AdaptaScan serial port is configured as shown below. All settings use the default values except for the Enable Pass-Through to DeviceNet check box. Refer to the AdaptaScan Software User Manual (Publication No. 2755-838) for additional information.

1. Default is Terminal. 2. Default is 9600 Baud. 3. Default message length is 0 (sends all data regardless of length). 4. Defaults are: No Parity, 8 Data and 1 Stop Bit. 5. Default is RS-232 Connection. 6. Enable Pass-Through.

Publication 2755-6.6

Page 151

A–34

Application Examples

DTAM Plus DeviceNet This application example describes how to configure and operate the scanners when using an RS-232 cable connected to a DTAM Operator Interface (Catalog Nos. 2707-L8P1, 2707-L8P2, 2707-L40P1, 2707–L40P2, 2707–L40P4, 2707-V40P1, 2707-V40P2, or 2707-V40P2N) on a DeviceNet network.

!

ATTENTION: Do not install the RS-232 cable with power applied to either the base/charger unit or DTAM Operator Interface. Failure to follow this caution may result in damage to the scanner, base/charger unit, or DTAM Operator Interface.

Refer to the following publications for additional information.

• DTAM Plus Operator Interface Module User Manual (Publication No. 2707-800)

• DTAM Plus Devicenet Operator Interface Document Update (Publication No. 2707-800.5)

• DTAM Programming Software Programming Manual (Publication No. 2707-802) • Getting Started with DTAM Plus User Manual (Publication No. 2707-802)

Publication 2755-6.6

Page 152

Application Examples

A–35

Hardware Connections for the DTAM Plus Operator Interface The scanners connect to the DTAM Plus Operator Interface with the RS-232 cable (Catalog No. 2755-HCC-BR1-06). You need to use a 25–9 pin connector as shown below. Base/Charger Unit

To Power Receptacle

RS-232C Cable Power Supply

PLC-5 Controller 25–9 Pin Adapter

1771-SDN Module

DTAM Plus DeviceNet

Publication 2755-6.6

Page 153

A–36

Application Examples

Configuration Codes for the DTAM Plus Operator Interface After making the necessary connections, scan the bar codes starting below to set up the scanner for use with the DTAM Operator Interface. 1. Scan the Set Defaults bar code.

Set Defaults

2. Scan the Single Port RS-232 bar code.

Single Port RS-232

Publication 2755-6.6

Page 154

Application Examples

A–37

3. Scan the following bar codes.

Scan Suffix (Value 1)

7

0

1

3

4. Scan the Data Transmission Format bar code.

<Data><Suffix>

Publication 2755-6.6

Page 155

A–38

Application Examples

5. Scan the Parity bar code.

Even

The cable defaults work with the DTAM Plus Operator Interface. Your application may have specific requirements. If you change a communication setting, make sure the DTAM Plus Operator Interface is configured to accept the change.

DTAM Plus Operator Interface Setup You may need to configure the DTAM Plus Operator Interface RS-232 port to accept the scanner data. Follow the steps below or refer to the DTAM Programming Software Programming Manual (Publication No. 2707-802). 1. Open Screen Builder. 2. Open Create Screen. 3. Open Data Entry Screen. 4. Select Set Up Screen. 5. Select Data Entry. 6. Select ASCII Input. 7. Set up DTAM.

Publication 2755-6.6

Page 156

Application Examples

A–39

DeviceNet Operation The DTAM Plus DeviceNet operates as a Group 2 Server on the DeviceNet network. It supports the Unconnected Message Manager (UCMM). The DTAM Plus DeviceNet implements the predefined master/slave connection set, operating as a slave device. It does not initiate communications except for a Duplicate Node Address check on power-up. The DTAM Plus DeviceNet supports the polled I/O method of exchanging data with a master, in the following sequence: 1. The designated master writes an output image to the DTAM Plus DeviceNet using the Poll Command message. 2. The DTAM Plus DeviceNet responds to the poll command by returning an input image back to the master in a Poll Response message. Note: The size of the input and output images (also referred to as files) are individually configurable from 0 words to 121 words each, to optimize DeviceNet network loading. 3. The DTAM Plus DeviceNet application program interacts with data contained in the input and output files. 4. Data Display screens are used to view input and output data. 5. Data Entry screens are used to modify input and output data from the scanner.

Publication 2755-6.6