The text of a manual · part 16 of 19
Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) Programming Guide: A - Application Examples, pages 138 to 147
Pages 138 to 147 of 176, from Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) Programming Guide
The original document is the PDF (617 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 138
Application Examples
A–21
Hardware Connections for the PLC-5 Controllers The base/charger unit connects to the PLC-5 controllers with an RS-232 cable (Catalog No. 2755-HCC-BR2-06). Base/Charger Unit
RS-232C Cable Power Supply
To Power Receptacle
PLC-5
To Channel 0 Port
Publication 2755-6.6
Page 139
A–22
Application Examples
Configuration Codes for the PLC-5 Controllers After making the necessary connections, scan bar codes starting below to set up the scanner for use with the PLC-5 controllers. 1. Scan the Set Defaults bar code.
Set Defaults
2. Scan the Single Port RS-232 bar code.
Single Port RS-232
Publication 2755-6.6
Page 140
Application Examples
A–23
3. Scan the following bar codes.
Scan Suffix (Value 1)
7
0
1
3
4. Scan the Data Transmission Format bar code.
<Data><Suffix>
Publication 2755-6.6
Page 141
A–24
Application Examples
5. Scan the Parity bar code.
Even
The cable defaults work with the PLC-5 controllers. Your application may have specific requirements. If you change a communication setting, make sure the PLC-5 controllers are configured to accept the change.
Publication 2755-6.6
Page 142
Application Examples
A–25
PLC-5 Controllers Setup You need to configure the Channel 0 port of the PLC-5 controllers. Follow the steps below or refer to the following publications:
• Classic PLC-5 Family Programmable Controllers Hardware Installation Manual (Publication No. 1785-6.6.1)
• PLC-5 Programming Software Instruction Set Reference Manual (Publication No. 6200-6.4.11) • PLC-5 Programming Software Configuration and Maintenance Manual (Publication No. 6200-6.4.6) 1. Set the PLC-5 Channel 0 to User in the Channel 0 Configuration screen.
Publication 2755-6.6
Page 143
A–26
Application Examples
2. Configure Channel 0 in the User Mode Channel 0 Configuration screen.
Note that Termination 1 is set for \0xa or Line Feed [LF], and Termination 2 is set for \0xd or Carriage Return [CR]. These terminators, along with the ARL instruction in the PLC-5 controllers, allow you to read one message at a time with [CR] [LF] terminators.
Publication 2755-6.6
Page 144
Application Examples
A–27
PLC Program The sample ladder logic listing below instructs the PLC-5 controllers to: Rung 2:0 – Read one string of ASCII data terminated with a [CR] [LF].
Publication 2755-6.6
Page 145
A–28
Application Examples
AdaptaScan Pass-Through This application example describes how to configure and operate the scanners when using an RS-232 cable connected to the AdaptaScan bar code reader (Catalog Nos. 2755-SN3, 2755-SN5, and 2755-SN8).
!
ATTENTION: Do not install the RS-232 cable with power applied to either the base/charger unit or AdaptaScan. Failure to follow this caution may result in damage to the scanner, base/charger unit, or AdaptaScan.
Refer to the following publications for additional information.
• AdaptaScan Bar Code Readers User Manual (Publication No. 2755-837) • AdaptaScan Software User Manual (Publication No. 2755-838)
Publication 2755-6.6
Page 146
Application Examples
A–29
Hardware Connections for the AdaptaScan Bar Code Reader The scanner connects to the AdaptaScan wiring base with a custom cable connected to the RS-232 cable (Catalog No. 2755-HCC-BR1-06). Base/Charger Unit
RS-232C Cable Power Supply
To Power Receptacle
Custom Cable (see next page)
AdaptaScan Wiring Base
Publication 2755-6.6
Page 147
A–30
Application Examples
The custom cable for the AdaptaScan Pass-Through Cable connects to the RS-232 and package detect terminals in the AdaptaScan wiring base. 25-Pin Female DB Connector
Custom Cable Maximum length of 18 inches (.46 meter) Transmit (Tx) No Connection Receive (Rx) Clear to Send (CTS) Ready to Send (RTS) Shield (SHD)
AdaptaScan Wiring Base
The following table provides the pinout connections for the cable (DB 25-pin female connector). Pass-Through Cable Pin Number
Function
AdaptaScan Terminal Connection
2
Receive Data Input
Tx (RS-232 Terminal Block)
3
Transmit Data Output
Rx (RS-232 Terminal Block)
4
CTS Input
RTS (RS–232 Terminal Block)
5
RTS Output
CTS (RS-232 Terminal Block)
Shield
Shield Ground
SHD (RS-232 Terminal Block)
Publication 2755-6.6