The text of a manual · part 4 of 21
Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide: 1 - Scanner Configuration (for Synapse Cables), pages 20 to 27
Pages 20 to 27 of 146, from Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide
The original document is the PDF (615 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 20
Scanner Configuration (for Synapse Cables)
1-9
Decode UPC / EAN Supplemental
Ignore UPC / EAN With Supplementals*
Autodiscriminate UPC / EAN with Supplementals
EAN 8 Zero Extend
Do Not Extend EAN 8*
Publication 2755-6.5
Page 21
1-10
Scanner Configuration (for Synapse Cables)
Select UPC / EAN Options (Continued) Scan one of the following Preamble options for UPC-A labels.
No UPC-A Preamble
UPC-A System Character Preamble*
UPC-A System Character and Country Code Preamble
Scan one of the following Preamble options for UPC-E labels.
No UPC-E Preamble
UPC-E System Character Preamble*
UPC-E System Character and Country Code Preamble
Publication 2755-6.5
Page 22
Scanner Configuration (for Synapse Cables)
1-11
Scan one of the symbols below to change the security level. The security level determines the scanner’s ability to read labels without misreads.
Security Level 0 *
Security Level 1
Security Level 2
Security Level 3
Publication 2755-6.5
Page 23
1-12
Scanner Configuration (for Synapse Cables)
Select Codabar Options
Enable NOTIS Editing
Disable NOTIS Editing*
Enable CLSI Editing
Disable CLSI Editing*
Enable Decode Redundancy
Disable Decode Redundancy*
Publication 2755-6.5
Page 24
Scanner Configuration (for Synapse Cables)
1-13
Select Code 39 Options
Verify Code 39 Check Digit
Do Not Verify Code 39 Check Digit*
Enable Code 39 Buffering
Disable Code 39 Buffering*
Clear Code 39 Buffer ➀ Transmit Code 39 Buffer ➀
Enable Code 39 Full ASCII
Disable Code 39 Full ASCII* ➀ The Clear Buffer and Transmit Buffer bar codes are operating functions not configuration codes. Publication 2755-6.5
Page 25
1-14
Scanner Configuration (for Synapse Cables)
Select MSI / Plessey Options
Verify One MSI / Plessey Check Digit*
Verify Two MSI / Plessey Check Digits
If verifying 2 check digits, select Mod 10 - Mod 10 or Mod 11 - Mod 10 format.
MSI 2 Check Digits (Mod 10 - Mod 10)*
MSI 2 Check Digits (Mod 11 - Mod 10)
Publication 2755-6.5
Page 26
Scanner Configuration (for Synapse Cables)
1-15
Select Interleaved and Discrete 2-of-5 Options
Enable I 2 of 5 (14 digit) to EAN 13 Conversion
Disable I 2 of 5 (14 digit) to EAN 13 Conversion*
If entering code lengths, scan the applicable label below followed by the two digit length on the next page. Note: The scanner cannot be set to read ’any’ bar code length. You must specify a length(s).
Discrete 2 of 5 Length 1 (Range 02-31)
Discrete 2 of 5 Length 2 (Range 00*-31)
Interleaved 2 of 5 Length 1 (Range 02-31)
Interleaved 2 of 5 Length 2 (Range 00*-31) Publication 2755-6.5
Page 27
1-16
Scanner Configuration (for Synapse Cables)
Scan 2 Digit Code Length
0 1
2
3
4
5
6
7
8
9
Cancel (Clears Code Length) Publication 2755-6.5