The text of a manual · part 3 of 21
Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide: 1 - Scanner Configuration (for Synapse Cables), pages 12 to 19
Pages 12 to 19 of 146, from Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide
The original document is the PDF (615 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 12
Chapter
1
Scanner Configuration (for Synapse Cables)
Important: Use the bar codes in this section to configure the scanner for use with one of the following Synapse cables: Scanner Emulation Cable (Catalog No. 2755-HFC-SA1-01) IBM XT/AT Keyboard Wedge (Catalog No. 2755-HFC-SP1-01) PS/2 Keyboard Wedge (Catalog No. 2755-HFC-SP2-01) RS-232, 25-pin (Catalog No. 2755-HFC-SR2-01) RS-232, 9-pin (Catalog No. 2755-HFC-SR3-01) DEC VT510/520 Keyboard Wedge (Catalog No. 2755-HFC-SV2–01) DEC VT220/320/420 Keyboard Wedge (Catalog No. 2755-HFC-SV1-01) Do not use these configuration codes if you are using the scanner with an AdaptaScan Pass Through Cable (Catalog No. 2755-HDC-GA2–08). Refer to Chapter 2 Scanner Configuration (for AdaptaScan Pass Through Cable).
Publication 2755-6.5
Page 13
1-2
Scanner Configuration (for Synapse Cables)
Scan These Symbols First Scan both of these labels in sequence to set the scanner to the default settings for use with a Synapse cable.
Scan this Symbol First then
Set Scanner for Synapse Cable Operation
Important: You must then scan the following label to enable Synapse communications.
Enable Synapse Cable Communication
Also scan the ENABLE SYNAPSE CABLE COMMUNICATION bar code to change the configuration from AdaptaScan Pass Through to the Synapse cable configuration. When the Synapse cable communication is enabled, scan the appropriate bar codes to configure the scanner. Then, scan the appropriate bar codes to configure the Synapse cable.
Publication 2755-6.5
Page 14
Scanner Configuration (for Synapse Cables)
1-3
The scanner is now set to these defaults:
Cable Type
Synapse Cable
Code on Page: 1-2
Symbologies
All Enabled
1-4
Transmit UPC-A Check Digit
Enabled
1-8
Transmit UPC-E Check Digit
Enabled
1-8
Convert UPC-E to UPC-A
Disabled
1-8
EAN Zero Extend
Disabled
1-9
Item
Decode UPC / EAN Supplemental
Default Setting
Disabled
1-9
UPC-A Preamble
System Character
1-10
UPC-E Preamble
System Character
1-10
0
1-11
CLSI Editing
Disabled
1-12
NOTIS Editing
Disabled
1-12
Codabar Decode Redundancy
Disabled
1-12
Transmit Code 39 Check Digit
Disabled
1-13
Buffer Code 39
Disabled
1-13
Code 39 Full ASCII
Disabled
1-13
UPC/EAN Security Level
MSI Plessey Check Digit
One
1-14
MSI Plessey 2 Check Digit Algorithm
Mod 10 - Mod 10
1-14
Convert Interleaved 2 of 5 (14 digit) to EAN 13
Disabled
1-15
Interleaved Code Length
14
1-15
Discrete 2 of 5 Code Length
12
1-15
Prefix/Suffix
None
1-17
Data Transmission Format
Data As Is
1-19
Transmit No-Read Message
Disabled
1-20
Transmit Code ID Character
Disabled
1-20
Transmit AIM ID Character
Disabled
1-21
Audible Response
Enabled
1-21
Power Mode
Continuous
1-21
Laser On Timeout
3 Seconds
1-22
Hands-Free Stand Operation Timeout
60 minutes
1-23 Publication 2755-6.5
Page 15
1-4
Scanner Configuration (for Synapse Cables)
Select The Symbologies You Want to Enable or Disable
Enable Code 39*
Disable Code 39
Enable UPC-A*
Disable UPC-A
Enable UPC-E*
Disable UPC-E
Publication 2755-6.5
Page 16
Scanner Configuration (for Synapse Cables)
1-5
Enable Codabar*
Disable Codabar
Enable EAN 8*
Disable EAN 8
Enable EAN 13*
Disable EAN 13
Publication 2755-6.5
Page 17
1-6
Scanner Configuration (for Synapse Cables)
Select The Symbologies You Want to Enable or Disable
Enable Interleaved 2 of 5*
Disable Interleaved 2 of 5
Enable Discrete 2 of 5*
Disable Discrete 2 of 5
Enable Code 128*
Disable Code 128 Note: The scanner is always enabled to read Code 128 configuration codes.
Publication 2755-6.5
Page 18
Scanner Configuration (for Synapse Cables)
1-7
Enable MSI / Plessey*
Disable MSI / Plessey
Enable Code 93*
Disable Code 93
Enable EAN 128*
Delete EAN 128
Publication 2755-6.5
Page 19
1-8
Scanner Configuration (for Synapse Cables)
Select UPC / EAN Options
Transmit UPC-A Check Digit*
Do Not Transmit UPC-A Check Digit
Transmit UPC-E Check Digit*
Do Not Transmit UPC-E Check Digit
Convert UPC-E to UPC-A
Do Not Convert UPC-E to UPC-A*
Publication 2755-6.5