Page 78
Communication Setup (Synapse Cable)
5–17
Country Selection Select the country for the keyboard type the Synapse cable is connected to. The selections are:
• • • • • • • •
North American (default) German French French International Spanish Italian Swedish British
Unknown Characters Unknown characters are characters not recognized by the scanner. When Send Bar Codes with Unknown Characters is enabled (default), all decoded bar code data is transmitted except for the unknown characters. If this option is disabled, bar codes containing one or more unknown characters are not transmitted. Intercharacter Delay Some devices require a delay between characters to simulate the effect of keystroke delays (characters are sent at a lower rate). The default is short delay (5 msec). The options are:
• Short 5 msec delay (default) • Medium 50 msec delay • Long 99 msec delay
Publication 2755-6.4
Page 79
5–18
Communication Setup (Synapse Cable)
Setting DEC VT220 / VT320 / VT420 Keyboard Wedge Synapse Cable Options (Continued) Advanced Features The advanced feature options allow you to store communication parameters for up to two applications. If you have already configured the scanner, all of the communication settings are stored as Parameter 1 settings (default setting). Using the advanced feature options, you can also create Parameter 2 settings. When using the scanner, scan the correct parameter setting bar code to configure the scanner for each application. To set Parameter Set 1 configuration: Configure the scanner communications as described in this chapter. Since Parameter Set 1 is the default you do not have to scan the Parameter Set 1 bar code. To change the Parameter Set 1 configuration after storing settings in Parameter Set 2, scan the Parameter Set 1 code and then change the communication parameters as necessary. To set Parameter Set 2 configuration: 1. Scan the Parameter Set 2 bar code. 2. Configure the scanner communication parameters as described in this chapter. To set defaults for a parameter set, scan the appropriate default bar code. The selections are:
• Set Defaults Current Parameter Set • Set Defaults Both Parameter Sets
Publication 2755-6.4
Page 80
Communication Setup (Synapse Cable)
5–19
Setting Scanner Emulation Synapse Cable Options This section defines the communication options available when the scanner is connected to this Scanner Emulation Synapse cable:
• Catalog No. 2755-HFC-SA1-01 Default Settings Scan the Set Scanner Emulation Cable Defaults bar code to set the Synapse cable to default settings. Refer to the table below for the default settings.
Parameter
Default Setting
Refer to Description on Page:
Programming Guide➀ Page Reference
Emulation
Standard
5–20
6-2
Leading Margin
80 Millisecond
5–20
6-3
Decode LED
Enabled
5–20
6-3
Emulation Timeout
3 Seconds
5–21
6-4
Polarity
Margin Low / Bar High
5–21
6-5
Unknown Characters
Send Bar Codes with Unknown Characters
5–21
6-5
Convert All to Code 39
Disabled
5–22
6-6
Code 39 to Code 39 Full ASCII
Disabled
5–22
6-6
Parameter Set
Parameter Set 1
5–23
6-7
➀ Programming Guide for 2-D Bar Code Scanners (Publication 2755-6.7)
Publication 2755-6.4
Page 81
5–20
Communication Setup (Synapse Cable)
Setting Scanner Emulation Synapse Cable Options (Continued) Emulation Select the type of emulation your decoder requires. The selections are:
• • • •
Standard Emulation (default) MSI Wand Emulation Texlon Wand Emulation Norand Wand Emulation
Variable Leading Margin Sets the leading margin for wand emulation. The leading margin can be varied to allow more time for the decoder to wake up before the bar code data is received. The selections are:
• 80 msec (default) • 140 msec • 200 msec Check for Decode LED When enabled (default), a transmission error occurs if the decode LED line from the host is not active.
Publication 2755-6.4
Page 82
Communication Setup (Synapse Cable)
5–21
Emulation Timeout Determines how long:
• the Synapse cable waits for the laser on signal from the scanner after the trigger is pulled. • the scanner waits for a decode LED (check if Decode LED is enabled). The options:
• • • • •
3 second timeout (default) 4 second timeout 5 second timeout 10 second timeout 30 second timeout
Polarity Sets the polarity of the wand emulation signal. The selections are:
• Margin Low / Bar High (default) • Margin High / Bar Low Unknown Characters Unknown characters are characters not recognized by the scanner. When Send Bar Codes with Unknown Characters is enabled, all decoded bar code data is transmitted except for the unknown characters. If this option is disabled, bar codes containing one or more unknown characters are not transmitted.
Publication 2755-6.4
Page 83
5–22
Communication Setup (Synapse Cable)
Setting Scanner Emulation Synapse Cable Options (Continued) Convert All to Code 39 When enabled, decoded data is converted and transmitted as Code 39 data. Note: ASCII from the scanner is transmitted as Code 39 data. Code 39 to Code 39 Full ASCII When enabled, Code 39 data is transmitted as Code 39 Full ASCII. The full ASCII option allows the scanner to output any ASCII character or control code (including non-printable characters). Refer to Appendix C for a list of the Code 39 Full ASCII codes.
Publication 2755-6.4
Page 84
Communication Setup (Synapse Cable)
5–23
Advanced Features The advanced feature options allow you to store communication parameters for 2 separate applications. If you have already configured the scanner, all of the communication settings are stored as Parameter 1 settings (default setting). Using the advanced feature options, you can also create Parameter 2 settings. When using the scanner, scan the correct parameter setting bar code for each application. To select and/or set Parameter Set 1 configuration: Configure the scanner communications as described in this chapter. Since Parameter Set 1 is the default you do not have to scan the Parameter Set 1 bar code. To change the Parameter Set 1 configuration after storing settings in Parameter Set 2, scan the Parameter Set 1 code and then change the communication parameters as necessary. To set Parameter Set 2 configuration: 1. Scan the Parameter Set 2 bar code. 2. Configure the scanner communication parameters as described in this chapter. To select and/or set defaults for a parameter set, scan the appropriate default bar code. The selections are:
• Set Defaults Current Parameter Set • Set Defaults Both Parameter Sets
Publication 2755-6.4