Page 70
Communication Setup (Synapse Cable)
5–9
Setting IBM PC Keyboard Wedge Synapse Cable Options This section defines the communication options available when the scanner is connected to one of these IBM AT/XT or PS/2 Keyboard Wedge Synapse cables:
• Catalog No. 2755-HFC-SP1-01 • Catalog No. 2755-HFC-SP2-01 Defaults Settings Scan the Set PC Wedge Synapse Cable Defaults bar code to set the synapse cable to default settings. The following table lists the default settings.
Default Setting
Refer to Description on Page:
Programming Guide ➀ Page Reference
Host
IBM PC/AT IBM PS/2-50, 55SX, 60, 70, 80
5–10
3-2
Country
North American
5–10
3-3
Bar Codes with Unknown Labels
Send Bar Codes With Unknown Characters
5–11
3-4
Intercharacter Delay
5 milliseconds
5–11
3-4
Parameter Set
Parameter Set 1
5–12
3-5
Parameter
➀ Programming Guide for 2-D Bar Code Scanners (Publication 2755-6.7)
Publication 2755-6.4
Page 71
5–10
Communication Setup (Synapse Cable)
Setting IBM PC Keyboard Wedge Synapse Cable Options (Continued) Host Selection Select the type of host the scanner will be communicating with. The selections are:
• • • •
IBM PC/AT , PS/2-50, 55SX, 60, 70, 80 (default) IBM PC/XT IBM PS/2-30 NCR 7052
Country Selection Select the country for the keyboard type the synapse cable is connected to. The selections are:
• • • • • • • •
North American (default) German French French International Spanish Italian Swedish British
Publication 2755-6.4
Page 72
Communication Setup (Synapse Cable)
5–11
Unknown Characters Unknown characters are characters not recognized by the scanner. When Send Bar Codes with Unknown Characters is enabled (default), all decoded bar code data is transmitted except for the unknown characters. If this option is disabled, bar codes containing one or more unknown characters are not transmitted. Intercharacter Delay Setting an intercharacter delay provides the host time to perform processing tasks between characters. The default is short delay (5 msec). The options are:
• Short 5 msec delay (default) • Medium 50 msec delay • Long 99 msec delay
Publication 2755-6.4
Page 73
5–12
Communication Setup (Synapse Cable)
Setting IBM PC Keyboard Wedge Synapse Cable Options (Continued) Advanced Features The advanced feature options allow you to store communication parameters for up to two applications. If you have already configured the scanner, all of the communication settings are stored as Parameter 1 settings (default setting). Using the advanced feature options, you can also create Parameter 2 settings. When using the scanner, scan the correct parameter setting bar code to configure the scanner for each application. To use and/or set Parameter Set 1 configuration: Configure the scanner communications as described in this chapter. Since Parameter Set 1 is the default you do not have to scan the Parameter Set 1 bar code. To change the Parameter Set 1 configuration after storing settings in Parameter Set 2, scan the Parameter Set 1 code and then change the communication parameters as necessary. To use and/or set Parameter Set 2 configuration: 1. Scan the Parameter Set 2 bar code. 2. Configure the scanner communication parameters as described in this chapter. To set defaults for a parameter set, scan the appropriate default bar code. The selections are:
• Set Cable Defaults Current Parameter Set • Set Cable Defaults Both Parameter Sets
Publication 2755-6.4
Page 74
Communication Setup (Synapse Cable)
5–13
Setting DEC VT520 Keyboard Wedge Synapse Cable Options This section defines the communication options available when the scanner is connected to this DEC Keyboard Wedge Synapse cable:
• Catalog No. 2755-HFC-SV2-01 Default Settings Scan the Set DEC VT 520 Keyboard Wedge Synapse Cable Defaults bar code to set the Synapse cable to default settings. Refer to the table below for the default settings.
Parameter
Default Setting
Refer to Description on Page:
Programming Guide➀ Page Reference
Host
DEC VT520
5–14
4-2
Country
North American
5–14
4-2
Unknown Characters
Send Bar Codes With Unknown Characters
5–14
4-4
Intercharacter Delay
5 Millisecond
5–14
4-4
Parameter Set
Parameter Set 1
5–15
4-5
➀ Programming Guide for 2-D Bar Code Scanners (Publication 2755-6.7)
Publication 2755-6.4
Page 75
5–14
Communication Setup (Synapse Cable)
Setting DEC VT520 Keyboard Wedge Synapse Cable Options (Continued) Host Selection Select the type of host the scanner will be communicating with. The selections are:
• DEC VT520 (default) • DEC VT520 with PS/2 Keyboard Country Selection Select the country for the keyboard type the Synapse cable is connected to. The selections are:
• • • • • • • •
North American (default) German French French International Spanish Italian Swedish British
Unknown Characters Unknown characters are characters not recognized by the scanner. When Send Bar Codes with Unknown Characters is enabled (default), all decoded bar code data is transmitted except for the unknown characters. If this option is disabled, bar codes containing one or more unknown characters are not transmitted.
Publication 2755-6.4
Page 76
Communication Setup (Synapse Cable)
5–15
Intercharacter Delay Some devices require a delay between characters to simulate the effect of keystroke delays (characters are sent at a lower rate). The default is short delay (5 msec). The options are:
• Short 5 msec delay (default) • Medium 50 msec delay • Long 99 msec delay Advanced Features The advanced feature options allow you to store communication parameters for up to two applications. If you have already configured the scanner, all of the communication settings are stored as Parameter 1 settings (default setting). Using the advanced feature options, you can also create Parameter 2 settings. When using the scanner, scan the correct parameter setting bar code to configure the scanner for each application. To set Parameter Set 1 configuration: Configure the scanner communications as described in this chapter. Since Parameter Set 1 is the default you do not have to scan the Parameter Set 1 bar code. To change the Parameter Set 1 configuration after storing settings in Parameter Set 2, scan the Parameter Set 1 code and then change the communication parameters as necessary. To set Parameter Set 2 configuration: 1. Scan the Parameter Set 2 bar code. 2. Configure the scanner communication parameters as described in this chapter. To set defaults for a parameter set, scan the appropriate default bar code. The selections are:
• Set Defaults Current Parameter Set • Set Defaults Both Parameter Sets Publication 2755-6.4
Page 77
5–16
Communication Setup (Synapse Cable)
Setting DEC VT220 / VT320 / VT420 Keyboard Wedge Synapse Cable Options This section defines the communication options available when the scanner is connected to this DEC Keyboard Wedge Synapse cable:
• Catalog No. 2755-HFC-SV1-01 Default Settings Scan the Set DEC VT 20/320/420 Wedge Synapse Cable Defaults bar code to set the Synapse cable to default settings. The table below lists the defaults.
Parameter
Default Setting
Refer to Description on Page:
Programming Guide ➀ Page Reference
Host
DEC VT220 / 320
5–16
5-2
Country
North American
5–17
5-2
Unknown Characters
Send Bar Codes With Unknown Characters
5–17
5-4
Intercharacter Delay
5 Millisecond
5–17
5-4
Parameter Set
Parameter Set 1
5–18
5-5
➀ Programming Guide for 2-D Bar Code Scanners (Publication 2755-6.7)
Host Selection Select the type of host the scanner will be communicating with. The selections are:
• DEC VT 220/320 (default) • DEC VT420