Page 41

Maintenance and Troubleshooting This chapter provides information on how to maintain and troubleshoot your StrataScan hardware. Items include: • cleaning the scan window • troubleshooting the readers • contacting Technical Support

! Cleaning the Scan Window

CAUTION!: Before cleaning window, make sure that power to the reader is off. Failure to disconnect power may cause exposure to laser light.

Carefully clean the window by first removing loose particles of dirt with canned ultra–filtered air. Then use an optical quality cloth moistened with an optical quality cleaning fluid for plastic lenses. Wipe the window in a single direction, turning the cloth to a clean side after each wipe(don’t wipe cloth back and forth across window). Do not leave streaks.

!

!

ATTENTION: Do not use abrasive materials such as disposable wipes and facial tissue. Do not use solvents like alcohol or acetone. These materials will damage the window and the finish on the reader.

ATTENTION: The reader has no serviceable parts. Do not open the housing of the reader.

Publication 2755-6.13

Page 42

5–2

Maintenance and Troubleshooting

Troubleshooting the Readers

The following table provides a list of the most common operating problems, probable causes, and corrective actions.

Problem No blinking Green LED

Possible Cause (s) No power

Corrective Action

No Motor Spin

No power

Blinking Green LED

Motherboard problem

No Motor Spin

1. Motherboard problem

Contact an Allen–Bradley service representative.

2. Reader is in motor failure condition. 1. Motor may be defective.

Contact an Allen–Bradley service representative①.

Check transformer, outlet and power strip.

LED’s toggle back and forth and unit produces “razzes”

2. Too much vibration or jarring Decode module failed communications with the motherboard

Isolate reader from vibration.

Power-up OK, reads OK but does not communicate properly to host.

COM Port at host not working or is configured improperly

As a quick test, put reader into Program mode through StrataScan software. If successful, the RECEIVE and TRANSMIT lines are working②.

Does not communicate properly to host

Cable not connected to the proper COM Port

Check cable connections.

Reader makes “razz” tone during power-up

①

②

Contact an Allen-Bradley service representative.

If reader is in an environment subject to much vibration or sudden jarring, the motor may experience a motor failure condition temporarily. The unit will recover after the external stimulus has disappeared. If the reader is not configured for host RTS/CTS, this test is enough to verify that the reader, communication cable and host are all working properly. When the reader is configured for host RTS/CTS, temporarily disable this function in the reader and try the quick test above. If the reader works with RTS/CTS disabled, and fails when RTS/CTS is re–enabled, there is a problem with either the RTS or CTS line or both. Contact an Allen–Bradley service rep.

Table continued on the next page.

Publication 2755-6.13

Page 43

Maintenance and Troubleshooting

Problem

Reader does not enter Program mode

Possible Cause (s)

5–3

Corrective Action

1. Host COM Port not working properly

1. Check to see if cable connection to COM Port is correct.

2. Wrong COM Port

2. Make sure COM Port selection in StrataScan configuration software is correct.

3. Communication cable is not connected properly or is defective Host receiving data but data does not look correct

Interface format incompatibility

Check that the reader and host are configured for the same interface format.

Characters are being dropped

No inter–character delay

Add some inter–character delay to the transmitted output. Program this into reader through the StrataScan configuration software.

Unit powers up properly and lasers come on, but still does not read.

Reading a particular symbology that has been deselected.

Verify that the bar code being read is selected.

Reader has been programmed for a character length lock or for a minimum length and the bar code being read does not satisfy the programmed criteria.

Verify that bar code being read falls into the criteria.

Reader has been configured for Package Detect Support, but is not receiving a Package Detect signal

Verify that the device used to generate the package detect input is working properly.

Reader reads and transmits a bar code, but the reader hangs up (green LED comes on and stays on) after the first read. The reader is configured to support some form of host handshaking, but is not receiving the signal. If the reader is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E.

Verify that host is supporting the handshaking properly.

Package Detect is selected and the Package Detect signal seems to be generated properly, but the reader is not reading.

Read duration may be set too short. Read duration can be set from 100 msec to 8.9 sec. Make sure that read duration time is set correctly for the particular application.

Reader reads and transmits, but the data is not correct at the host.

Verify that reader’s data format matches that required by the host. Make sure that the reader is connected to the proper host port. As a rule of thumb, if configurations can be downloaded successfully to the reader, the cable and port setup are physically working. The only exception is with RTS/CTS, which is not used during the download sequence.

Table continued on the next page.

Publication 2755-6.13

Page 44

5–4

Maintenance and Troubleshooting

Problem

Possible Cause (s) 1. Print quality of the bar code is suspect.

Cannot read bar code➂

2. The aspect ratio of the bar code is out of tolerance.

3. The bar code may have been printed incorrectly.

DOS error code: # 68 – Device unavailable

DOS error code: # 24 – Device timeout

➂

Corrective Action To verify the basic operation of the reader, configure the reader with the standard default settings. To do this, enter the reader’s Program Mode from StrataScan’s main menu. Press Enter at the Configuration screen menu choice. From the Configuration screen, press F5 to download the configuration to the reader. The reader is now setup to read all common symbologies with a minimum of 4 characters. Try reading a typical UPC bar code on a typical office supply product or food product. If the reader reads the bar code presented, the basic operation of the reader is verified. The problem is within the reader setup. Determine how the reader should be configured. Contact an Allen–Bradley service rep. for help. If not possible, then make sure all settings are correct.

This error occurs when a file or COM Port is accessed (that according to the system) does not exist. Normally this occurs when the COM Port is used that is attached to a wrong type of peripheral. Or when there is a problem with the COM Port itself.

Try using another COM Port, if available. If all else fails, reboot the system.

This error occurs when the host did not receive information from the I/O device within a predetermined amount of time.

Check that the reader is connected to the correct COM Port and verify that the COM Port is working correctly. If all else fails, reboot the system.

Many other scenarios can cause reading problems. If problems persist, contact an Allen–Bradley service representative.

Publication 2755-6.13

Page 45

Maintenance and Troubleshooting

Technical Support Services

5–5

If you have any questions about the StrataScan Bar Code Reader, please consult this manual first. If you can’t find the answer, contact your local Allen-Bradley support office or distributor.

Publication 2755-6.13