Page 22
Designing Your System This chapter provides the information needed to set up a scanner system correctly. Items include: • setup goals • symbol height and length • symbol quality • symbol orientation • tilt, pitch, and skew • determining read range
Setup Goals
Each application must be evaluated carefully. Successful bar code scanning begins with quality bar code symbols and the correct number, type, and location of readers, decoders, and package sensors. Refer to the following when designing your scanner system. • Adjust, if necessary, the symbol speed and/or the distance between bar-coded packages to ensure that the bar code symbol is being read. • Position the reader at a distance from the symbol that is within the range specified. A read rate test should be made to verify the range, and also to ensure optimum scanning and decoding. • If a package sensor is used, position it so it can sense the package before the symbol reaches the scan area.
Publication 2755-6.13
Page 23
3–2
Designing Your System
Symbol Height and Length
The height is measured from one end of a bar to the other, and its length is always the distance from one end of the symbol to the other, including the Quiet Zones. A Quiet Zone is the empty space before or after the bars, and is usually equal to 10 times the Narrow Element Width. H
Symbol Length = L
Symbol Height = H
Quiet Zones
L
Quiet Zones
The aspect ratio (symbol height to symbol length) cannot be greater than 1.7:1 for Catalog No. 2755-LHR-3C and 2.5:1 for Catalog No. 2755-LHR-5C.
Symbol Quality
A bar code reader cannot reliably read a poor quality symbol. Test proposed bar code symbol samples to ANSI Standard X3.182-1990, Bar Code Print Quality Guideline. • Low-cost verifiers that can test this standard are available from several companies. • Symbol samples can be submitted to an independent symbology testing company. The ANSI guideline specified six parametric tests plus two pass/fail tests to determine the printed symbol quality. The tests result in an overall letter grade of A, B, C, D or F assigned to the symbol. In general, symbols are most decodable in the A range with diminishing quality through F. An F or failure occurs because a symbol does not conform to a legitimate bar code symbology, whereas a D grade has a better chance of being read. And a C has a still better chance of being read by more readers than a D. And so on.
Publication 2755-6.13
Page 24
Designing Your System
Symbol Orientation
3–3
Bar code symbols must have the correct aspect ratio to be read by the reader. A scan line must cross every bar, space, and both quiet zones on the same sweep.
Correct: All bars are crossed by a scan line
Not Correct: Some bars are not crossed by a scan line
Tilt, Pitch, and Skew
Refer to the figure below for various package orientations. Tilt, pitch, and skew can affect the scan aspect ratio, and as a result, can affect the reader’s ability to read bar code symbols. reader Skewed Package and Symbol
Pitched Package and Symbol Tilted Symbol Correctly Positioned Symbol and Package
Publication 2755-6.13
Page 25
3–4
Designing Your System
Tilt A symbol is tilted when the symbol’s bars are not 90° to one of the scan lines. The symbol can be read with any tilt, provided a scan line passes through all bars and quiet zones on each sweep for the required minimum number of scans. Tilt may reduce the number of scans in a given application.
Pitch A symbol is pitched when the symbol’s bars are at different distances from the reader. From the reader’s perspective, a pitched symbol appears to have a smaller narrow element width than it actually has. This may reduce both the read rate and the read range. However, the symbol can still be read if the apparent narrow element width is within the reader’s specifications.
Skew A symbol is skewed when the ends of the symbol’s bars are not at the same distance from the reader. The symbol can be read if the distance of both ends of the bar are within the reader’s read range, and the skew is less than degrees from the centerline. Unlike pitch, skew does not affect the read range.
Publication 2755-6.13
Page 26
Designing Your System
Determining Read Range
3–5
The readers can read bar code symbols at various distances depending upon the type of reader and the narrowest bar code element width (width of smallest bar or space).
Catalog Number
Minimum Bar Code Width
2755-LHR-5B
0.008 in. (0.20 mm)
18 to 38 in. (45.7 to 96.5 cm)
12 in. (30.5 cm)
0.025 in. (0.64 mm)
18 to 38 in. (45.7 to 96.5 cm)
12 in. (30.5 cm)
0.013 in. (0.33 mm)
36 to 78 in. (91.4 to 198.1 cm)
22 in. (55.9 cm)
0.04 in. (1.02 mm)
36 to 78 in. (91.4 to 198.1 cm)
22 in. (55.9 cm)
0.013 in. (0.33 mm)
34 to 64 in. (86.4 to 162.6 cm)
22 in. (55.9 cm)
0.04 in. (1.02 mm)
36 to 78 in. (91.4 to 198.2 cm)
22 in. (55.9 cm)
0.008 in. (0.20 mm)
33 to 43 in. (83.8 to 109.2 cm)
13 in. (33.0 cm)
0.025 in. (0.64 mm)
33 to 43 in. (83.8 to 109.2 cm)
13 in. (33.0 cm)
2755-LHR-3C 2755-LHR-5C 2755-LHR-5BX1
Maximum Scan Width
Read Range
Catalog Number 2755-LHR-5B
Catalog Number 2755–LHR–5BX1
Scanner
Scanner
Distance From Front of Scanner
Distance From Front of Scanner
0 in. (0 cm)
0 in. (0 cm)
18 in. (45.7 cm)
33 in. (83.8 cm)
38 in. (96.5 cm)
43 in. (109.2 cm)
Scan Width
Scan Width
12 in. (30.5 cm)
12 in. (30.5 cm)
Catalog Numbers 2755-LHR-3C and 2755-LHR-5C Scanner Distance From Front of Scanner 0 in. (0 cm)
34 in. (86.4 cm) 36 in. (91.4 cm)
64 in. (162.6 cm) 78 in. (198.2 cm)
Scan Width 24 in. (61 cm)
Publication 2755-6.13