Page 7

Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option

DEC VT100 Terminal

If using a DEC VT100 terminal: 1. Construct a cable to connect the VT100 to the decoder. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type or 25-Pin Connector

Decoder AUX Port

NEMA Type 4

NEMA Type 1

C

2

Transmit Data

2

B

3

3

D

7

Receive Data Signal Ground

25-pin Female

Terminal

7

Note: Connect shield to shell of cable connectors at both ends.

2. Plug terminal into power supply. 3. Power on terminal. 4. Enter Set-Up B on terminal. The following figure shows one setup. SETUP B

TO EXIT PRESS ”SET-UP”

1 0101

2 0011

1 . . 01

3 0000

4 0010

2 . . 11 Cursor Block Screen Dark Don’t Care Don’t Care

T SPEED 9600

R SPEED 9600

3 . 00 . XON/XOFF ON ANSI Don’t Care Don’t Care

4 . 010 Don’t Care New Line Off Wrap Off Don’t Care

60 Hz 8 Bits Parity Off Don’t Care

7

Page 8

Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option

1784-T45 Programming Terminal

Follow these steps if using an Allen-Bradley 1784-T45 terminal: 1. Construct a cable to connect the terminal to the decoder. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type or 25-Pin Connector

Decoder AUX Port

NEMA Type 4

NEMA Type 1

C

2

Transmit Data

2

B

3

3

D

7

Receive Data Signal Ground

25-pin Female

4

. Note: Connect shield to shell of cable connectors at both ends.

5

CTS RTS

6

DSR

Terminal

7 8

CD

20 DTR

2. Power on the terminal. The switch is located on the left side of the unit. The terminal will beep once, and then test itself. When the test is complete, a message appears. The last line should indicate that all tests have passed. 3 Press [CTRL][ALT][CMD] key sequence to display the Main Menu (Press the [CMD] key while holding down the [ALT] and [CTRL] keys. 4. Set the -T45 terminal emulation to the following settings (Refer to the terminal documentation for additional information):

• F1 DGC D200 Terminal • F2 Modem = External • F3 Flow Control = On • F4 Duplex = Full • F6 Print = Off 5. Set the COM1 parameters to:

• F1 Baud Rate = 9600 • F2 Parity = None • F3 Data Bits = 8 • F4 Stop Bits = 1 • F5 Type = Standard PC Compatible Com Note: If using an internal modem, disable it using the MODE command. 6. When the Select CRT Type menu appears, select Data General DT100 emulation. 8

Page 9

Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option

1784-T47 Programming Terminal

Follow these steps if using an Allen-Bradley 1784-T47 terminal: 1. Construct a cable to connect the -T47 terminal to the decoder. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type or 25-Pin Connector

Decoder AUX Port

NEMA Type 4

NEMA Type 1

C

2

Transmit Data

2

B

3

3

D

7

Receive Data Signal Ground

25-pin Female

4

. Note: Connect shield to shell of cable connectors at both ends.

5

CTS RTS

6

DSR

Terminal

7 8

CD

20 DTR

2. Apply power to the -T47 terminal and run your terminal emulator with the following Com 1 or 2 parameters: Baud Rate = Parity = Data Bits = Stop Bits =

9600 None 8 1

9

Page 10

Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option

1770-T1, -T2, -T3 Terminals

Follow these steps if using an Allen-Bradley 1770-T1, -T2, or -T3 terminal: 1. Construct a cable to connect the decoder to Channel B of the terminal. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type or 25-Pin Connector NEMA Type 4

NEMA Type 1

2

Transmit Data

B

3

D

7

Receive Data Signal Ground

C Decoder AUX Port

25-pin Male

2

. .

3

Terminal

7 18 25

Note: Connect shield to shell of cable connectors at both ends.

2. Plug terminal into power supply. 3. Install the alphanumeric keypad overlay on the terminal keyboard. 4. Power on terminal. Enter 12 to select alphanumeric. 5. Select Alphanumeric Mode and set the following parameters (refer to your terminal documentation for additional information): Baud Rate = Parity = Stop Bits = Channel Config. = Duplex = Channel C = Cursor = Auto Line Feed after Return = Control Code Display =

9600 None 1 B IN/OUT Full On or Off On Off Off

Note: Use the <CTRL> and U, D, L, or R keys for Up, Down, Left and Right cursor movement.

10

Page 11

Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option

2708-DH5 Attended Workstations

Follow these steps if using one of the Allen-Bradley 2708-DH5 Attended Workstations: 1. Construct a cable to connect the decoder to the COM1 port of the 2708-DH5 terminal. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type or 25-Pin Connector

Decoder AUX Port

NEMA Type 4

NEMA Type 1

9-pin Female

C

2

3

B

3

2

D

7

5

Terminal

2. Plug terminal into power supply. 3. Power on terminal. 4. Select Network Menu (option 1) and set the following parameters: Terminal Number = 0 Terminal Type = Normal

The rest of the network parameters are not applicable. 5. Select Comm Port Menu (option 2) and set the following parameters: Comm Mode Comm Baud Rate = Comm Data Bits = Comm Parity = Comm Stop Bits = Comm CRLF = Comm Echo = Comm Handshake =

XON/XOFF 9600 8 None 1 Disabled Disabled Disabled

The rest of the parameters are not applicable. Note: BASIC code does not have to be written in the DH5 Attended Workstation in order to use it as a dumb terminal.

11

Page 12

Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option

Running the Application

To run the application, follow these procedures: 1. Be sure that the terminal emulator or dumb terminal is connected to the decoder auxiliary port. 2. Begin entering data at your terminal. You should see the information on your display screen. (Echo to terminal = YES) 3. Data is now transmitted through the decoder to the host device.

Host Device

Dumb Terminal Auxillary Port Host Port

Decoder

Note: If you are interfacing a decoder with a PLC host, refer to the related publications list on page 2.

Allen-Bradley has been helping its customers improve productivity and quality for 90 years. A-B designs, manufactures and supports a broad range of control and automation products worldwide. They include logic processors, power and motion control devices, man-machine interfaces and sensors. Allen-Bradley is a subsidiary of Rockwell International, one of the world’s leading technology companies.

With major offices worldwide. Algeria • Argentina • Australia • Austria • Bahrain • Belgium • Brazil • Bulgaria • Canada • Chile • China, PRC • Colombia • Costa Rica • Croatia • Cyprus • Czech Republic • Denmark • Ecuador • Egypt • El Salvador • Finland • France • Germany • Greece • Guatemala • Honduras • Hong Kong • Hungary • Iceland • India • Indonesia • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Malaysia • Mexico • New Zealand • Norway • Oman • Pakistan • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia-CIS • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic • Spain • Switzerland • Taiwan • Thailand • The Netherlands • Turkey • United Arab Emirates • United Kingdom • United States • Uruguay • Venezuela • Yugoslavia World Headquarters, Allen-Bradley, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Publication 2755-2.49 -July 1994

12

Copyright 1994 Allen-Bradley Company, Inc. Printed in USA