The text of a manual · part 1 of 2
Bulletin 2755 Enhanced Bar Code Decoder Pass-Through Option Application Note, pages 1 to 6
Pages 1 to 6 of 12
The original document is the PDF (78 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-DS
Page 1
ALLEN-BRADLEY
A–B
Bulletin 2755 Enhanced Bar Code Decoder Pass-Through Option Application Note
Overview
This document describes how use the manual data entry Pass-Through function of an enhanced decoder. The Pass-Through function allows communications between a data entry terminal and a host device by passing information directly through the enhanced decoder. The operation works as follows: 1. Operator enters data at the terminal keyboard. 2. Information is transmitted through the decoder auxiliary port and out the host port to a host device.
Terminal Device AUX Port
Host Port
Data Pass-Through
Enhanced Bar Code Decoder
Host Device
For reference, this document also contains:
• Connection diagrams • Enhanced Decoder information
Page 2
Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option
Hardware Requirements
A typical data pass through application requires the following hardware:
• 2755-DD/DS (Series A, Rev A) or greater enhanced decoder • Dumb terminal or PC with terminal emulation software • Cabling (See pages 6 to 10) You also need a dumb terminal or a computer with terminal emulator software to configure the decoder. The dumb terminal can also be used to enter data into the system.
Related Publications
For additional information, refer to the following Allen-Bradley publications: Publication Number 2755-ND011/ND012 2755-833 2755-2.54
2
Title Bulletin 2755-DS/DD Series A Enhanced Decoder User Manual Bulletin 2755-DS/DD Series B Enhanced Decoder User Manual Interfacing a 2755-DS/DD Bar Code Decoder to a PLC-5 Using RS-232/ASCII Protocol with the 2760-RB Module and Either the 2760-SFC1 or -SFC2 Protocol Cartridge.
2755-2.55
Interfacing a 2755-DS/DD Bar Code Decoder to a PLC-5 Using DH485 Protocol With 2760-RB Module and the 2760-SFC Protocol Cartridge
2755-2.58
2755-DS/DD Bar Code Decoder Interfacing to new Platform PLC-5
Page 3
Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option
Decoder Configuration
Connect the system as shown below with the dumb terminal connected to the auxiliary port of the decoder. Auxillary Port
To Host Device Host Port
Decoder
Dumb Terminal
Note: The hardware/software handshaking to the Host port of the decoder is not reflected to the AUX port. Cycle power on decoder. If connected to a terminal emulator, the first menu screen, Select Language should appear. 1. Enter the appropriate options for the Select Language and Select CRT Type screens. 2. After selecting the terminal type, the Select Operation Screen appears. Function 8 on the Select Operation Screen accesses the AUX Terminal Data Entry Screen used to configure the AUX terminal for manual data entry operations. Enter the following parameters on this screen.
3
Page 4
Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option
3. Function 7 on the Select Operation Screen accesses the Host Communications Screen. Enter the following parameters into this screen.
4. Save the new configuration to EPROM and restart the decoder.
4
Page 5
Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option
Switching to Manual Data Entry Mode
The AUX port of the decoder communicates with a standard ASCII terminal through an RS-232 interface. This terminal is referred to as the AUX terminal. The AUX port can switch between two mutually exclusive modes of operations, decoder configuration and manual data entry. To enable the AUX terminal for manual data entry, as needed for the Pass-Through function, follow the instructions below: 1. Turn power off to decoder. 2. Open the face cover of the decoder to reveal the main logic board. The Internal Selector is a jumper on the main logic board, labelled AUX Terminal. See diagram below: Internal Selector (AUX Terminal Jumper) Internal Selector
AUX TERMINAL
∨∨ LCD DISPLAY CONTRAST ADJUST
DATA CONFIG. ENTRY
Enclosure Main Logic Board
The jumper has two positions, which determine the mode of operation that is enabled for the AUX port terminal. AUX TERMINAL
∨∨ DATA CONFIG. ENTRY
AUX TERMINAL
∨∨ DATA CONFIG. ENTRY
Default Setting
CONFIG (Jumper Open) With the jumper open (as shown on the left) you can use the AUX terminal for configuration only. Configuration menus and screens are enabled. This is the factory default setting. DATA ENTRY (Jumper Closed) With the jumper closed (as shown on the left) you can use the AUX terminal for manual data entry and display functions only. Configuration menus and screens are disabled. 3. Switch the Internal Selector to the left most position on data entry. This will allow communications through the decoder, through the interface module to the PLC data table. 5
Page 6
Application Note Bulletin 2755 Enhanced Decoder Pass-Through Option
Terminal Setup
This section provides instructions on how to setup and connect the following terminals to the AUX port of the NEMA Type 1 or Type 4 decoder.
• Lear Siegler ADM 3E / Wyse Terminals • DEC VT100 • 1784-T45 • 1771-T1, -T2, -T3 • Bulletin 2708 DH5 Workstations Lear Siegler / Wyse Terminal
If using a Lear Siegler ADM 3E terminal or Wyse terminal: 1. Construct a cable to connect the terminal to the decoder. Use a Belden 8303, Alpha 45123, or equivalent type of cable. Use the following connector pinouts: Male 19-pin NEMA Type or 25-Pin Connector NEMA Type 4
Decoder AUX Port
NEMA Type 1
25-pin Male
C
2
Transmit Data
B
3
D
7
Receive Data Signal Ground
2 3
Terminal
7
Note: Connect shield to shell of cable connectors at both ends.
2. Plug terminal into power supply. 3. Power on terminal. 4. Press [Shift] [SETUP] to enter setup mode. 5. Use the arrow keys to set the following parameters on the terminal:
• Full Duplex (FDX) • 9600 Baud Rate • 8 Data Bits per Character • No Parity • XON/XOFF Flow Control or Handshake • Blinking Block Cursor 6. To save the selected parameters, press [Ctrl] [S]. 7. Exit setup mode by pressing [Shift] [SETUP].
6