Configuration Menus Introduction
The workstation uses menus to make configuration parameters accessible and easy to change. They were designed to be entered, changed and exited by pushing various keys on the keypad. It is also possible to access the menus through the communications port using host commands. See section “Menu 2: Comm Port Menu Parameters”.
Using Menus via Workstation Keypad
In order to access the menus, press the menu trigger keys (Enter and Right Arrow simultaneously). If a program is loaded, the trigger keys must be held down while power is removed and then reapplied. The first menu is the Network Menu and it looks like the display in Figure 5.1. Figure 5.1 Network Menu
1–Network Menu < for next menu When the IN key is pressed, it will allow you to scan the six major menus, one at a time. They are: 1. Network Menu 2. Comm Port Menu 3. System Menu 4. Bar Code Menu 5. Read Only Menu 6. Diagnostics Menu From the Diagnostics Menu, pressing <IN> one more time will cause the Network Menu to reappear. By pressing <OUT> you can scan backwards or you can select the desired menu by pressing the appropriate menu number. For example, if the Comm Port Menu is showing on the display, you can get to the Diagnostics Menu simply by pressing the <6> key. The Diagnostics Menu will now appear on the display.
5–1
Page 43
Chapter 5 Configuration Menus
Using Menus via Sub-Menus Workstation Keypad (cont’d)
After you have selected the appropriate menu item, you can now examine the sub-menu by pressing <ENTER>. With the exception of the Diagnostic Menu (which is discussed later), you can scan through the list of parameters by pressing <ENTER>, and scan backwards by pressing <CLEAR>. The parameter which appears on the display is the one which is selected. Once a parameter is selected, it may be changed. The settings or options suitable for that parameter can be examined/changed by pressing <LEFT ARROW>. For some parameters, this is a numeric item which requires that you enter a value in order to modify it. Once the parameter has been changed, you must press <ENTER> for the parameter to be accepted. If you press <EXIT> or <CLEAR> without having pressed <ENTER>, you selection will be ignored. Note: Once you have entered the diagnostics menu (by pressing <ENTER> from the 6-Diagnostics menu) use <LEFT ARROW> to move through and select the diagnostic you want to execute. Press <ENTER> to start the diagnostic. Most diagnostics can be stopped by pressing <EXIT>. Pressing <EXIT> from any of the parameters will return the unit to the Network Menu (Figure 5.1).
Exiting Network Menu Pressing <EXIT> from the Network Menu will exit the menus completely. First, “Final Exit” (Figure 5.2) will briefly appear on the display, to be replaced either by the status display, or in the case where a program has been already placed into the workstation, program run will begin. Figure 5.2 Final Exit Menu
Final Exit.
5–2
Page 44
Chapter 5 Configuration Menus
Using Menus from the Comm Port
After you have attached the cable from the COM1 or COM2 port on a Master workstation to the appropriate port on your PC or Host, you must transmit a control character sequence from the communication port menu (see section titled “Menu 2: Comm Port Menu Parameters”). This is typically done by holding down the Control (Ctrl) key and pressing the appropriate letter key (T, C, O, or N) at the same time. Note: The factory default configuration of the COM1 and COM2 ports is 9600 baud, 7 data bits, EVEN parity and 1 stop bit. The workstation will also ECHO each character it receives. The following should appear on your PC: Figure 5.3 Menu Mode
––––Menu Mode–––– Use Backspace to select Use Return for next item Use Control-Z to exit 1–Network Menu If the workstation does not show the text in Figure 5.3, then you should check to make sure: 1. The cabling is correct. 2. Your workstation baud rate matches that of the host. 3. The workstation has not been configured as a Concentrator, Submaster or Alternate Submaster. 4. A control character, such as Control-T, is selected to enter the menus from the comm port. Check the Comm Menu Character in the comm port menu. The <BACKSPACE> and the <SPACE> key will allow you to select one of the following menus: 1–Network Menu 3–System Menu 5–Read Only Menu
2–Comm Port Menu 4–Bar Code Menu 6–Diagnostics
When you have selected the menu you want, press the <ENTER> key on your workstation. Each time you press <ENTER>, the display will skip down to another parameter in the menu. Holding down the <CTRL> and pressing <Z> (referred to as < ^Z>) will exit from the menu back to the 1–Network menu. Exiting from the Network menu with the < ^Z> will display: Final Exit.
The workstation will then continue its normal operation. 5–3
Page 45
Chapter 5 Configuration Menus
Using Menus from the Comm Port (cont’d)
Notice that the selection of a parameter can be managed by scanning through the parameters using <backspace> or <space>. Also, the number or letter of the parameter you wish to invoke can be entered directly. In the case of the Diagnostics, this can be particularly helpful due to the large number of Diagnostics available. Pressing <LEFT ARROW> will back through the parameters. Note: To enable a parameter, you must press <ENTER> in order for your selection to actually take place. Pressing < ^Z> or <DELETE> will cause your selection to be ignored.
Menu 1: Network Menu Paramters
The following is a description of those parameters accessed by pressing <ENTER> when 1–Network Menu is showing on the display. Workstation Setting terminal to zero (0) turns the workstation into a dumb terminal (“standalone mode”). Normally a workstation will be configured as number 1-99. The terminal number (I.D. number) is 0 only when the workstation is used in standalone mode. A value between 1 and 99 must be used for the workstation to operate on a network. Note: The selected workstation number must be different from the other terminals on the network. Two workstations cannot have the same terminal number. Workstation Type The six possible workstation types are:
5–4
Normal Master Alternate Concentrator Submaster Alternate Submaster Gateway
Standard Workstation Communicates with Host via the Com1 port Backup for the Master Connects Submaster to backbone network Connects tributary to Concentrator Backup for Submaster Master/Concentrator
Lower Poll Addr (1 - 99) –
This value is set on each Concentrator/Master workstation and specifies the lowest unit number that the Concentrator or Master should attempt to locate. It is used to expedite bringing units online in small network environments.
Host Port (COM or AUX)
Select which port will communicate with the host device.
Page 46
Chapter 5 Configuration Menus
Menu 1: Network Menu Paramters (cont’d)
Upper Poll Addr (1 - 99) –
This value is set on each Concentrator/Master unit and specifies the highest unit number plus 1, that the Master or Concentrator should attempt to locate when bringing units online. It is used to expedite accommodation of workstations coming online in a small network environment.
Offline Cycle (normally 40) – This value is set on each Concentrator/Master workstation and gives the number of online unit polls which will be performed before an attempt is made to find an offline workstation. Larger values will initiate fewer polls for offline workstations. Max Net Retries (1 - 999) –
This value is set on each Concentrator/Master workstation and is the number of times that the Concentrator/Master will retry a failed poll before designating the workstation offline.
Comm Mode –
The following communication protocols are selectable: XON/XOFF DSR Polled Request
Menu 2: Comm Port Menu Parameters
The following is a description of those parameters accessed by pressing <ENTER> when 2–Comm Port Menu is showing on the display. Comm Port Mode The four parameters available are: The data collection software you use on your Host will determine which comm port mode to use. (If you are using the Network Manager Software package (Catalog No. 2708-NNM), set the comm port mode to POLLED.) XON/XOFF
Use Control-Q (XON) and Control-S (XOFF). In this mode, the Master sends the data records to the Host as they are collected. Records are sent from the workstation even if there is a problem with the Host, or no Host exists. Note: If the host is not ready to receive the data, the data will be lost.
DSR
Lower DSR to stop transmissions. 5–5
Page 47
Chapter 5 Configuration Menus
Polled
The workstation transmits only when polled. However, if DSR or Polled mode are selected, XON/XOFF will also be honored by the workstation.
Request
This mode does error checking and retransmission of all data blocks. It is intended for electrically noisy environments.
Comm Baud Rate The following baud rates are available: 19200 1200 9600 600 4800 300 2400 150 75 Comm Data Bits The parameters are 7 to 8. Comm Parity Your choice of parities for 7 data bits are: Even Odd None Zero Mark Your choice of parities for 8 data bits are: Even Odd None Comm Stop Bits – Parameters available are: One Two One and a half
5–6
Comm CRLF
Parameters are Enabled or Disabled. When enabled, the workstation will send a line-feed after each carriage return that it transmits.
Comm Echo
The choices are Enabled or Disabled. When enabled, the workstation will echo each character it receives from the comm line back to the communications line. This must be disabled when communicating with most Host computers.
Sync Count
When 0, asynchronous communication is enabled on the COM1 port. This should always be left at 0 (zero).
Page 48
Chapter 5 Configuration Menus
Aux Baud Rate for COM2 – The following baud rates are available: 38400 19200 9600 4800 2400
1200 600 300 150 75
Aux Parity For COM2 – Parity choices are: Even Odd None Zero Mark Aux CRLF For COM2 – Parameter choices are: Enable Disable Aux Echo For COM2 – Parameter choices are: Enable Disable Comm Menu char – Parameter choices for enabling menu configuration from a host computer are: ^T ^C ^O ^N NONE [Default] This parameter specifies the character that is used from the comm ports to enter the menu mode. NONE is the default. If the selected character conflicts with the data transmission between the Host and the Master workstation, then it may be necessary to select another character to be used to signal the workstation to enter the menus. When the NONE option is selected, it is not possible to enter the menus from the comm ports, nor is it possible to reboot the workstation with the ^R character.
5–7
Page 49
Chapter 5 Configuration Menus
Menu 3: System Menu Parameters
Time (hhmmss) Current time – This is one method of setting time in the workstation. Notice that the time shown is the time the menu was entered. Date (yymmddw) Current date – This is one method of setting the date and day of week in the workstation. The date must be entered in year, month, and date order. The “w” represents the day of the week. (Sunday = 1 through Saturday = 7). Menu Password 0-9999 – When this is non-zero, the workstation user will be required to enter this value before access to the menus is allowed. Note: For added security, the user will be shown prompts for a 5–digit password, even though only four digits configured are entered. Clock Mode 1 - 35 (normally 7) – This is a value which contrtols the format of the time on status displays. This does not affect the BASIC “Time$” variable. See Appendix I for the full list of formats, and examples of each. File Block Size – This value controls the size of the blocks which are allocated for file usage①. Choices are: 256 512 1K 2K 4K
Menu 4: Bar Code Menu Parameters
The following is a description of those parameters accessed by pressing <ENTER> when the 4–Bar Code Menu is on the display. Code 3 of 9 . . . . . . . . . Enabled/Disabled The workstation will auto-discriminate between codes that are enabled. In order for the workstation to even attempt to read a code, it must first be enabled. By default, only Code 3 of 9 is enabled. Code 3 of 9 Check Digits Disabled/Enabled Enables check digit verification of all codes read using Code 3 of 9.
① See the chapter on RAM files in the A-B VBASIC Program Development Manual. 5–8