For the Allen-Bradley 2708
Page 12
Chapter
A–B
1
Introduction Chapter Objectives
Allen-Bradley workstations are designed to be rugged and very reliable when installed using the correct voltage and network cabling. An inexpensive network connector (Catalog No. 2708-NNC) has been designed in order to simplify the network installation. Although the workstations may be securely installed without this connector, it is highly recommended that this connector be used. The time saved and the ease of installation will be significant. Chapters 2 through 4 describe network installation, host communication, and the connection of barcode scanners. Installation of a network includes cabling (both power and network) and configuration of the workstations. In some instances, it may be necessary to consult Chapters 5 through 8 for detailed information on the proper ways to configure the workstations.
Catalog Numbers
The catalog numbers covered by this manual include Attended Workstations 2708-DH5B2L and 2708-DH5B4L.
Accessory Items
Accessory items for the 2708-DH5B2L and -DH5B4L workstations are listed below:
Item DH5 Power Supply, U.S. DH5 Power Supply, Europe
Catalog No. 2708-NP1 2708-NP2
DH5 Network Connector
2708-NNC
Application Generator Software
2708-NAG
Network Manager Software
2708-NNM
Basic Language Development Kit Software Hand-Held Scanner Bar Code Wand Bar Code Wand Bar Code Wand Slot Scanner
2708-NBD 2755-G3, -G6 2755-W1 2755-W2 2755-W5 2755-B1, -B2
Description Accepts 120V AC input power. Accepts 240V AC input power. Communications port connector that may be wired for point-to-point or multidrop applications. Menu-driven development software package for custom application programming. Includes Catalog Nos. 2708–NNM and –NBD. Terminal emulator software utilities package that allows the workstation to be configured for a variety of network configurations. Contains a set of source files that can be used to reduce program development time. Visible laser diode, moving beam, hand-held scanner for bar codes. Visible red light source (high density bar codes). Visible red light source (low density bar codes). Infrared light source (high density bar codes). Slot scanner for bar codes.
1–1
Page 13
Chapter 1 Introduction
Related Publications
The following table lists the publications that are available:
Publication No.
Title
Purpose of Publication
2708-801
Application Generator User’s Manual
Describes how to use Application Generator Software to create custom application programs.
2708-802
Network Manager User’s Manual
Describes how to use the Network Manager Software to configure the workstation for a variety of network configurations.
2708-803
Basic Language Kit User’s Manual
2708-2.3
A-B VBASIC vs. Visual BASICt
Describes how to use the Basic Language Kit source files to reduce program development time. Describes the differences between standard Visual BASICt and the Allen-Bradley VBASIC modified for use with the 2708-DH5B_L workstation.
Safety Information
Throughout this manual we use notes to make you aware of safety considerations.
!
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.
Important: Identifies information that is especially important for successful application and understanding of the product.
1–2
Page 14
Chapter
A–B
2
Installing a Network Chapter Objectives
The physical network is based on a twisted pair cabling technique that follows the Electronic Industrial Association (EIA) RS-485 standard. This standard specifies the electrical characteristics of the balanced voltage digital interface circuit. This electrical standard is similar to the more familiar RS-422 standard. The RS-485 communication drivers are capable of withstanding greater voltage surges and tolerating more installation errors than standard RS-422 communications. The RS-485 network cabling system used by the workstations is a daisy-chain (or multidrop) architecture. Each workstation is directly connected to its neighbor. An example of this multidrop architecture is shown in Figure 2.1. Figure 2.1 RS-485 Multidrop Architecture Network Connector (Catalog No. 2708-NNC)
RS-485
RS-232 or RS-422 From Host
Master
Normal
To Other Workstations
Normal
Normal
Although the workstations in the network may be physically identical, the network role of an individual workstation may be different from its neighbor. The seven possible network configurations are: Normal Master Alternate Concentrator Submaster Alt Submaster Gateway
Standard Workstation Communicates with host computer via COM1 Backup for the Master Connects Submaster to backbone network Connects tributary to Concentrator Backup for Submaster Master/Concentrator
These configurations are described in Chapters 5 through 8 along with workstation set-up instructions. It is necessary to understand the configuration set-up to be able to wire the network properly. The network check out may be entirely accomplished by using the diagnostic tests resident in the workstations. 2–1
Page 15
Chapter 2 Installing a Network
Simple Network
Power Requirements Each workstation must be powered with 28V of AC power. This power is supplied by the power supply (Catalog No. 2708-NP1, -NP2) which is a sealed AC adaptor that is plugged into a wall outlet. The power output cable is plugged into the power connector as shown in Figure 2. A full diagram of all the connectors is shown in Figure 2.2. Figure 2.2 Back Plate of the Workstation
ALLEN-BRADLEY
COM2
MADE IN USA
COM1
BARCODE
485 NET
PWR
In a normal installation, each individual workstation is powered by its own power supply.
The RS-485 Network Bus It is highly important to recognize that the network should be wired to appear as a continuous cable or bus and should not be spliced in a manner that allows the cable to make a 3-way junction. Figure 2.3 shows the right way to wire a network. Figure 2.3 Correct Network Connection Network Connector
Workstation
2–2
Workstation
Workstation
Page 16
Chapter 2 Installing a Network
Simple Network (cont’d)
Figure 2.3 shows the correct method of wiring a network. This figure shows the cable coming into the Network Connector (Catalog No. 2708-NNC) and making connection with the cable coming out of the connector. If the workstations are removed from their respective network connectors, it is easy to determine that a continuous cable or bus has been created. The network is a signal transmission line and cannot be treated the same as a power voltage line. The transmission line operates at considerably higher frequencies and therefore must be properly wired and terminated (resistance loaded). If this network transmission line is not installed properly, as shown in Figure 2.3, then voltage standing wave reflections (VSWR) and various other propagation phenomenon may occur. This could cause workstations to not come on-line, drop off and on-line, or have multiple communication retrys in order to make a signal connection.
!
ATTENTION: It must be emphasized that the network cable be installed as a transmission line and not as a power voltage line.
As discussed in this section, a simple network consists of a single cable to connect up to 32 workstations. This is called a “backbone” network and is diagramed on Figure 2.4. Figure 2.4 Simple Network Configuration Host W M
M - W - W - W - W - W - W - W - W - W Workstation Master Indicates RS-232 Indicates RS-485 backbone
No more than 32 workstations can be connected to the same network cable. If more than 32 workstations are required, refer to the Complex Networks section.
The Network Connector (Catalog No. 2708-NNC) The Network Connector is made up of three elements. These are (1) the plastic shroud or hood, (2) the DB-9 connector, and (3) the four screw terminal block. The terminal block is wired to the back of the DB-9 connector. The black terminal wire is connected to pin 5 of the DB-9 connector and is the network (–) side of the RS-485 network. The red terminal wire is connected to pin 4 of the DB-9 connector and is the network (+) side of the RS-485 network. The blue terminal wire is the workstation’s terminal’s chassis ground, and is connected to pin 8. The last terminal slot is open and is not connected to the DB-9 connector. 2–3
Page 17
Chapter 2 Installing a Network
Simple Network (cont’d)
Figure 2.5 Network Connector (Catalog No. 2708-NNC)
Cabling a Network Using the Network Connector Tools Needed, You will need a 3/32” flatblade screwdriver, and a pair of wire strippers/cutter. Cable Wire The recommended cable is a Belden 8723. This cable has 2 pair of conductors (4 wires) and a common drain wire. Although only one pair of conductors is necessary for the network, it is desirable to have a back-up or secondary pair in the event the primary pair has an open wire or some unforseen malfunction occurs in the primary pair. The primary cable pair consists of a Red and Black conductor which match the color of the Network Connector leads. This primary pair will be used in describing the cable connection. Preparing the Wire Check that the cable is cut off evenly. (There should be no wire hanging beyond the cable insulation.) Remove about 3/4” of the insulation from the end of the cable. Strip about 1/4” of insulation from the end of each wire. Figure 2.6 Cable Connecting Length
1/4”
3/4”
2–4
Page 18
Chapter 2 Installing a Network
Simple Network (cont’d)
Installing the Connector There are two types of connections using the Network Connector. These are a Master connection and a Non-Master connection. These connections are shown on Figure 2.7. The physical network connector is shown on Figure 2.4. An examination of both figures shows that there are four open sockets in which to place three wires; the network plus (+), the network (–), and the shield wires. In the Network Connector, the three wires connecting the terminal block to the pins in the DB-9 connector are color coded. This is consistent with all Network Connectors. It is advised the cable be color-coded to match the Network Connector to avoid confusion. Master Connection The network (–) wire is placed in the connector socket for pin 5 of the network connector. The network (+) wire is placed in the connector socket for pin 4 of the network connector. The shield or drain wire is placed in the connector socket for pin 8 and is the ground connection. The shield wire is placed in the blue connector socket ONLY in a MASTER or SUB-MASTER connection. This will effectively ground the network cable at the MASTER only, and eliminate ground loop current problems. Figure 2.7 Schematic of the RS-485 Network Using the Network Connector Network Connector (Catalog No. 2708-NNC) Master Workstation
Normal Workstation
Normal Workstation
To Other Workstations Shield or Drain Wire
Net (+)
Net (–)
2–5
Page 19
Chapter 2 Installing a Network
Simple Network (cont’d)
NON-MASTER Connection The following connections are NON-MASTER connections: Normal Concentrator Alternate Alternate Master Alternate Sub-Master All Non-Master workstations, with the exception of the last workstation in the network, will have a cable going into and a cable coming out of the network connector. This will cause two wires to be installed in each connector socket. This is shown on Figure 2.8. Figure 2.8 Two Wires in a Connector Socket
Twist the network (–) wires (black) together and place them in the black connector socket and tighten the screw. Next, twist the network (+) wires (red) together and place them in the red connector socket and tighten the screw. The only cable leads left should be the drain or shield wires. Twist these together and place them in the empty socket that has NO wire going to the DB-9 connector. Tighten the screw and then examine all connections to make sure they are secure and that no wires are touching any adjacent connections to cause short circuits. If the cable was cut and stripped according to instructions, it should be straightforward to put the shroud on the network connector and complete the assembly. When possible, it is advantageous to use the cable restraint device in the connector to avoid pulling connections loose or breaking the wire. Remember, cabling problems are the number one cause of problems in a network.
2–6
Page 20
Chapter 2 Installing a Network
Step By Step Installation
It is recommended that at least a simple volt/ohm meter along with assorted screwdrivers be acquired for installation. Figure 2.9 The Completed Network Connector
Making a good cable installation is one of the keys to having a properly working network. Cable installation must always alternate between installation and inspection. The inspector’s job is to play devil’s advocate at each phase. By inspecting in phases, you avoid having to do the entire job over again when problems are found too late. We recommend the following sequence: 1. Obtain tools, select connectors and cable type. Get a sample of the cable so you can identify the colors. 2. Draw a MAP of where each workstation is to be placed in the building or area. Trace a general path that the cable will follow in the physical building. Make multiple copies of this diagram. One good way to do the map is to get blueprints of the building and draw in the cables and workstations. Make sure that you note the WORKSTATION NUMBER which will be in each location, as well as the location of the Host computer. 3. Make color keyed cable drawings showing which color wires go to the pins of the connectors. We recommend you make multiple copies of this drawing, and store one copy with the installation map. 4. Run the cable through the building. Always leave a few extra feet at each workstation location so that there is room with which to work.
2–7