Page 137
Appendix
A–B
G
Network Pin-Out Diagrams for DB9 Connector Figure G. 1 Master Workstation Cabling BLACK RED
NET(–) NET(+)
SHIELD/DRAIN
1
2 6
3 7
4 8
5 9
G–1
Page 138
Appendix G Network Pin-Out Diagrams for DB9 Connector
Figure G. 2 Normal/Concentrator Workstation Cabling Solder together or use wire nuts
SHIELD/DRAIN
SHIELD/DRAIN
BLACK RED
BLACK NET(–) RED NET(+)
1
2 6
3 7
4
5 9
8
Figure G. 3 Normal/Concentrator End Workstation Cabling SHIELD/DRAIN
No Connection
NET(–) BLACK NET(+) RED
1
2 6
3 7
4 8
5 9
The previous network diagrams are for use in installations where the Network Connector (Catalog No. 2708-NNC) is not used. To fully understand the correct network wiring, it is highly recommended that Chapter 2 be carefully read.
G–2
Page 139
Appendix
A–B
H
Error Messages and Prompts Errors, Warnings, and Status Messages may appear on the front panel display (Disp), or may be transmitted through the communications port (Comm), or both. The “Seen @” column indicates where to look. Any prompt with “YES” in the “Call/Send In” column is an indication that the workstation is defective: contact your Allen-Bradley distributor for repair information. Message Text
Error
Alpha display . . . . . . . . No AM Timeout . . . . . . . . . No AO . . . . . . . . . . . . . . . . No Bar Code Speed . . . . . . No Bar Devices . . . . . . . . . No Bar Echo . . . . . . . . . . . . No Bar Header . . . . . . . . . . No Bar Trailer . . . . . . . . . . No Baud Rate Clock . . . . . . No BC Register . . . . . . . . . No <Bank display and cursor> . . . . . . . . . No C25 Length #1 . . . . . . . No C25 Length #2 . . . . . . . No C25 Start/Stop . . . . . . . No Code 3 of 9 Check Dgts No Code 3 of 9 Mode . . . . . No Clock Mode . . . . . . . . . No CO . . . . . . . . . . . . . . . . No Code 2 of 5 . . . . . . . . . . No Code 3 of 5 . . . . . . . . . . No Code I 2 of 5 . . . . . . . . . No Comm Baud Rate . . . . . No Comm CR Poll . . . . . . . No Comm CRLF . . . . . . . . No Comm Echo . . . . . . . . . No Comm Loopback Test . No Comm Parity . . . . . . . . . No Comm Receive Test . . . No Comm Stop Bits . . . . . . No
Origin
Seen @
Call/Send In
. . . Display Test . . . . . . . Factory use . . . . . . . Network . . . . . . . . . . Factory use . . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Debugger . . . . . .
Disp . . . . . . No Both . . . . . . No Comm . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No
. . . Standalone . . . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Network . . . . . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . . . . . Menu Prompt . . .
Disp . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Comm . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No
H–1
Page 140
Appendix H Error Messages and Prompts
Message Text
Error
Origin
Comm Transmit Test . . No . . . Menu Prompt . . . Concentrator . . . . . . . . . No . . . Factory use . . . . Config Bad . . . . . Sometimes System . . . . . . . . Config Code . . . . . . . . . No . . . Menu Prompt . . . Config Error . . . . . . . . . Yes . . . System . . . . . . . . Config Saved With . . . . Yes . . . System . . . . . . . . Configuration Disp . . . . No . . . Menu Prompt . . . Constant Memory . . . . . No . . . System . . . . . . . . Continuous RAM Test . No . . . Menu Prompt . . . Count = . . . . . . . . . . . . . No . . . Sensor Test . . . . CRASH (see RESET) CTC FAILED . . . . . . . Yes . . . Powerup Test . . . Date & Time . . . . . . . . . No . . . Clock Status . . . . Date (yymmdd) . . . . . . . No . . . Menu Prompt . . . Debug Bar Code . . . . . . No . . . Factory use . . . . Debugger . . . . . . . . . . . No . . . Menu Prompt . . . Destructive RAM Test . No . . . Menu Prompt . . . Display Text . . . . . . . . . No . . . Menu Prompt . . . Done . . . . . . . . . . . . . . . No . . . System . . . . . . . . DU . . . . . . . . . . . . . . . . Yes . . . Network . . . . . . . EIA Net State . . . . . . . . No . . . Factory use . . . . Enter to start . . . . . . . . . No . . . Menu Prompt . . . External Sensor Test . . . No . . . Menu Prompt . . . FAIL! bb@aaaa . . . . . . Yes . . . Powerup Test . . . Failed! . . . . . . . . . . . . . . Yes . . . System . . . . . . . . Final Exit . . . . . . . . . . . No . . . Menu Prompt . . . I25 Check Dgts . . . . . . . No . . . Menu Prompt . . . I25 Length #1 . . . . . . . . No . . . Menu Prompt . . . I25 Length #2 . . . . . . . . No . . . Menu Prompt . . . Ignore Checksum . . . . . No . . . Menu Prompt . . . K RAM . . . . . . . . . . . . . No . . . System . . . . . . . . Keyboard Echo . . . . . . . No . . . Menu Prompt . . . Keypad/Barcode Test . . No . . . Menu Prompt . . . Lamp Test . . . . . . . . . . . No . . . Menu Prompt . . . Unit will reboot after test . . . . . . . . . . . No . . . Menu Prompt . . . Unit will run test forever . . . . . . . . . . . . No . . . Menu Prompt . . . Master Timeout . . . . . . No . . . Factory use . . . . Max Net Retries . . . . . . No . . . Factory use . . . . Max Net Scans . . . . . . . No . . . Factory use . . . . H–2
Seen @
Call/Send In
Both . . . . . . No Both . . . . . . No Disp . . . . . . No Both . . . . . . No Disp . . . . . . No Disp . . . . . . No Both . . . . . . No Disp . . . . . . No Both . . . . . . No Disp . . . . . . No Disp . . . . . . YES Disp . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Disp . . . . . . No Comm . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Disp . . . . . . YES Disp . . . . . . YES Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Disp . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No
Page 141
Appendix H Error Messages and Prompts
Message Text
Error
Origin
Memory Error . . . . . . . . Yes . . . System . . . . . . . . Menu Password . . . . . . No . . . Menu Prompt . . . Misaligned RAM! . . . . . Yes . . . Powerup Test . . . MO . . . . . . . . . . . . . . . . No . . . Network . . . . . . . Network Baud . . . . . . . . No . . . Factory use . . . . Network Block Transm No . . . Menu Prompt . . . Network Decode to Com . . . . . . . . . . . . . . No . . . Menu Prompt . . . Network Echo to C (raw) . . . . . . . . . . . . No . . . Menu Prompt . . . Network Terminal Mode . . . . . . . . . . . . . . No . . . Menu Prompt . . . Network Test . . . . . . . . No . . . Menu Prompt . . . NF . . . . . . . . . . . . . . . . . Yes . . . Network . . . . . . . NO ERRORS SINCE POWER . . . . . . . . . . . No . . . Language . . . . . . No RAM Detected . . . . Yes . . . Powerup Test . . . OF . . . . . . . . . . . . . . . . . Yes . . . Network . . . . . . . OFF . . . . . . . . . . . . . . . . No . . . Sensor Test . . . . ON . . . . . . . . . . . . . . . . No . . . Sensor Test . . . . ON . . . . . . . . . . . . . . . . No . . . Network . . . . . . . Operation Mode . . . . . . No . . . Network Test . . . Password? . . . . . . . . . . . No . . . Menu Prompt . . . PIO FAILED . . . . . . . . . Yes . . . Powerup Test . . . Power failed at . . . . . . . No . . . System . . . . . . . . RAM OK . . . . . . . . . . . No . . . Powerup Test . . . RAM Test . . . . . . . . . . . No . . . Powerup test . . . RESET . . . . . . . . . . . . . Yes . . . Operating Sys. . . Reset Powerup . . . . . . . No . . . Menu Prompt . . . Reset Unit to Factory . . No . . . Menu Prompt . . . ROM Checksum Failure Yes . . . System . . . . . . . . RTS + CTR + DSR + DTR . . . . . . . . . . . . . No . . . Comm Tests . . . . Saving... . . . . . . . . . . . . No . . . System . . . . . . . . Serial Number . . . . . . . . No . . . System . . . . . . . . SIO FAILED . . . . . . . . . Yes . . . Powerup Test . . . Slave Timeout . . . . . . . . No . . . Factory use . . . . SO . . . . . . . . . . . . . . . . . No . . . Network . . . . . . . Software Version . . . . . No . . . System . . . . . . . .
Seen @
Call/Send In
Disp . . . . . . No Both . . . . . . No Disp . . . . . . YES Comm . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Comm . . . . . No Disp . . . . . . No Disp . . . . . . YES Comm . . . . . No Disp . . . . . . No Disp . . . . . . No Comm . . . . . No Both . . . . . . No Both . . . . . . No Disp . . . . . . YES Disp . . . . . . No Disp . . . . . . No Disp . . . . . . No Disp . . . . . . YES Both . . . . . . No Both . . . . . . No Disp . . . . . . YES Disp . . . . . . No Disp . . . . . . No Disp . . . . . . No Disp . . . . . . YES Both . . . . . . No Comm . . . . . No Disp . . . . . . No
H–3
Page 142
Appendix H Error Messages and Prompts
Message Text
Error
Origin
(station number etc) . . . No . . . Status line . . . . . T <Then numbers> . . . . No . . . Network Test . . . Testing RAM . . . . . . . . No . . . Powerup Test . . . Terminal Mode . . . . . . . No . . . Factory use . . . . Terminal Name . . . . . . . No . . . Menu Prompt . . . Terminal Number . . . . . No . . . Menu Prompt . . . Terminal State . . . . . . . . No . . . Factory use . . . . Terminal Type . . . . . . . . No . . . Menu Prompt . . . The quick brown fox . . No . . . Comm Tests . . . . Time = . . . . . . . . . . . . . No . . . Sensor Test . . . . Time Display . . . . . . . . No . . . Menu Prompt . . . Time (hhmmss) . . . . . . . No . . . Menu Prompt . . . TIME OF ERROR . . . . No . . . Language . . . . . . Tx Block Size . . . . . . . . No . . . Network Test . . . Tx Wait time . . . . . . . . . No . . . Network Test . . . Use Backspace to Sel . . No . . . Menu Prompt . . . Use Control-Z to exit . . No . . . Menu Prompt . . . Use Delete for prev . . . . No . . . Menu Prompt . . . Use Return for next . . . No . . . Menu Prompt . . . Weird Top of Ram . . . . Yes . . . Powerup Test . . . XO . . . . . . . . . . . . . . . . Yes . . . Network . . . . . . . 1-Main Menu . . . . . . . . No . . . Menu Prompt . . . 2-Comm Port Menu . . . No . . . Menu Prompt . . . 3-System Menu . . . . . . . No . . . Menu Prompt . . . 4-Bar code Menu . . . . . No . . . Menu Prompt . . . 5-Read-Only Menu . . . . No . . . Menu Prompt . . . 6-Diagnostics . . . . . . . . No . . . Menu Prompt . . . 485 Net State . . . . . . . . No . . . Factory use . . . . * . . . . . . . . . . . . . . . . . . No . . . Factory use . . . . ––– Menu Mode . . . . . . No . . . Menu Prompt . . .
Seen @
Call/Send In
Disp . . . . . . No Disp . . . . . . No Disp . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Disp . . . . . . No Both . . . . . . No Both . . . . . . No Disp . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Comm . . . . . No Comm . . . . . No Comm . . . . . No Disp . . . . . . YES Comm . . . . . YES Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Both . . . . . . No Comm . . . . . No
Messages beginning with numbers will be any one of the following: Clock line, see also date & time Diagnostic menu prompts, such as 1-Configuration Display Memory size, see K RAM Memory test fail, see FAIL Status line, see station number Sub-menu selections 1 to 4; (i.e. 1-Main Menu) Version number display, as in Software Version
H–4