Page 81

Test Menu

Chapter 7

The Test menu initiates different types of unit tests and displays test results in the LCD window. The Test menu contains four items. See Figure 7-1. Executing tests will disrupt some of the normal operation. See individual menu items concerning tests before executing. LINE ON 1) LOCAL LOOPBCK

PAYLOAD ON NO LOOPBACK

1) NETWORK TESTS

ATT INBAND LLB ANSI FDL PLB

2) REMOTE LOOPBK

ANSI FDL LLB ANSI FT1 LLB NO LOOPBACK ALL ZEROS

4) TEST

3) TEST PATTERN

QRSS ALL DS0S QRSS TST DS0S ALL ONES NONE

4) PATTERN RESULT 2) RUN SELFTEST

(Displays results)

3) PORT TEST

(OPTION PORT)

(Displays results)

4) CANCEL TESTS

Figure 7-1. Test Menu

61202076L1-1

TSU 600 User Manual

7-1

Page 82

Chapter 7. Test Menu

Menu flow is normally depicted from left to right. Arrows on the lower right of the screen indicate the scrolling direction to view additional menu items. At every level of the menu, pressing Cancel returns the system to the previous menu level. Pressing Cancel repeatedly returns the system to the Main menu.

Network Tests Network tests control the activation of loopbacks and the initiation of data test patterns. Network tests are run on the Network Interface (NI). You can select three different test configurations to determine the type of loopback and the pattern to run. Test results display in the LCD window. Executing Network Tests will disrupt normal data flow unless only TST DS0s are selected for testing. Loopback Tests A number of different loopbacks can be invoked locally from the front panel, by T-Watch PRO commands, or remotely by using special inband codes (AT&T D4 network loop up and loop down codes). Additionally, the loopbacks can be remotely controlled by means of out-ofband commands by the T1 ESF FDL or from T-Watch PRO by a modem connection. See Figure 7-2.

7-2

TSU 600 User Manual

61202076L1-1

Page 83

Chapter 7. Test Menu

Network Interface Loopbacks Network interface loopbacks affect the entire T1 data stream. There are two types of network loopbacks: line loopback and payload loopback. Line loopback loops all of the received data back toward the network. The transmitted data is the identical line code that was received, including any bipolar violations or framing errors. Payload loopback is similar to line loopback, except that the framing is extracted from the received data and then regenerated for the transmitted data. TSU 600 NI CSU Secondary Interface

DS1 Payload Loopback Line Loopback

Figure 7-2. Network Loopback Tests

Local Loopbck There are three available choices for setting the local loopback:

Name

Description

Line On

Activates the line loopback

Payload On

Activates the payload loopback

No Loopback

Deactivates the loopback

Scroll to select a setting and record it by pressing Enter. The unit returns to the previous menu level.

61202076L1-1

TSU 600 User Manual

7-3

Page 84

Chapter 7. Test Menu

Remote Loopbk This activates the same loopbacks as Local Loopback but at the far end. It uses either the inband loopup code as specified by ANSI T1.403 for line loopback (ATT In-Band LLB), or the FDL as specified in ANSI T1.403 for payload and line loopback codes. The following options are available:

Name

Description

ATT In-Band LLB

Activates the line loopback using inband code

ANSI FDL PLB

Initiates the transmission of an FDL payload loopup code toward the far end

ANSI FDL LLB

Initiates the transmission of an FDL line loopup code toward the far end

ANSI FT1 LLB

Initiates the transmission of a FT1 loopback using the inband code described in T1.403.

No Loopback

Deactivates the loopback

Remote Loopback can only be used with Fractional T1 if the ANSI FT1 LLB is selected. After a Remote Loopback option is selected, the TSU 600 verifies that the far end is actually in a loopback by checking for the receipt of a code looped back from the far end. Once the Remote Loopback type is selected, the LCD displays the loopback progress by displaying Looping until loopback is verified.

7-4

TSU 600 User Manual

61202076L1-1

Page 85

Chapter 7. Test Menu

Test Pattern Pattern

Description

All Ones

Sends an all ones pattern to the network

All Zeros

Sends an all zeros pattern to the network

QRSS All DS0s

Generates a QRSS test pattern and inserts the pattern into all DS0s

QRSS TST DS0s

Inserts a QRSS pattern in those DS0s mapped as TST in the currently active map (A or B)

None

Terminates pattern generation

QRSS Pattern The QRSS pattern is commonly used to simulate real data in T1 interfaces. This pattern can be assigned to appear in all DS0s or only in TST DS0s. When QRSS is set in all DS0s and one of the network loopbacks previously described is activated at the far end, a total end-to-end integrity check can be run without the need for any external test equipment. When QRSS is assigned to TST DS0s, an integrity check of the link can be run along with normal data flow. The TST DS0s are user assigned as part of the DS0 Map. This sets the pattern for the test and initiates the transmission of the pattern. The test is terminated by selecting None. The following patterns are available:

QRSS always runs at 64K/DS0. Example: 1. Use the up and down key to select QRSS ALL DS0s. 2. Press Enter to record the selection. The TSU 600 starts to generate a QRSS test pattern and inserts the pattern into all DS0s. 3. Select None to end the test.

61202076L1-1

TSU 600 User Manual

7-5

Page 86

Chapter 7. Test Menu

Pattern Result Displays the results of the test currently active. Leaving and returning to this menu item does not interrupt the test. Pressing 2 injects errors into the test pattern. These errors are detected by the device performing the pattern check. Pattern

Description

ES

The number of seconds with at least 1 bit error

BES

The number of seconds with more than 1 bit error and less than 320

SES

The number of seconds with more than 320 bit errors

SYNC

Indicates if pattern sync is (yes) or is not (no) valid. An asterisk (*) indicates if pattern sync has been lost since the start of testing

Clear results by pressing Shift 9. The results are accumulated until the test pattern is set to None or Cleared. Using TST DS0s for testing can be very useful, particularly in Fractional T1 applications. You can run an end-to-end test on the Fractional DS0s by:

1

Setting for Map B the TST in the same DS0 as used by Map A to receive data from an Nx56/64 port, and

2

Looping the far end using a V.54 loopback code on the Nx56/64 port. In addition, a single DS0 can be used for continuous testing while other DS0s are passing normal data.

This will also provide an end-to-end check on the entire link. Set each end to send QRSS in TST DS0s (using 1 DS0) and occasionally view the results on the Pattern Result Menu selection.

7-6

TSU 600 User Manual

61202076L1-1

Page 87

Chapter 7. Test Menu

Run Self-Test The self-test checks the integrity of the internal operation of the electronic components by performing memory tests and by sending and verifying data test patterns through all internal interfaces. Although actual user data cannot be passed during these tests, the self-test can be run with the network and DTE interfaces in place and will not disturb any external interface. The memory portion of the self-test automatically executes upon powerup. A full self-test can be commanded from a front panel menu or from T-Watch PRO. In addition to the specified self-tests, background tests are run on various parts of the internal electronics. These run during normal operation to confirm continued correct functioning. This menu selection is used to execute a full internal self-test. The results of the self-tests are displayed in the LCD. Upon invoking the command, the LCD displays System Self-Test and the Test LEDs are illuminated. Test failures are displayed in the LCD window. The self-test consists of the following tests: Board level tests Each of the TSU 600 boards contain an on- board processor which executes a series of tests checking the circuitry on the board. • RAM tests; EPROM checksum • DS0 map tests • On-board data path; sending a known test pattern through an onboard loop Unit level tests • Front panel LED verification • Phase Lock Loop verify • Board-to-board interface test A test pattern is sent from the controller through a loopback on all other boards and is checked on the controller. This verifies the data path, clocks, and control signals. If a failure is detected, note the failure number and contact ADTRAN Technical Support. The execution of self-test will disrupt normal data flow and prevent remote communication until the self-test is completed. 61202076L1-1

TSU 600 User Manual

7-7

Page 88

Chapter 7. Test Menu

Port Tests The Port Tests menu is used to activate testing of specific data ports. It controls the activation of loopbacks and the initiation of data test patterns. Test results are displayed in the LCD window. The execution of Port Tests will disrupt normal data flow in the port being tested.

Cancel Tests Use this menu selection to deactivate all active tests, including tests on option modules.

7-8

TSU 600 User Manual

61202076L1-1

Page 89

Telnet/Terminal Menus

Chapter 8

MAIN MENU The Telnet/Terminal Main Menu is the first menu displayed after the telnet/terminal session is established. See Figure 8-1. The default telnet/ terminal password is ADTRAN.

Only one telnet/terminal session may be active at a time.

ADTRAN - TSU 600 Password: XXXXXXXX Main Menu 1) Status 2) Config 3) Util 4) Test 5) Remote Menu Access 6) Management Config 7) Flash Download 8) Quit Session

Figure 8-1. Telnet/Terminal Main Menu

61202076L1-1

TSU 600 User Manual

8-1

Page 90

Chapter 8. Telnet/Terminal Menus

Status, Config, Util, and Test Menu Options These menu items can access the same modified menus that you can access through the front panel. For detailed information on the available menu options, refer to the following sections: • Status Menu in Chapter 4. • Configuration Menu in Chapter 5. • Utility Menu in Chapter 6. • Test Menu in Chapter 7. DS0 Maps Configuration Menu The Telnet/Terminal version of the DS0 maps configuration menu takes advantage of the 24-line VT 100 display. Upon entering this menu, the current Temp Map displays followed by nine selections that you can use for configuring and reviewing map information. TEMP MAP DS0 # 1 2 3 4 5 6 7 8 9 10 11 12

PORT IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE

DS0 # 13 14 15 16 17 18 19 20 21 22 23 24

PORT IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE

1) COPY MAP A TO TEMP MAP 2) COPY MAP B TO TEMP MAP 3) CREATE TEMP MAP 4) REVIEW MAP A 5) REVIEW MAP B 6) REVIEW TEMP MAP 7) EDIT TEMP MAP 8) APPLY TEMP MAP TO MAP A 9) APPLY TEMP MAP TO MAP B

Figure 8-2. DS0 Temp Map

• Use the up and down arrows or number keys to move the cursor from one selection to another. • Use the Enter key to perform the action displayed in the LCD to the right of the cursor.

8-2

TSU 600 User Manual

61202076L1-1