Page 91
Chapter 8. Telnet/Terminal Menus
Normally, map configuration involves these steps. Step
Action
1
Initializes the Temp Map to one of three configurations (current Map A, current Map B, or all IDLEs). This step is optional.
2
Edits the Temp Map so that it reflects the desired map configuration.
3
Replaces the current DS0 map A or B configuration with the Temp Map configuration.
Initializing the Temp Map Upon entering the DS0 maps configuration menu, the Temp Map reflects its last configured state. You can then use the following selections.
Use selections... To initialize...
61202076L1-1
1, 2, 3 the displayed Temp Map to one of three configurations.
1, 2 the Temp Map from its current configuration to one which reflects the currently stored Map A or B configurations, respectively.
3 the Temp Map to an all IDLE state.
TSU 600 User Manual
8-3
Page 92
Chapter 8. Telnet/Terminal Menus
Editing the Temp Map If further changes to the Temp Map are needed, do the following:
Step
Action
Explanation
1
Use selection 7 to enter the Temp Map edit mode.
Upon entering this mode, the cursor location moves to DS0 number one in the DS0 field of the Temp Map. The cursor may be moved from one DS0 to another by using the up and down arrows until the cursor is located at the DS0 number whose assigned port needs to be changed.
2
The up and down arrows are then used Press the Enter key to cause the cursor to move to scroll through the possible port selections. into the Port field.
3
Press the ESC key
This restores the previous port assignment and returns to the DS0 field.
4
Press the Enter key
This saves the current selected port and returns to the DS0 field. Once the cursor is again located in the Temp Map DS0 field, press the ESC key a second time to return to selection 1 below the Temp Map display.
Applying the Temp Map Once the Temp Map reflects the desired configuration, use selections 8 or 9 to apply this configuration to Map A or B, respectively. Reviewing Maps Selections 4 through 6 give a summary of the number of ports assigned to Map A, Map B, and the Temp Map, respectively.
8-4
TSU 600 User Manual
61202076L1-1
Page 93
Chapter 8. Telnet/Terminal Menus
Remote Menu Access Displays telnet menus for a remote device (may be another TSU/TDU or any other ADTRAN product that supports telnet via its EIA-232 chain port). After selecting this option, you may choose to connect to a device entered in the Unit Access Table or enter a Unit ID for a unit not in the Unit Access Table. CTRL + X terminates the session and returns to the TSU 600 Main Menu.
Management Configuration This menu sets management information, such as SNMP community names and trap destination addresses. Unit Access Table This menu edits and creates the Unit Access Table. This table stores the Unit ID, Passcode, and Unit Type for units connected via chain ports or connected remotely to the TSU/TDU (see Figure 8-3 on page 8-6). An entry in the table is only required to support proxy SNMP MIB access or polling. For MIB access, an entry is required only if the unit's passcode is not the same as the Default Unit Passcode, or the unit is a single port TSU Stand-alone.
It is not necessary to have an entry in this table for a remote unit in order to telnet to it or forward SNMP traps from it. In the telnet case, the Remote Menu Access menu is selected from the Main menu and a Unit ID is entered which may or may not be in the Unit Access Table.
Units accessed via T-Watch PRO over TCP/IP use the Unit ID and passcode set by T-Watch PRO running on the PC.
61202076L1-1
TSU 600 User Manual
8-5
Page 94
Chapter 8. Telnet/Terminal Menus __________________Unit Access Table_________________ Unit ID
Passcode
Type
Polled
20
DEFAULT
Standard
No
3
0033
Standard
Yes
6
0095
TSU Stand Alone
No
8
0022
Standard
Yes
PollStatus UP UP
1) Add New Unit 2) Modify Unit 3) Delete Unit 4) Default Unit Passcode
0022
5) OK
Figure 8-3. Unit Access Table
Add New Unit This adds a new device to the table. You must enter a device Unit ID, passcode, unit type, and polled flag. The unit type can be Standard (which supports any TSU/TDU Multiplexer and the ISU 512) or TSU Standalone (a single port TSU with no option card slot). You can select a passcode of 0 to 9999 for each device or DEFAULT, in which the default passcode will be used. See Figure 8-3. Traps are normally sent from the unit in alarm to the TSU 600. For units in the Unit Access Table that are not chained directly to the TSU 600 but are managed over Inband or the FDL, traps are not automatically forwarded. Polling must be enabled on the TSU 600 for these units in order to receive Traps on the NMS. The TSU 600 can be configured to poll selected units for traps by enabling the polled option when adding or modifying a unit entry. Modify Unit Allows Unit ID, passcode, device type, and polled flag to be changed for an existing entry in the table. Delete Unit Deletes an entry in the table.
8-6
TSU 600 User Manual
61202076L1-1
Page 95
Chapter 8. Telnet/Terminal Menus
Default Unit Passcode Sets the default passcode for all devices in the table that have passcodes set to DEFAULT, or for any unit not listed in the table. OK Returns to the Configure Agent menu.
SNMP Read Community SNMP Read Community Name defaults to public. NMSs using this community name have Read access for all supported MIB objects but do not have the ability to change MIB objects. This value must be set to the same value on both the TSU 600 and the NMS (OpenView®, etc.) in order for the NMS to have Read access to MIBs supported by the TSU 600. This value must be a text string of 16 characters or less. SNMP Read/Write Community SNMP NMS using this community name have full read/write access to all supported MIB objects (defaults to private). This setting must be the same value on both the TSU 600 and the NMS in order for the NMS to have read/write access to MIBS supported by the TSU 600. This value must be a text string that is 16 characters or less.
To access other units external to the TSU 600 (proxied units) using an SNMP MIB browser, append a period and the Unit ID of the external device to the Read Only and Read/Write community name used in the MIB Browser, for example, public.4. See Appendix A, Understanding SNMP on page A-1, for more information.
61202076L1-1
TSU 600 User Manual
8-7
Page 96
Chapter 8. Telnet/Terminal Menus
SNMP Trap Community This community name is used for all SNMP traps forwarded by the TSU 600. Traps received from daisy chained units have a period and the Unit ID appended to the trap community name.
SNMP Trap Destination Address Host 1 Trap IP Address
Description This is the first of four entries for SNMP trap destination addresses. The TSU 600 forwards all SNMP traps to the IP address specified in this entry. If the address is set to the default value of 0.0.0.0, no traps are forwarded for this particular value.
Host 2 Trap IP Address
Defaults to 0.0.0.0. Second destination address for SNMP traps.
Host 3 Trap IP Address
Defaults to 0.0.0.0. Third destination address for SNMP traps.
Host 4 Trap IP Address
Defaults to 0.0.0.0. Fourth destination address for SNMP traps.
System Name A text string that can uniquely identify an SNMP-managed node. System Contact A text string containing the name, phone number, etc. of the individual responsible for maintaining an SNMP-managed node. System Location A text string describing the physical location of an SNMP-managed node (for example, SECOND FLOOR PBX ROOM).
8-8
TSU 600 User Manual
61202076L1-1
Page 97
Chapter 8. Telnet/Terminal Menus
Auto. Fail Traps Sent (DISABLED, ENABLED: defaults to DISABLED) When enabled, the TSU 600 issues an SNMP trap when any SNMP request is received with an invalid community name. Can be used for security purposes. Poll Link Status Traps Sent (DISABLED, ENABLED, defaults to DISABLED) When enabled, the TSU 600 sends an SNMP trap whenever a device configured to be polled fails to respond. When the device begins responding to polls, a poll link-up trap is sent. The formats of the traps are defined in the agent MIB. Ping IP Host Allows the user to Ping a specific IP address. Telnet/Terminal Time-out The TSU 600 terminates a telnet or terminal session if no activity is detected for this length of time. Only one telnet or terminal session may be active at one time. This time-out prevents an unattended session from blocking interactive access to the agent. The default value is five minutes. Telnet/Terminal Password This option allows modification of the password required for entry into a telnet or terminal session. The default value is ADTRAN. Exit Returns to the TSU 600 Main menu.
Flash Download The TSU 600 uses flash memory that allows software updates via the chain-in port. This menu selection allows you to perform a flash download manually using XMODEM. T-Flash is also available to automate this process.
Quit Session Terminates the telnet/terminal session. 61202076L1-1
TSU 600 User Manual
8-9
Page 98
Chapter 8. Telnet/Terminal Menus
8-10
TSU 600 User Manual
61202076L1-1
Page 99
Appendix A
Understanding SNMP
As local area network (LAN) environments became standardized over the past ten years, multi-vendor equipment grew with competition. It became necessary to manage the various vendor equipment from a single control console. Thus, the SNMP emerged as the standard for managing commercial TCP/IP networks. The term SNMP broadly refers to the message protocols used to exchange information between the network and the managed devices, as well as to the structure of network management databases.
Basic Components SNMP has three basic components: Network Manager, Agent, and MIB. Network Manager This is a control program that collects, controls, and presents data pertinent to the operation of the network devices. It resides on a network management station. Agent This is a control program that responds to queries and commands from the network manager and returns requested information or invokes configuration changes initiated by the manager. It resides in each network device.
61202076L1-1
TSU 600 User Manual
A-1
Page 100
Appendix A. Understanding SNMP
MIB This is an index to the organized data within a network device. It defines the operating parameters that can be controlled or monitored. When requesting the network manager to retrieve or modify a particular piece of information about a network device, the network manager transmits the request to that network device. The agent in that device interprets the incoming request, performs the requested task, and sends its response to the network manager. The network manager collects all the data from the various network devices and presents it in a consistent form.
Commands Using SNMP Version 1, the network manager can issue three types of commands: GetRequest, GetNextRequest, and SetRequest. Command
Description
GetRequest
This command retrieves a single item or the first in a series from a network device.
GetNextRequest
This command retrieves the next item in a series from a network device.
SetRequest
This command writes information to a network device.
Message The network device issues two types of messages: GetResponse and Trap.
A-2
Command
Description
GetResponse
This message is the response to a network manager GetRequest or GetNextRequest command.
Trap
This is an unsolicited message issued by a network device to report an operational anomaly or an alarm condition to the network manager. These messages are typically encased within informational packets and transported over the LAN or WAN (wide area network).
TSU 600 User Manual
61202076L1-1