For the Adtran TSU-600

Page 101

Appendix A. Understanding SNMP

TSU 600 SNMP ACCESS By default, SNMP MIB Browser access to the TSU 600 IP address with the configured community names, accesses the host. The TSU 600 can also act as an SNMP proxy agent for external units. To access MIB variables on externally chained devices, append a period and the Unit ID of the device to the Read and Read/Write community names. Example: If the Read community name configured in the TSU 600 is public, specifying "public.3" as the community name in the SNMP MIB Browser allows reading SNMP MIB variables from externally chained unit 3. If the external unit's passcode is not the default, an entry must be added to the Unit Access Table for SNMP MIB access. See Figure 8-3 on page 86 for a description of this operation. However, SNMP traps for the unit can be forwarded without the entry.

SNMP Trap Configuration Traps received by the TSU 600 from external units and the host unit are converted into SNMP traps and forwarded to the configured NMS. The source of the trap is uniquely identified at the NMS by a combination of the IP address of the TSU 600, and the Unit ID of the sending device. The Unit ID is present in the trap packet appended to the end of the trap community packet name, for example public.4. It is also included as an Octet String variable (adProdPhysAddress) in the trap packet as defined in the individual product MIBs. The latest versions of the product MIBs by default display the appended trap community name in their descriptions. Typical steps required for Management Station trap configuration are loading the device specific MIBs and loading or creating device specific Trap Definition Files. The current product MIBs contain keywords embedded in comments that can be used by some network management platforms to automatically generate Trap Definitions. Otherwise, the descriptions may be used as a template for Trap Definitions. If individual option card port identification and slot identification are required, they are present in the four byte adProdPhysAddress field of the trap packet. The first two bytes are the Unit ID of the base controller (least significant byte first). The next two bytes are port and slot number. This field is the second object identifier in all traps sent from TSU/TDU products.

61202076L1-1

TSU 600 User Manual

A-3

Page 102

Appendix A. Understanding SNMP

For traps from the ISU 512, the Unit ID is the first object identifier. See the product MIBs for more information. Definitions for Poll Link Up/Down traps are included in the TSU 600 MIB file: 600e.MIB. The TSU 600 and TSU 600e share the same MIB.

SNMP MIB Browser Configuration The steps required to configure Network Manager MIB variable access through the TSU 600 are as follows: 1. Load the desired product MIBs on the network management station. If, for example, the administrator is managing TSU 600 and ISU 512 devices, load TSU 600e.MIB, ISU512.MIB, and RFC1406.MIB. 2. Create device entries in the NMS database for all units that are to be managed through the TSU 600. The host unit should be configured as the Proxy agent for the external units. The IP address or host name used for the proxy designation is that of the TSU 600. 3. Set community names in the device’s entries for external units to the TSU 600 community name with the device Unit ID appended as defined in the previous section, TSU 600 SNMP ACCESS on page A-3. 4. Set the device timeout for all device entries in the NMS device database to five seconds, including the host unit.

SNMP MIB Files The TSU 600 supports several standard MIBs including MIB-II (RFC1213), the DS1 T1/E1 MIB (RFC-1406), and the Ethernet MIB (RFC1643; 600e only). It also supports several ADTRAN enterprise specific MIBs including the ADTRAN Product MIB (ADTRAN.MIB), the ADTRAN DS1 extensions MIB (ADS1.MIB), and all TSU/TDU Enterprise MIBs, such as 600e.MIB. The standard MIB files are usually included with most SNMP network management software. The latest versions of the ADTRAN enterprise-specific MIBs are available in the following locations:

A-4

•

ADTRAN anonymous ftp site (ftp.adtran.com),

•

By dial-up from the BBS (256-963-8169).

•

ADTRAN web site at http://www.adtran.com.

TSU 600 User Manual

61202076L1-1

Page 103

Appendix B

Understanding TR-08

The TSU 600 chassis functions as a Remote Terminal in Digital Loop Carrier and as Integrated Digital Loop Carrier Systems as described in TR-TSY 000008. The TSU 600 supports SLC96 framing, Mode I operation, ORB-13 and ORB-16 alarm formats, alarm reporting, and user-definable BPV threshold detection rate. A basic familiarity with DLC systems, IDLC systems, and TR-TSY000008 is assumed, but the following information will be useful: •

All received TR-TSY-000008 specific alarms are reported locally within the history feature of the TSU 600.

•

When the DISABLE ALARMS option is selected, no alarms will be sent on the DLF, but received alarms will be reported locally in the history.

•

Other alarms normally reported by the TSU 600 will also be placed in history.

•

Each TSU 600 needs to be configured as the A SHELF, as it is provisioned as a separate entity.

•

All alarms will refer to A SHELF when received from TSU 600.

61202076L1-1

TSU 600 User Manual

B-1

Page 104

Appendix B. Understanding TR-08

The following table explains what conditions trigger alarms and how alarms are processed when received by the TSU 600.

Table B-1. Alarm Conditions

Name

Explanation

FELP

When the TSU 600 receives a FELP alarm, it will loop the incoming data directly to the outgoing data. LINE ON is placed in history. The alarms and loopback are cleared when FELP is no longer received.

Loss of Data

The TSU 600 will send MINOR ALARM and the A SHELF ALARM for 2.5s when it quits receiving the data link on the T-Span. It will also report TR-08 DL Down in the history. After 2.5s, MAJOR ALARM, A SHELF ALARM are sent across the Data Link.

OOF

The TSU will send MINOR ALARM and A SHELF ALARM upon receiving an out-of-frame condition. TR-08 DL Down and RED ALARM are declared in history for severe framing errors. After 2.5s, MAJOR ALARM, A SHELF ALARM are sent across the Data Link.

Loss of Signal The TSU 600 will send MINOR ALARM and the A SHELF ALARM for 2.5s when it quits receiving a signal from the far end. It will also report TR-08 DL Down and LOS in the history. After 2.5s, MAJOR ALARM, A SHELF ALARM are sent across the Data Link, and RED ALARM is declared in history.

B-2

BPVs

BPVs that are received at a rate greater than the threshold set under TR-08 options, will cause MINOR ALARM and A SHELF ALARM to be sent on the DL. If the BPVs remain above the threshold for 2.5s, the TSU 600 will send MAJOR ALARM and on the DL. No events are placed in history.

Protection Line Switch

The TSU will not respond to this alarm.

TSU 600 User Manual

61202076L1-1

Page 105

Appendix B. Understanding TR-08

TR-08 DS0 Conversion Table The following table contains the mapping conversions needed to map voice ports to the TR-08 network. Table B-2. TR-08 DS0 Conversion Table

61202076L1-1

DS0

TR-08 Channel Number

Port

1

1

1.1

3

2

1.2

5

3

1.3

7

4

1.4

9

5

2.1

11

6

2.2

13

7

2.3

15

8

2.4

17

9

3.1

19

10

3.2

21

11

3.3

23

12

3.4

2

13

4.1

4

14

4.2

6

15

4.3

8

16

4.4

10

17

5.1

12

18

5.2

14

19

5.3

16

20

5.4

18

21

6.1

20

22

6.2

22

23

6.3

24

24

6.4

TSU 600 User Manual

B-3

Page 106

Appendix B. Understanding TR-08

B-4

TSU 600 User Manual

61202076L1-1

Page 107

Network Pinouts

Appendix C

WIRING Network On the rear panel of the TSU 600 is an 8-position modular jack labeled NETWORK. This connector is used for connecting to the network. See Table C-1, Network Pinouts for the pinout for the network connector. Network Connections The network connections are as follows: Connector Type

(USOC) RJ-48C

Part Number

AMP# 555164-2

Table C-1. Network Pinouts

Pin

Name

Description

1

R1 RXDATA-RING

Receive data from the network

2

T1 RXDATA-TIP

Receive data from the network

3

UNUSED

4

R1 TXDATA-RING

Send data toward the network

5

T TXDATA-TIP

Send data toward the network

6,7,8

61202076L1-1

UNUSED

TSU 600 User Manual

C-1

Page 108

Appendix C. Network Pinouts

Control In/Chain In This is used as an EIA-232 port for connection to a computer or modem (Control-in) or to another TSU 600 or TSU 100 (chain-in). See Table C-2, Control In/Chain In Pinout for the pinout for the control-in/chain-in connector. Chain-in Connections The chain-in connections are as follows: Connector Type

RJ-48

Part Number

AMP# 555164-2

Table C-2. Control In/Chain In Pinout

Pin

C-2

Name

Description

1

GND

Ground-connected to unit chassis

2

RTS

Request to send-flow control

3

RXDATA

Data received by the TSU 600

4

UNUSED

5

TXDATA

6,7

UNUSED

8

CTS

Data transmitted by the TSU 600

Clear to send -- flow control

TSU 600 User Manual

61202076L1-1

Page 109

Appendix C. Network Pinouts

Chain-Out This is used to connect to another TSU 600 chain-in connector. See Table C-3, Chain-Out Pinout for the pinout for the chain-out connector. Chain-out Connections The chain-out connections are: Connector Type

RJ-48

Part Number

AMP# 555164-2

Table C-3. Chain-Out Pinout

Pin

Name

1

GND

2

UNUSED

3

TX DATA

4

UNUSED

5

RX DATA

Description Ground-connected to unit chassis. Connected to GND of next unit (pin 10).

Data transmitted to chained units by the TSU 600. Connect to RX DATA of the next unit (chainin pin 3).

Data received from chained units by the TSU 600. Connect to TX DATA of the next unit (chainin pin 5).

6,7,8 UNUSED

61202076L1-1

TSU 600 User Manual

C-3

Page 110

Appendix C. Network Pinouts

10BaseT (600e only) 10BaseT is used to connect the TSU 600e to the Local Area Network. See Table C-4. 10BaseT Connections The required wiring connections are: Connector Type

(USOC) RJ-45

Part Number

AMP# 555164-1

Table C-4. 10BaseT Ethernet

C-4

Pin

To NIC

1

TX1

2

TX2

3

RX1

6

RX2

TSU 600 User Manual

61202076L1-1