Page 111

Appendix D

System Messages

This appendix lists and defines the alarm and status messages that appear on the TSU 600 screen.

Alarm Messages: Network Interface (NI) Message Red Alarm

Description NI unable to frame align with incoming signal

Yellow Alarm Remote alarm indication (RAI) being received from far end Blue Alarm

Unframed all ones (1s) (AIS) being received at NI

Loss of Signal No signal detected at NI

61202076L1-1

TSU 600 User Manual

D-1

Page 112

Appendix D. System Messages

Status Messages: Network Interface (NI) Message

Description

Payload On

Payload loopback activated

Line On

Loopback off

Loopback Off

All loopbacks deactivated

Factory Restore

Factory setting restored

Power On

Unit powered on

Self-Test

Internal self-test performed

TR-08 DL Down* TR-08 data link is down TR-08 DL Up*

TR-08 data link is up

Minor Alarm*

Loss of sync, carrier loss, BPV threshold exceeded, or data link failure.

Major Alarm*

Conditions for a minor alarm have continued for greater than 2.5 seconds.

*TR-08 alarm messages appearing in the alarm or history log have been received from the far end. If the NI detects one of the above conditions, it will send the appropriate alarm (if enabled) to the far end but no message will appear in the alarm or history log.

D-2

TSU 600 User Manual

61202076L1-1

Page 113

Specifications

Appendix E

ELECTRICAL SPECIFICATIONS T1/FT1 Interface

61202076L1-1

T1 Line Rate

1.544 Mbits/s ± 75bps

Line Code

Bipolar, RZ; AMI or B8ZS

Framing

D4(SF), ESF, or SLC96

FT1 Line Rate

DS0 Channelized (multiple of 64 kbps)

Transmit Timing

Network, DTE, U-BR1TE Secondary NI, Normal (CSU) or Internal

Input Signal

0 to -36 dB (DS-1)

Line Build-out

0, 7.5, 15, 22.5 dB, AUTO

Connector

RJ-45

Test Jacks

Bantam jacks: TX and RX (to Network) and MON

TSU 600 User Manual

E-1

Page 114

Appendix E. Specifications

Compatibility T1 Interface

Pub 62411

ESF Format Interface

TR. 194

ESF Performance Monitoring TR. 54016 and T1.403 FCC Part 15 FCC Part 68 UL 1950

Approvals:

Management Interfaces Chain-In/Chain-Out Ports Interface Devices PC Serial Port, Modem or SLIP connection to router Interface Type

EIA-232

Data Rates

1200, 2400, 4800, 9600, 19200, 38400

Data Format

EIA-232 N81

Protocols

TWATCH/ADLP, ATEL/ADLP, SLIP, TCP/IP

Connector

RJ-45

Option Slot Interface Slots 1-6 Interface

ADTRAN proprietary, accepts standard TSU Option Modules.

Chassis Specification

E-2

Height

Less than 5.25-inch (will fit in a 3U rack mount opening)

Width

Will fit within a 19-inch rack

TSU 600 User Manual

61202076L1-1

Page 115

Appendix E. Specifications

Environmental Specifications Input Power

TSU 600: 90 - 130 VAC 60 HZ TSU 600e: 90 - 120 VAC 50/60 HZ DC powered units: 21 - 26 VDC or 40 - 56 VDC

Fuse

AC powered units: 1A, 250V DC powered units: 5A, 250V

Operating Temperature

0 to 45 degrees C

Max Power 40 W Consumption Max Current

61202076L1-1

AC powered units: 0.7A DC powered units: 3A

TSU 600 User Manual

E-3

Page 116

Appendix E. Specifications

E-4

TSU 600 User Manual

61202076L1-1

Page 117

Index Numerics

ANSI FDL PLB, remote loopback 7-

10BaseT Connections C-4 10BaseT Interface 2-10 10BaseT, interface with SNMP 3-12

ANSI FT1 LLB, remote loopback 7-

4

A Access, unit menu 5-9 Active Alarms 4-4 Add New Unit to unit access table, how to 8-6 ADTRAN PC Management Program, T-Watch PRO 3-11 ADTRAN PC Program, T-Watch PRO 3-11 ADTRAN Web page 3-12 Agent, SNMP component A-1 AIS Alarm, (Blue Alarm) network interface alarm message D-1 Alarm (red), LED description 3-2 Alarm (red), module status LED 3-

3 Alarm Conditions, TR-08 B-2 Alarm Format, TR-08 5-3 Alarm Messages Network Interface (NI) D-1 Alarm Messages, Network Interface D-1 Alarm Report, TR-08 5-3 Alarm, operation key 3-5 ANSI FDL LLB, remote loopback 7-

4 61202076L1-1

4 APPLY TEMP > A, DS0 map menu item 5-13 Applying the Temp Map, how to 8-

4 AS, available sec., NI errors 4-2 ATT In-Band LLB, remote loopback

7-4 Auto. Fail Traps Sent, SNMP 8-9

B Backup Power Supply for TSU 600e

2-2 BES, pattern result, test menu 7-6 BIT STUFFING, network menu item 5-3 Blue Alarm, (AIS alarm), network interface alarm message D-1 Board level tests 2-12 Board level tests, run self-test 7-7 BPV Threshold, TR-08 5-3 BPV, TSU 600 T1 error 4-3, 5-3 BPVs, alarm condition TR-08 B-2

C Cancel Tests, test menu 7-8 Cancel, front panel 3-1 Chain In/Chain Out 2-13

TSU 600 User Manual

Index-1

Page 118

Index

Chain Port Output 2-9 Chain-In (PC) 2-13 Chain-in Connections C-2 Chain-out Connections C-3 Chain-Out Pinout C-3 Chassis Specification E-2 Clear alarm history 4-4 Clear Port Alarm 4-5 Clear,operation key 3-5 CMD Mode, utility menu 6-4 Config, front panel menu 3-10 configuration applications, TSU 600

1-3 DSX1 , option module for TSU 600 1-

3 DTE Timing 5-5

E EDIT TEMP, DS0 map menu item 5-

13

5-12

Editing the Data Field, how to 3-7 Editing the Temp Map, how to 8-4 EF, error free sec., NI errors 4-2 Electrical specifications, TSU 600 E-1 ENET Address, utility menu 6-4 ENET Status 4-6 Enter, front panel 3-1 Environmental Specifications E-3 Error (red), LED description 3-2 ES, Errored Sec., NI Errors 7-6 ES, errored sec., NI errors 4-2 Exit Any Menu Field Operation Or Display, how to 3-8

Create Temp, example, how to 5-13 Ctl Port Rate, unit menu 5-9

F

1-5 Configuration Menu Tree 5-1 Control Port Input 2-9 Control Port, unit menu 5-9 COPY A >TEMP, DS0 map menu item

5-12 Copy, operation key 3-5 CRC, TSU 600 T1 error 4-3 CREATE TEMP, DS0 map menu item

D Data Port Identification 3-9 data port identification 3-9 DC Powered TSU 600, about 2-2 Default Router,unit menu 5-10 Delete Unit in unit access table, how to 8-6 Dial Backup, option module for TSU 600 1-3 Display Only Data Fields 3-8 Drop and Insert, Voice and Router Application 1-6 DS0 Map A and DS0 Map B Menu 5-

Factory Restore, network interface status message D-2 features, TSU 600 1-2 FELP, alarm condition TR-08 B-2 FER, TSU 600 T1 error 4-3 Flash Download 8-9 Flash Download, telnet/terminal menu 8-9 Front Panel Menu Structure 3-10 front panel menu tree 3-6 Front Panel, description 3-1 Full Drop and Insert, option module for TSU 600 1-3

12

G

DS0 Maps Configuration Menu 8-2 DSO Map A and DSO Map B 5-12 DSU DP, option module for TSU 600

GetNextRequest, SNMP command

Index-2

A-2 GetRequest, SNMP command A-2

TSU 600 User Manual

61202076L1-1

Page 119

Index

GetResponse, SNMP message A-2 Grounding Instructions 2-4

H

3-11

Home, operation key 3-5 http //www.adtran.com, ADTRAN Web page 3-12

I INBAND LPBCK, network menu item 5-3 Init Modem, unit menu 5-9 Initialization 2-12 Initializing the Temp Map, how to 8-

3 Installing and Replacing the Power Supply, how to 2-3 Internal Timing 5-6 IP Address, unit menu 5-9

L LCD Menu Options 3-10 LCD Window, front panel 3-1 Line On, network interface status message D-2 Line On, setting local loopback 7-3 Local Loopbck, test menu 7-3 Loopback Off, network interface status message D-2 Loopback Tests, test menu 7-2 Loss of Data, alarm condition TR-08

B-2 Loss of Signal, alarm condition TR-08

B-2 Loss of Signal, network interface alarm message D-1

M Major Alarm, network interface status 61202076L1-1 message D-2 Management Configuration 8-5 Management software - T-Watch PRO Map Exchange Menu 5-11 MAP In Use A(B) Menu 5-11 MIB, SNMP component A-2 Minor Alarm, network interface status message D-2 Modify Unit to unit access table, how to 8-6 Module Status LEDs 3-5

N Network 7-2 Network (NI) Menu Item, configuration menu 5-2 Network (NI), configuration menu 5-

2 network connections, pinouts C-1 Network Interface Errors 4-3 Network Interface Loopbacks, test menu 7-3 network interface, (NI) port 2-9 Network Manager, SNMP component

A-1 Network Performance Reports 4-2 Network Test Interface 2-9 Network Tests, test menu 7-2 Network, pinouts C-1 NI errors, AS (available sec.) 4-2 NI errors, EF (error free sec.) 4-2 NI errors, ES (errored sec.) 4-2 NI Errors, ES, Errored Sec 7-6 NI errors, SES, Severly Errored Seconds 7-6 NI errors, SES, severly errored seconds 4-2 NI errors, UAS (unavailable errored sec.) 4-2 No Loopback, remote loopback 7-4

TSU 600 User Manual

Index-3

Page 120

Index

No Loopback, setting local loopback

7-3 No Unit ID Desired, utility menu, what to do 6-4 Normal (CSU) Timing 5-8 Normal Power-Up Procedure 2-14 Numeric Keypad, front panel 3-1 Nx56 1-3 Nx56/64 module, router interface 1-6 Nx56/64 Serial Interface, option module for TSU 600 1-3 NxIQ, option module for TSU 600 1-3

O message D-2 power-up procedure 2-14 Power-up Testing 2-11 Product Description, TSU 600 1-1 Product Overview, TSU 600 1-1 Protection Line Switch, alarm condition TR-08 B-2 Proxy Traps, unit menu 5-10 PS Status, power supply 4-6

Q QRSS Pattern, test menu 7-5 Quit Session, telnet/terminal session

8-9

OCU DP, option module for TSU 600

R

1-3 OFF, map exchange menu 5-11 OK (green), LED description 3-2 OK (green), module status LED 3-3 OOF, alarm condition TR-08 B-2 operation keys 3-5 Option Module Architecture 1-4 Option Module Architecture, for TSU 600 1-4 Option Slot Arrangement, for TSU 600

2-10

Rear Panel Layout, of TSU 600 2-5 Receipt Inspection, for TSU unit 2-1 Red Alarm, network interface alarm message D-1 Remote Loopbk 7-4 Remote Menu Access 8-5 Remote Port 4-5 REVIEW MAP A(B), DS0 map menu item 5-13 REVIEW TEMP, DS0 map menu item

5-13

P

3

Reviewing Maps, how to 8-4 router interface with Nx56/64 module 1-6 Router, PBX, Video Conferencing Application 1-5 Run Self-Test, test menu 7-7

Ping IP Host, SNMP 8-9 Poll Link Status Traps Sent, SNMP 8-

S

Pattern Result, test menu 7-6 Payload On, network interface status message D-2 Payload On, setting local loopback 7-

9 port configuration 5-15 Port Status 4-5 Port Tests, test menu 7-8 Port Utility, utility menu 6-4 Power Connection for TSU 600 2-2 Power On, network interface status Index-4

Secondary Timing 5-7 Selecting and Activating a Menu Item, how to 3-6 Self-Test, network interface status message D-2 SES, Severly Errored Seconds, NI

TSU 600 User Manual

61202076L1-1