Page 71

Chapter 5. Configuration Menu

Map Exchange (Map Xchng) Menu The Map Exchange menu enables and sets the automatic time-of- day map switch. The unit provides selection of the hour, minute, and seconds for the map switching to take place. The menu items are:

OFF

Indicates the map in use does not change (disabled).

Off disables the Automatic Map Change feature. Press Enter to activate the selection. AUTO

Indicates that the map in use will change at a userselected time of day.

AUTO enables the Automatic Map Change feature. Press Enter to activate the selection When Auto is selected, the unit displays the screens to set times for switching. After editing Map A, press Enter to record the Map A settings and activate the selection fields for Map B. Use the same operation to edit switching time for Map B. When ESF is used with an FDL channel between units, the units automatically coordinate the automatic map switch by sending a map switch command from end-to-end over the FDL. Only one end needs to be set to Auto for this to work.

MAP In Use: A(B) Menu This menu item controls the DS0 map the TSU 600 uses and displays the map in current use.

61202076L1-1

TSU 600 User Manual

5-11

Page 72

Chapter 5. Configuration Menu

DS0 Map A and DS0 Map B Menu The DS0 maps designate which DS0s are assigned to which port. See Figure 5-7. There are three maps: DS0 Map A, DS0 Map B, and the Temporary (Temp) map.

TEMP

DS0 A

DS0 B

Figure 5-7. DS0 Map Designations

DS0 A and DS0 B are the current maps the TSU 600 uses. The Temp Map generates a map before putting it into use. You can copy DS0 A to DS0 B by copying the DS0 A map into the Temp map. Then apply (write) the Temp map into DS0 B. The menu items are:

COPY A >TEMP

Copies the current map (A or B) into a Temp map area. Permits modification without disturbing the existing map. When the modifications are completed, the Temp map is written to current MAP A (B) by selecting Apply.

CREATE TEMP

5-12

Creates a map by defining a port or Idle for all DS0s. When CREATE TEMP is first selected, all DS0s are set to Idle. See Create Temp Example on page 5-13 for more information.

TSU 600 User Manual

61202076L1-1

Page 73

Chapter 5. Configuration Menu

REVIEW MAP A(B)

Permits a quick review of the number of DS0s assigned to each port and the number of unassigned DS0s (Idle or TST) as defined in the currently applied Map A(B).

REVIEW TEMP

This menu item is operated the same for the Temp map as is 3)REVIEW MAP A or Map B.

EDIT TEMP

The map in the Temp file can be edited to whatever configuration is desired. If Map A had been copied into the Temp file, then after editing, the Temp file could be applied to MAP A or MAP B. The menu operation is identical to 2) CREATE TEMP with the exception that the existing port selections display.

APPLY TEMP > A Writes the Temp map into Map A. Pressing Apply is usually the last step in updating a map and is accessed automatically at the end of editing or creating a temporary map. It can be bypassed at this time by selecting another menu choice. Create Temp Example A sample selection follows for Create Temp: DS0: 01 to 24 PORT: IDLE, TST, + option module ports

TST designates which DS0s are used for QRSS testing when activated under the TEST Menu. When not used for testing, the TST designation is identical to IDLE.

61202076L1-1

TSU 600 User Manual

5-13

Page 74

Chapter 5. Configuration Menu

1. With the cursor on CREATE TEMP , press Enter. The unit displays the selection screen with the cursor positioned on the first selection DS0 number. See Figure 5-8. Select DSO Number

Select Port

Figure 5-8. Create Temp Selection Screen

2. Enter the DS0 number by using either the scroll method or numbers. Do not mix the use of the keys. 3. Pressing Enter completes the selection and moves the cursor to PORT, the next field. 4. Scroll to select the port which is dependent on the installed option card. 5. Press Enter to complete the selection and move the cursor back to the DS0 field. With the cursor on the DS0 field, the DS0 number can be incremented or decremented by scrolling. If you press Copy, the contents of the last DS0 entered are placed in the new DS0 number. When all entries are complete, Cancel moves the cursor to the last of the submenu choices, 6)APPLY. Either apply the newly created DS0 map or press Cancel to return to the DS0 Map A (B) submenu choices.

Selecting Apply will not disrupt the operation of unmodified ports.

5-14

TSU 600 User Manual

61202076L1-1

Page 75

Chapter 5. Configuration Menu

Port Configuration (Port Config) Port Configuration selects and configures the parameters associated with any data port in the unit. For example, parameters for the DSX-1 (PBX) interface are set through this menu. The items that can be set depend on which option module is installed. The list of option ports will vary with the configuration. The TSU 600 is designed so that any additional ports developed in the future will contain the appropriate menu selections to provide access by use of this menu item. The Config menus for options ports are described in separate sections of the manual supplied with the option card.

61202076L1-1

TSU 600 User Manual

5-15

Page 76

Chapter 5. Configuration Menu

5-16

TSU 600 User Manual

61202076L1-1

Page 77

Utility Menu

Chapter 6

The utility menu tree displays and sets system parameters. See Figure 61. This includes setting the time and date, resetting all parameters to factory values, or re-initiating the unit. This menu also displays the unit software revision and the Unit ID setting. TIME: HH:MM:SS 1) TIME/DATE

DATE: MM/DD/YY

2) FACTORY RESTORE to factory settings)

3) SET PASSCODE

NEW PASSCODE

(Returns all configurations

3) UTIL

VERIFY PASSCODE 4) UNIT ID

5) SOFTWARE REV

(Displays Current Software Revision

6) PORT UTILITY

(OPTION PORTS)

7) ENET ADDRESS (600e only) 8) CMD MODE

Figure 6-1. Utility Menu Tree

61202076L1-1

TSU 600 User Manual

6-1

Page 78

Chapter 6. Utility Menu

Menu flow is normally depicted from left to right. Arrows on the lower right of the screen indicate the scrolling direction to view additional menu items. At every level of the menu, press Cancel to return the system to the previous menu level. Pressing Cancel repeatedly returns the system to the Main menu.

Time/Date This menu option displays or edits the current time and date. The TSU 600 maintains the time and date during power-off conditions. If you want to...

Do this...

Record the entry and move to the next editing position

Press Enter after any numeric change

Move to a different field to edit

Press Enter at the editing position without making any changes, or Use the Up and Down Arrow keys

End the editing process

Press Cancel

Factory Restore This menu item restores the factory default settings for all unit parameters, including configured DS0 maps.

Set Passcode Enter Passcode from Other Menus The Passcode prompt may make an unexpected appearance from other menu operations. This happens only when the unit is operating in the limited access mode, i.e., without an active passcode. The limited access mode may become active even if a passcode was entered, as it does when there is no activity for ten minutes. If the unit is to be remotely accessed using T-Watch PRO, a passcode must be entered. When managing a number of units, the passcode can be the same for all. The unexpected appearance of the Passcode prompt occurs, for example, while operating in a limited access mode and attempting to change the data rate, (2)CONFIG, 2)UNIT, 1)CTL PORT RATE. Use the number keys to enter the correct passcode and press Enter. The unit displays Access Granted.

6-2

TSU 600 User Manual

61202076L1-1

Page 79

Chapter 6. Utility Menu

Pressing any key after entering a passcode causes the unit to return to the previous active menu. In this case it returns to 2)CONFIG, 2)UNIT, 1)CTL PORT RATE to permit changing the data rate. Change/Set a Passcode The passcode can be changed or set at any time or eliminated altogether through the Utility menu item 3)SET PASSCODE. This procedure requires the current passcode (if one is established) for operation. The passcode can only be entered by using numbers. After entering the desired passcode, press Enter. Set a null passcode at the 3)SET PASSCODE menu by pressing Enter without any numbers. This sets a null passcode and grants unlimited access. Automatic Time-out Feature For added security protection, the unit is equipped with an automatic time-out for operation with the password. After ten minutes of inactivity, the unit reverts to limited access operation. To make changes in the configuration, the passcode can be reentered. See Set Passcode on page 6-2 for further information concerning passcode use, and both limited and editing access. If the passcode number is lost, contact ADTRAN Customer Service for assistance. No Passcode Desired At the New Passcode prompt (in the Set Passcode menu), press Enter without any numerical entry. The system nullifies the need to enter a password for subsequent use and proceeds to the Unit ID prompt.

Unit ID This menu is used to access the current Unit ID setting. Viewing is available in limited access mode. Editing or changing the Unit ID requires the use of a password as in editing mode. Unit Identification numbers must be between 2 and 999. If an out-of-range number is entered, the unit assumes the upper limit number of 999.

61202076L1-1

TSU 600 User Manual

6-3

Page 80

Chapter 6. Utility Menu

Setting the Unit Identification In the Unit ID menu (item 4) under the UTIL menu, enter any value between 2 and 999. The number 1 is reserved for the PC. Pressing Enter records the Unit ID number and establishes its availability for operation by remote control. The unit proceeds to the Set Control Port prompt. No Unit ID Desired Without entering any numbers at the Unit ID prompt, press Enter. Pressing Enter with no Unit ID recorded establishes the unit as unable to be operated by remote control.

Software Revision (Software Rev) This menu provides access to the display of the current software revision level loaded into the base unit controller. This information is required when requesting assistance from ADTRAN Customer Service or when updates are needed. Use Cancel to exit.

Port Utility This menu provides access to the display of the current software information for each port installed in the unit. This information is required when requesting assistance from ADTRAN customer service or when updates are needed.

ENET Address (600e only) Displays the Ethernet MAC address for the 10BaseT port.

CMD Mode Reserved for factory use.

6-4

TSU 600 User Manual

61202076L1-1