For the Adtran TSU-600
Page 61
Configuration Menu
Chapter 5
The Configuration menu sets the TSU 600 operational configuration, including all network interface parameters, the allocation of the DS0s, and the port parameters. See Figure 5-1. 1) FORMAT
1) NETWORK (NI)
1) CTL PORT RATE
2) CODE
2) TRAPS
3) YEL ALARM
3) ACCESS
4) XMIT PRM
4) INIT MODEM
5) TIMING MODE
5) CONTROL PORT
6) SET LBO
6) IP ADDRESS
7) INBAND LPBCK
7) SUBNET MASK
8) BIT STUFFING
A) ALARM REPORT
8) DEFAULT ROUTER
9)TR-08 OPTIONS
B) ALARM FORMAT
9) SLIP RATE
C) BPV THRESHOLD
A) SLIP FLOW CTL
2) UNIT
B) PROXY TRAPS
3) MAP XCHNG
OFF AUTO
1) MAP A @: HH:MM
4) MAP IN USE: A(B)
2) MAP B @: HH:MM 1) COPY A>TEMP
2) CONFIG 5)DS0 MAP A
2) CREATE TEMP 3) REVIEW MAP A
6) DS0 MAP B
1) COPY B > TEMP
4) REVIEW TEMP
2) CREATE TEMP
5) EDIT TEMP
3) REVIEW MAP B
6) APPLY TEMP > A
4) REVIEW TEMP 5) EDIT TEMP 6) APPLY TEMP > B 7) PORT CONFIG
(OPTION PORTS)
Figure 5-1. Configuration Menu 61202076L1-1
TSU 600 User Manual
5-1
Page 62
Chapter 5. Configuration Menu
Menu flow is normally depicted from left to right. Arrows on the lower right of the screen indicate the direction of scrolling to view additional menu items. At every level of the menu, pressing Cancel returns the system to the previous menu level. Pressing Cancel repeatedly returns the system to the Main menu.
NETWORK (NI) This menu item accesses the configuration of parameters associated with the network interface in the base unit. There are nine submenu items that include setting the format, the Line Build Out (LBO), and the timing mode. Submenu items do not include setting the parameters which may be necessary for a secondary interface (DSX-1 Passthru, etc.).
Network (NI) Menu Items The menu items and their descriptions follow.
Format
Sets the frame format for the NI. Choices: D4, ESF, SLC96 D4 is equivalent to superframe format (SF).
5-2
Code
Sets the line code for the NI. Choices: AMI, B8ZS.
YEL Alarm
Enables and disables the transmitting of yellow alarms. Choices: ENA, DISA
XMIT PRM
Enables and disables the sending of PRM data on the facility data link (FDL). The PRM data continues to be collected even if XMIT PRM is disabled (possible only with ESF Format). Choices: Off, On.
Timing Mode
Selects the clock source for transmission toward the network from the NI. See TSU 600 Clock Sources on page 5-4 for more information. Choices: Network, DTE (Slot 1), Normal (CSU), U-BR1TE (Slot 1), Internal, and Secondary (SI).
TSU 600 User Manual
61202076L1-1
Page 63
Chapter 5. Configuration Menu
SET LBO
Selects the line build out for the network interface. In AUTO mode, the TSU 600 sets the LBO based on the strength of the receive signal and displays the selected value. Choices: 0.0 dB, 7.5 dB, 15 dB, 22 dB, and Auto
To activate the -36 dB receiver sensitivity, set the LBO to AUTO. This feature is useful in a point-to-point application where no network elements are involved. If a network element such as a Smart Jack is installed on the circuit, the LBO should be set to 0 dB. INBAND LPBCK
Sets unit to accept or reject the network interface loop-up and loop-down codes as defined in ANSI T1.403. Choices: Accept, Reject
BIT STUFFING When enabled, bit stuffing causes the TSU 600 to monitor for ones (1s) density violations and insert a one (1) when needed to maintain ones at 12.5%. Choices: Enable, Disable TR-08
The TR-08 submenu configures the unit for TR-08 applications. The submenu items and their descriptions follow. Alarm Report Enables and disables the transmitting of alarm reports. Choices: SEND ALARMS, DISABLE ALARMS Alarm Format Sets the alarm frame format to 13 frames or 16 frames. Choices: ORB-13, ORB-16 BPV Threshold Sets the threshold for BPVs to trigger an alarm. Choices: 10-4, 10-5, 10-6
61202076L1-1
TSU 600 User Manual
5-3
Page 64
Chapter 5. Configuration Menu
TSU 600 Clock Sources The TSU 600 is operable from various clock sources, permitting it to perform properly in many different applications. The network interface timing mode is set by using the Network (NI) Configuration menu options. The following options are available: • Network Timing • DTE Timing • UBR1TE • Internal Timing • Secondary Timing • Normal (CSU) Timing The selected clock option always designates the clock source for transmission. Clocking necessary for receiving data is always recovered from incoming data. Network Timing The network is the source of timing. The received data clocking is looped back to the network, where it is used to determine the transmission timing. This option is also referred to as loop timed as the transmission clock is derived from the received clock. See Figure 5-2.
NETWORK INTERFACE
1
2
3
4
5
6 SECONDARY INTERFACE
TIMING SOURCE
OPTION SLOTS
Figure 5-2. Network Timed Clock Source
5-4
TSU 600 User Manual
61202076L1-1
Page 65
Chapter 5. Configuration Menu
DTE Timing The DTE is the source of timing. The TSU 600 uses the incoming DTE clock to determine the transmission timing. This is typically used in applications where it is necessary to have the DTE as the primary clock source (such as limited distance line drivers). See Figure 5-3. The DTE source timing is restricted from use when a secondary interface is used at the same time.
Clock NETWORK INTERFACE
1
2
3
4
5
6
OPTION SLOTS
DTE
TIMING SOURCE
Figure 5-3. DTE Timed Clock Source
U-BR1TE (Slot 1) The timing mode selection U-BR1TE (Slot 1) works much like DTE timing except that the clock is derived from the U interface.
61202076L1-1
TSU 600 User Manual
5-5
Page 66
Chapter 5. Configuration Menu
Internal Timing The TSU 600 is the source of timing. The TSU 600 is configured to use its own internal oscillator as the source of timing. Applications include private line driver circuits where one end is set to network and the other to internal. See Figure 5-4.
NETWORK INTERFACE
1
2
3
4
5
6 SECONDARY INTERFACE (Option)
OPTION SLOTS
OSC
TIMING SOURCE
Figure 5-4. Internal Clock Source
5-6
TSU 600 User Manual
61202076L1-1
Page 67
Chapter 5. Configuration Menu
Secondary Timing The secondary interface is the source of timing. The TSU 600 uses the clock derived by the secondary interface for transmission timing. See Figure 5-5.
NETWORK INTERFACE
1
2
3
4
5
6 SECONDARY INTERFACE (Option)
OSC
OPTION SLOTS TIMING SOURCE
PBX or Second Network
Figure 5-5. Secondary Clock Source
61202076L1-1
TSU 600 User Manual
5-7
Page 68
Chapter 5. Configuration Menu
Normal (CSU) Timing The typical timing option arrangement is shown in Figure 5-6. The PBX is looped timed to the TSU 600. The Network Interface (NI) is the actual source of timing. This timing option is the same as that typically used for CSUs. This is the preferred mode for use with a PBX application.
NETWORK INTERFACE
1
2
3
4
5
6 SECONDARY INTERFACE (Option)
TIMING SOURCE OSC
OPTION SLOTS
PBX or Second Network
Figure 5-6. Normal (CSU)
5-8
TSU 600 User Manual
61202076L1-1
Page 69
Chapter 5. Configuration Menu
Unit Menu The Unit menu changes the baud rate of the Chain-In port and the setup of the Chain-Out port. The menu items are:
Ctl Port Rate
Sets the baud rate for communication with the PC or modem. Choices: 1200, 2400, 9600, 19200 and 38400 kbps
Traps
Enables or disables the transmission of trap messages. Choices: Enable, Disable
Access
Sets the method of connection from the TSU 600 to T-Watch PRO/SNMP. Choices: Direct - Used if connected directly to the PC Dial - Used when connection is through a modem. The dial string is entered from T-Watch PRO/SNMP.
Init Modem Allows you to choose an industry standard or a custom initialization string for a modem connected to the control port. Control Port Selects the TCP/IP physical interface. Choices: SLIP using the EIA-232 serial port or 10BaseT Ethernet (600e only).
If this option is set to SLIP, the Chain-In port may not be used as a terminal interface. IP Address
61202076L1-1
Uniquely identifies the TSU 600 on a TCP/IP network. This address is composed of four decimal numbers, each in the range of 0 to 255, separated by periods.
TSU 600 User Manual
5-9
Page 70
Chapter 5. Configuration Menu
Subnet Mask
Defines which part of a destination IP address is the network number. Used along with the TSU 600e IP address to determine which nodes must be reached through the default IP Gateway. This value is set to 0.0.0.0 when the IP interface option is set to SLIP.
Default Router
All IP Packets destined for nodes not on the TSU 600e unit’s local network are not forwarded through this IP address. Normally, this address defines a router connected to the TSU 600e unit’s local network. This value is ignored when the IP interface is set to SLIP.
SLIP Rate
Sets the baud rate for the Chain-In port when used as the SLIP connection for SNMP management. Choices: 1200, 2400, 4800, 9600, 19200, 38400
SLIP Flow CTL
Used to activate flow control on the Chain-In port when used as the SLIP interface. Hardware mode uses RTS and CTS. Choices: None, Hardware
Proxy Traps Enables or disables the transmission of trap messages from units being "proxied" for. Choices: Enable, Disable
5-10
TSU 600 User Manual
61202076L1-1