Page 51

Chapter 3. Operation

Alternate Methods of Control T-Watch PRO (ADTRAN PC Program) T-Watch PRO is the ADTRAN PC control program. It provides complete control over the configuration of the TSU 600 using a graphical interface and displays the same status and performance data as the front panel LCD. This data is displayed in the form of tables and graphs. The T-Watch PRO program has the following capabilities: • Interfaces with a modem which permits dialing into a remote TSU 600 location to configure the unit or read the status or performance of the unit. • Receives traps from any TSU product. • Records and creates display performance data over a 30 day period. • Accesses units via the local area network. T-Watch PRO/LAN Connection To set up the TSU 600 to work with T-Watch PRO over the LAN, follow these steps:

Step

1

Action Set the Unit ID using the Front Panel. See Unit ID on page 6-3 for more information.

2

Set Control Port to SLIP or Normal for 10BaseT (600e only) using the Front Panel.

3

Configure the IP address default gateway, and subnet mask using the Front Panel. The default gateway and subnet masks are not used for SLIP mode.

4

61202076L1-1

Follow the installation instructions for T-Watch PRO to start the program and connect to the unit.

TSU 600 User Manual

3-11

Page 52

Chapter 3. Operation

T-Watch PRO/EIA-232 Connection To set up the TSU 600 to work with T-Watch PRO over a direct EIA-232 connection, the following steps are required:

Step

Action

1

Set the Unit ID and the Passcode using the Front Panel. See Unit ID on page 6-3 and Change/Set a Passcode on page 6-3 for more details.

2

Set the Control Port rate to the same setting as the PC Com port.

3

Connect the PC Com port to the Chain-In port on the TSU 600 using the DB25 to modular adapter and 6-foot modular cable.

4

Follow the installation instructions for T-Watch PRO to start the program and connect to the unit.

SNMP The ADTRAN TSU 600 supports the Simple Network Management Protocol (SNMP) through the chain-in (SLIP) interface or 10BaseT interface (600e only). See Appendix B, Understanding SNMP for detailed information. To use SNMP with the TSU 600, do the following:

Step

Action

1

Set Control Port to SLIP for Chain-In Port or Normal for 10BaseT (600e only).

2

Set the IP address, default gateway, and subnet mask through the front panel. The default gateway and subnet mask are not used in SLIP mode.

3

3-12

Load the appropriate MIB browser into the Network Management Station (available on the ADTRAN webpage at http://www.adtran.com). The MIB browser issues SNMP gets/sets to the TSU 600.

TSU 600 User Manual

61202076L1-1

Page 53

Chapter 3. Operation

Terminal Mode Connection The TSU 600 provides the front panel menus to a VT-100 type terminal. This mode can be used to configure and monitor the unit. Initiate this mode by typing <ctrl> PTT on the terminal once it is connected to the Chain-In port. For detailed information on this method of control, see Telnet Terminal Menus on page 8-1. Telnet Connection You can connect to the TSU 600 via telnet. Before attempting to connect via telnet, first define the IP address, the default gateway, and subnet mask using the front panel.

The dafault gateway and subnet mask are not used in SLIP mode.

When you begin the Telnet session, you will be prompted for a password. The default password is ADTRAN. You can change this password using the Management submenu. See Default Unit Passcode on page 8-7, for details. The telnet session will time-out after a predefined value that is also set in the Management Menu.

Only one telnet session can be active at one time.

61202076L1-1

TSU 600 User Manual

3-13

Page 54

Chapter 3. Operation

3-14

TSU 600 User Manual

61202076L1-1

Page 55

Status Menu

Chapter 4

The Status menu branch allows you to view the status of the TSU 600 operation. See Figure 4-1. %AS %EF 1) NI PERF RPTS

ES

2) NI ERRORS

UAS

SES 1)STATUS 3) ACTIVE ALARMS

(ALARM LIST) END OF LIST

4)VIEW HISTORY

(HISTORY LIST) END OF HISTORY

5) PORT STATUS

OPTION LIST

6) REMOTE PORT 7) CLEAR PORT ALM 8) ENET STATUS 9) PS STATUS

Figure 4-1. Complete Status Menu

61202076L1-1

TSU 600 User Manual

4-1

Page 56

Chapter 4. Status Menu

Menu flow is normally depicted from left to right. Arrows on the lower right of the screen indicate the direction of scrolling to use to view additional menu items. At every level of the menu, pressing Cancel returns the system to the previous menu level. Press Cancel repeatedly to return the system to the main menu.

Network Performance Reports (NI PERF RPTS) The Network Interface Performance Reports display the user copy of the performance data. See Figure 4-2. The TSU 600 maintains this performance data on the network in compliance with ANSI T1.403 and AT&T document TR54016. The data displayed is data accumulated over the last 15 minutes and over the last 24 hours. Use the scroll keys to access the complete display of the following report fields: 15 Minutes

24 Hours

Data Values

%AS

% of available seconds

%EF

% of error free seconds

ES

Number of errored seconds (1 or more errors/second

SES

Number of severely errored seconds (more than 320 errors/second)

UAS

Number of unavailable seconds (10 or more consecutive seconds)

Figure 4-2. Network Interface Performance Report

4-2

TSU 600 User Manual

61202076L1-1

Page 57

Chapter 4. Status Menu

If insufficient time has passed to collect data, NA displays. Continue with standard operating procedures to exit the display. When this menu is active, performance data can be cleared by pressing Clear (Shift 9) on the keypad. Only the user copy of the performance data is cleared. Since only the user’s copy of performance data is cleared by the TSU 600, the data displayed here might be different from the data sent to the network as PRM data.

Network Interface Errors (NI ERRORS) The NI Errors submenu displays the types of errors the Network Interface (NI) detects. A blinking CSU error LED indicates that network errors are detected. The asterisk (*) above an item indicates the type of errors detected. The error types are as follows:

61202076L1-1

CRC

CRC-6 bit errors based on the FDL. This is valid only in ESF mode.

BPV

Bipolar violations.

XS0

Excess zeros.

FER

Framing errors.

TSU 600 User Manual

4-3

Page 58

Chapter 4. Status Menu

Active Alarms This menu item displays a list of current alarms reported by either the base controller or any of the ports. If no alarms are current, the menu item displays End of List. See Figure 4-3. This display includes two lines of text. The top line is the alarm source. The bottom line is the alarm message. A list of alarm messages is found in Appendix C, System Messages, on page C-1. In addition to normal menu operation, you can also access this menu item with the Alarm function (Shift 8) on the keypad. If one or more of the Alarm LEDs are illuminated, an alarm is present. Press Cancel to return to the previous menu item. Alarm Source

Alarm Message

Figure 4-3. Display of Alarm Messages

View History This menu item displays and clears the accumulated status changes of the unit.

View History displays a history of the first 20 status changes in the unit, including the date, time, and type of change. The unit also records for viewing the date and time an alarm became active and inactive, as well as the date and time of test activation and deactivation. To clear the View History display, press Clear (Shift 9) with the View History menu active.

4-4

TSU 600 User Manual

61202076L1-1

Page 59

Chapter 4. Status Menu

Port Status Port Status displays the signals monitored on the data ports. For example, an Nx56/64 interface monitors the RTS, CTS, TD, and RD, along with other signal lines. When a port is selected, the LCD indicates whether the signal is present.

Remote Port Remote Port displays the status of activity on the Chain-In remote port. This is useful for troubleshooting communication sessions, as well as verifying cabling. RX

Characters received at remote port.

ID

Unit ID received at remote port.

CRC Correct CRC received. PC

Correct passcode received.

TX

Characters transmitted from the remote port.

Clear Port Alarm Clears the Link Failed alarms on option modules that have been removed from the TSU 600 chassis.

61202076L1-1

TSU 600 User Manual

4-5

Page 60

Chapter 4. Status Menu

ENET Status (600e only) TX

Indicates that data is being transmitted from the 10BaseT port

RX

Indicates that data is being received by the 10BaseT port

LNK Indicates the current status of the 10BaseT link integrity test. This should always be on when the unit is connected to a functional 10BaseT hub. CPU Active when the CPE is accessing the 10BaseT interface.

PS Status (600e only) Displays the status of Power Supply A (PSA) and Power Supply B (PSB) for AC powered units. Displays DC supply for DC Powered units. Possible status: NOT PRESENT, INACTIVE, OK, DC Supply (DC units only)

4-6

TSU 600 User Manual

61202076L1-1