Page 41

Operation

Chapter 3

FRONT PANEL The TSU 600 front panel both monitors operation and controls the configuration of the unit. The TSU 600 front panel is shown in Figure 3-1 on page 3-4. Descriptions of each part of the front panel follow.

Name

Description

LCD Window

Displays menu items and messages in two lines by 16 characters. It also displays alarm and status information.

Enter

Selects active menu items. To select a menu item, press the number of the item. The menu item flashes, indicating it is activated. Press Enter to select the menu item.

Up and down arrows

Up and down arrows are used to scroll through and activate the submenu items available in the current menu. When the submenu items are scrolled, the flashing cursor indicates the active parameters.

Cancel

Pressing the Cancel key stops the current activity and returns the display to the previous menu. Repeat until the desired menu level is reached. When a submenu item is displayed, press Cancel to exit the current display and return to the previous menu.

Numeric Keypad The numeric keypad contains the numbers 0 through 9 which are used to activate menu items and enter information (such as the IP address).

61202076L1-1

TSU 600 User Manual

3-1

Page 42

Chapter 3. Operation

Name

Description To enter special function keys, press and release Shift before pressing the key representing the desired character. See Operation Keys on page 3-5 for a description of the function keys.

Shift

To activate a special function key rather than a number, press Shift and then the key. If you press the key without using Shift, the numbered item becomes active instead of the special function key.

CSU Status LEDs The CSU status LEDs display the operational condition of the network interface located on the controller board in the unit.

Name

Description

OK (green)

Indicates the operation is in the normal mode and no errors have been detected.

Test (yellow)

Indicates that the network interfaces are operating in a test mode. This includes a self-test or a test loopback. When lighted, this LED also indicates that normal data flow is not occurring on the network interface.

Error (red)

Indicates an error such as a BPV, OOF, or CRC.

Alarm (red)

Indicates an alarm condition has been detected. When the alarm condition is no longer valid, the OK LED activates (turns on). To view an alarm condition, select the active alarm menu item or select Alarm by pressing Shift 8. If the alarm conditions have been corrected, the alarm which caused the activation of the Alarm LED can be viewed under the Unit History menu.

3-2

TSU 600 User Manual

61202076L1-1

Page 43

Chapter 3. Operation

Module Status LEDs The module status LEDs display the operational condition of ports installed in the option slots.

Name

Description

OK (green)

Indicates the operation is in the normal mode and no errors have been detected.

Test (yellow)

Indicates that one of the interfaces is operating in a test mode. This includes a self-test or a test loopback. When lighted, this LED also indicates that normal data flow is not occurring in at least one of the module ports.

Alarm (red)

Indicates an alarm condition has been detected. When the alarm condition is no longer valid, the OK LED activates (turns on). To view an alarm condition, select the active alarm menu item or select Alarm by pressing shift 8. If the alarm conditions have been corrected, the alarm which caused the activation of the Alarm LED can be viewed under the Unit History menu.

System (green)

Indicates the status of the power supplies. If the LED is illuminated green, all installed power supplies are functioning properly. If the LED is illuminated red, one or both power supplies are not functioning normally. This feature is for the AC-powered 600e only. For the TSU 600 and DC- powered 600e, the system LED is always green.

61202076L1-1

TSU 600 User Manual

3-3

Page 44

Chapter 3. Operation

. 4

2

1

5

3

6

8 7

9 10 11 TSU 600

ENTER

1

2

3

4

5 ALARM 8 HOME 0

6 CLEAR 9 SHIFT #

7 COPY CANCEL

SYSTEM

12

CSU

*

OK

TEST

ERROR

13

TEST ALARM

ALARM

15 14

OK

16

1

2

3

4

5

6

17

1. LCD Window

Displays menu items and messages in 2 lines by 16 characters.

2. Cancel

Stops current activity and returns to the previous menu.

3. Enter

Selects active menu item

4. Copy

Copies last data entered into the current DS0.

5. Home

Returns to the main menu.

6. Alarm

Quick access to the active alarm display menus.

7. Clear

Clears data/results fields

8. Shift

Provides access to special function keys

9. Alarm (Module Status)

Active when an alarm condition has been detected.

10. Test (Module Status)

Active when the module is in test mode.

11. OK (Module Status)

Operation is in normal mode with no detected errors.

12. System LED

Indicates status of power supplies (600e only)

13. Up and Down Arrows

Scroll through and activate the submenu items available in the current menu. The flashing cursor indicates the active parameter.

14. OK (CSU Status)

Operation is in normal mode with no detected errors.

15. Test (CSU Status)

Active when the network interface is in test mode.

16. Error (CSU Status)

Indicates errors such as BPV, OOF, and CRC.

17. Alarm (CSU Status)

Active when an alarm condition has been detected on the network interface.

Figure 3-1. TSU 600 Front Panel Layout

3-4

TSU 600 User Manual

61202076L1-1

Page 45

Chapter 3. Operation

Operation Keys Name

Description

Copy

Used in the DS0 mapping menu operations to copy the last data entered into the current DS0. This key operates without pressing the Shift key.

Home

Returns home to the Main Menu from any menu location.

Alarm

Used as quick access to the active alarm display menus. This can be activated while any other menu item is in use. When the Alarm Menu is exited, the unit returns to the location of the same menu that was active when Alarm was selected.

Clear

Used in various menus to clear data/result fields.

General Menu Operation The TSU 600 uses a multilevel menu structure containing both menu items and data fields. All menu operations and data are displayed in the LCD window. The menu items are numbered and can be viewed by scrolling with the up and down arrows.

Name

Description

Data Field

You can edit menu items followed by a colon (:)

Display Only You cannot edit menu fields followed by an Field equal symbol (=). This symbol identifies a field used for value display only Arrows

61202076L1-1

Menus that display small up or down arrows in the lower right corner indicate there are more menu items than are visible on a two-line LCD. Access the additional items with the up or down arrows. You can also access undisplayed menu items by using the appropriate menu number.

TSU 600 User Manual

3-5

Page 46

Chapter 3. Operation

Selecting and Activating a Menu Item

Step

Action

1

Choose a menu item by placing the cursor on the desired menu item by either: 1. pressing the number corresponding to the menu item or, 2. highlighting it with the up and down arrows.

2

To activate the Alarm List option from the Status Menu do the following: 1. Activate the Status Menu using the arrow keys or by pressing 1. The cursor will flash on the number next to the activated selection. 2. Press Enter. 3. Use the arrow keys to view submenu items. 4. Choose an item on the submenu such as ACTIVE ALARMS. 5. Select the submenu with the arrow keys or by pressing 3. 6. Press Enter. 7. View the Alarm List using the arrow keys.

The front panel menu tree is shown below. 1) NI PERF RPTS 2) NI ERRORS

1)STATUS

3) ACTIVE ALARMS

(ALARM LIST)

4)VIEW HISTORY

END OF LIST

5) PORT STATUS 6) REMOTE PORT 7) CLEAR PORT ALM 8) ENET STATUS 9) PS STATUS

Figure 3-2. Example of Basic Front Panel Menu Travel 3-6

TSU 600 User Manual

61202076L1-1

Page 47

Chapter 3. Operation

Editing the Data Field Use the following steps to edit data fields preceded by a colon (:).

Step

Action

Result

1

Position the cursor on the The cursor moves to the data field submenu item number (to the right of the submenu item and press Enter. name).

2

Using the arrows, scroll to The value settings display one-at-ascan the available value time in the data field position. settings.

3

When the desired value is When the value is set, the cursor displayed, press Enter to moves back to the submenu item set that value. position, indicating the operation is complete.

4

Select another submenu field or press Cancel to return to the submenu.

61202076L1-1

Pressing Cancel before pressing Enter voids any data changes. The original data value is restored and the cursor returns to the submenu field.

TSU 600 User Manual

3-7

Page 48

Chapter 3. Operation

Display Only Data Fields Data fields preceded by an equal (=) symbol cannot be edited. See Figure 3-3 and the instructions listed below.

Data Field Display Field

Figure 3-3. Display and Data Fields

Step

Action

1

Press Enter to move the cursor to the data field.

2

Use arrows to select AUTO and press Enter. • The unit automatically sets the Line Build Out. • The display field shows the value actually set. • The equal symbol after LBO in the second line indicates the information that follows is displayed data and cannot be edited.

Exit Any Menu Field Operation Or Display Press Cancel as many times as required to return to the desired menu level or press Home to return to the main menu.

3-8

TSU 600 User Manual

61202076L1-1

Page 49

Chapter 3. Operation

Data Port Identification When configuring the unit, menu selections will include options from data port submenus. Selecting of data ports is necessary because the TSU 600 uses a Slot-Port method to identify which data port the menu item is referencing. If a module containing a PBX DSX-1 option card with an Nx56/64 plug-on interface is installed in option slot 6, it would be designated as: DSX-1 Passthru=6.1 Where slot=6 and port =1. The DSX-1 is located in option slot 6 and is the first port in that slot. Nx56/64=6.2 Where slot=6 and port=2. The Nx is located in Slot 6 and is the second port in that slot.

SLOT 1

SLOT 4

SLOT 2

SLOT 5

SLOT 3

SLOT 6

POWER SUPPLY

Viewed from the rear of the TSU 600, the module slots are arranged as shown in Figure 3-4.

Figure 3-4. Module Slots, TSU 600

61202076L1-1

TSU 600 User Manual

3-9

Page 50

Chapter 3. Operation

Front Panel Menu Structure The TSU 600 uses a multilevel menu structure containing both menu items and data fields. All menu operations and data display in the LCD window. The opening menu is the access point to all other operations. Each Main Menu item has several functions and submenus to identify and access specific parameters. The front panel LCD of the Main Menu contains the following options:

Option Status

Description Displays all relevant information for the network and DTE interfaces. For detailed information on status options, see Chapter 4, Status Menu.

Config Displays and sets the TSU 600 operational config(Configuration) uration, including all network interface parameters, the allocation of the DS0s, and the port parameters. For detailed information on configuration options, see Chapter 5, Configuration Menu.

3-10

Util (Utilities)

Displays and sets system parameters. For detailed information on utility options, see Chapter 6, Utility Menu.

Test

The Test menu initiates different types of unit tests and displays test results in the LCD window. For detailed information on test options, see Chapter 7, Test Menu.

TSU 600 User Manual

61202076L1-1