Page 31

Chapter 2. Installation

IDENTIFICATION OF REAR PANEL LAYOUT Figures 2-1a, Figure 2-1b, Figure 2-1c, and Figure 2-1d show the configuration for the rear panels of the TSU 600, TSU 600 with DC Power, TSU 600e, and TSU 600e with DC power.

1

3

2

CAUTION-RISK OF ELECTRIC SHOCK

CAUTION: MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PERSONEL ONLY

SUPPLEMENTAL EARTH GROUND MUST BE CONNECTED PRIOR TO CONNECTION OF TELECOMMUNICATION WIRING.

IN OUT MON

NETWORK

CONTROL /CHAIN IN

10 BASE T

ALL EMPTY SLOTS MUST BE COVERED WITH BLANK PANELS

OUT

4

MODULE 1

MODULE 4

MODULE 2

MODULE 5

P W R

P W R

MODULE 3

MODULE 6

A

B

I

SEE MANUAL BEFORE REMOVING POWER SUPPLY

(600e ONLY)

O

PORT X.1 NX 56/64 PORT X.1

NX 56/64 PORT X.2

V.35

PORT X.2

DUAL FXS

DUAL FXS PORT X.3

V.35

PORT X.3

1A/250V

PORT X.4

90-130 VAC 60 HZ .7A MAX

IN OUT MON SEC. NI PORT X.1

NX 56/64 PORT X.2

DS-1

CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE

V.35

8 6

5

1

T1 Monitor/Test Jacks

2

T1 Network Connection

3

Control In/Out Connection

4

Power Switch

5

Blank panel covering an unused option slot

6

Example of option modules installed

7

Power Cord

8

1A/250V Fuse

7

Figure 2-1a. TSU 600 Rear Panel

61202076L1-1

TSU 600 User Manual

2-5

Page 32

Chapter 2. Installation

1

CAUTION-RISK OF ELECTRIC SHOCK

CAUTION: MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PERSONEL ONLY

SUPPLEMENTAL EARTH GROUND MUST BE CONNECTED PRIOR TO CONNECTION OF TELECOMMUNICATION WIRING.

IN OUT MON

NETWORK

4

3

2

ALL EMPTY SLOTS MUST BE COVERED WITH BLANK PANELS

CONTROL /CHAIN 10 BASE T

IN

OUT

MODULE 1

MODULE 4

MODULE 2

MODULE 5

P W R

P W R

MODULE 3

MODULE 6

A

B

I

SEE MANUAL BEFORE REMOVING POWER SUPPLY

(600e ONLY)

O

PORT X.1 NX 56/64 PORT X.1

NX 56/64 PORT X.2

V.35

PORT X.2

DUAL FXS

DUAL FXS PORT X.3

V.35

PORT X.3

5A/250V

PORT X.4

24/48 VDC

+ IN OUT MON SEC. NI PORT X.1

NX 56/64 PORT X.2

DS-1

-

CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE.

V.35

8

5

6

1

T1 Monitor/Test Jacks

2

T1 Network Connection

3

Control In/Out Connection

4

Power Switch

5

Blank panel covering an unused option slot

6

Example of option modules installed

7

Power Input Terminals

8

5A/250V Fuse

7

Figure 2-1b. TSU 600 with DC Power Rear Panel

2-6

TSU 600 User Manual

61202076L1-1

Page 33

Chapter 2. Installation

3

2

1

CAUTION-RISK OF ELECTRIC SHOCK

CAUTION: MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PERSONEL ONLY

SUPPLEMENTAL EARTH GROUND MUST BE CONNECTED PRIOR TO CONNECTION OF TELECOMMUNICATION WIRING.

IN OUT MON

NETWORK

ALL EMPTY SLOTS MUST BE COVERED WITH BLANK PANELS

4

CONTROL /CHAIN IN

10 BASE T

OUT

5

MODULE 1

MODULE 4

MODULE 2

MODULE 5

P W R

P W R

MODULE 3

MODULE 6

A

B

SEE MANUAL BEFORE REMOVING POWER SUPPLY

O

PORT X.1 NX 56/64 PORT X.1

NX 56/64 PORT X.2

V.35

SEE MANUAL BEFORE REMOVING POWER SUPPLY

(600e ONLY)

PORT X.2

DUAL FXS

DUAL FXS PORT X.3

V.35

I

O

I

PORT X.3

PORT X.4

90-120 VAC 50/60 HZ. .7A MAX

IN OUT MON SEC. NI PORT X.1

90-120 VAC 50/60 HZ. .7A MAX

NX 56/64 PORT X.2

DS-1

V.35

7

8

6

1

T1 Monitor/Test Jacks

2

T1 Network Connection

3

10BaseT Connection

4

Control In/Out Connection

5

Power Switch

6

Blank panel covering an unused option slot

7

Example of option modules installed

8

Power Supply B (if installed) Figure 2-1c. TSU 600e Rear Panel

61202076L1-1

TSU 600 User Manual

2-7

Page 34

Chapter 2. Installation

1

CAUTION-RISK OF ELECTRIC SHOCK

CAUTION: MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PERSONEL ONLY

SUPPLEMENTAL EARTH GROUND MUST BE CONNECTED PRIOR TO CONNECTION OF TELECOMMUNICATION WIRING.

IN OUT MON

NETWORK

5

3

2

ALL EMPTY SLOTS MUST BE COVERED WITH BLANK PANELS

4

CONTROL /CHAIN IN

10 BASE T

OUT

6

MODULE 1

MODULE 4

MODULE 2

MODULE 5

MODULE 3

MODULE 6

P W R

P W R

A

B

I

SEE MANUAL BEFORE REMOVING POWER SUPPLY

(600e ONLY)

O

PORT X.1 NX 56/64 PORT X.1

NX 56/64 PORT X.2

V.35

DUAL FXS

PORT X.2

DUAL FXS

PORT X.3

V.35

PORT X.3

5A/250V

PORT X.4

24/48 HZ.

+ IN OUT MON SEC. NI PORT X.1

NX 56/64 PORT X.2

DS-1

-

CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE.

V.35

9 8

7

1

T1 Monitor/Test Jacks

2

T1 Network Connection

3

10BaseT Connection

4

Control In/Out Connection

5

Power Switch

6

5A/250V Fuse

7

Blank panel covering an unused option slot

8

Example of option modules installed

9

Power Input Terminals

Figure 2-1d. TSU 600e with DC Power Rear Panel

2-8

TSU 600 User Manual

61202076L1-1

Page 35

Chapter 2. Installation

TSU 600 Interfaces The TSU 600 is equipped with six option slots, management interfaces, and a T1 interface, in the rear panel. See Figure 2-2.

LAN PC or Modem

Control 10BaseT Chain Input (600e only) Output NI

TSU 600

Chain Input

Chain Output

NI TSU 600 Option

Network

Figure 2-2. TSU 600 Interfaces

Network Interface The network interface (NI) port provides the connection to the T1. This port complies with the applicable ANSI and AT&T standards. For more information, see Wiring on page B-1. Network Test Interface The IN and OUT test jacks for the network interface provide intrusive test capability for the incoming T1. By connecting to these jacks with test equipment, the T1 connection will be broken, and the test equipment will terminate the incoming T1. The MON test jack provides a bridged access jack for non-intrusive monitoring of the incoming T1. When connected to this jack, the test equipment should be configured for a bridged termination. Control Port Input The control port input provides an EIA-232 input from a PC or a modem for control of the TSU 600. You can also use it as a chain input from another TSU 600 or TSU 100. For more information, see Wiring on page C1. Chain Port Output The chain port output provides an EIA-232 output to chain control to other TSUs. For more information, see Wiring on page C-1. 61202076L1-1

TSU 600 User Manual

2-9

Page 36

Chapter 2. Installation

10BaseT Interface (600e only) The 10BaseT interface provides the LAN interface for managing the TSU 600e with SNMP or T-watch PRO. For more information, see Wiring on page C-1.

Option Slot Arrangement As viewed from the rear of the TSU 600, the slots are numbered as shown in Figure 2-3. All slots are functionally identical except slots one, two, and six. These slots offer additional functions.

SLOT 4

DTE TIMING

SLOT 2

SLOT 5

DIAL BACKUP

SLOT 3

POWER SUPPLY

SLOT 1

SLOT 6 SECONDARY INTERFACE DSX-1; FULL D&I

Figure 2-3. TSU 600 Slot Designation (Rear View)

2-10

Slot 1

Slot 1 is used as the source of DTE timing when the DTE timing mode is selected or as the source of UBR1TE timing when the UBR1TE timing mode is selected. If DTE timing is desired, the DTE interface port sourcing the timing must be connected to Slot 1. This slot will accept all other interface types except Secondary Network interface option modules, including DSX-1 (PBX), the Full Drop and Insert (D&I) network interface, or the multiport Dial Backup (DBU).

Slot 2

Slot 2 is used for the multiport Dial Backup module if it is installed. This slot accepts all other interface types except Secondary Network interface option modules, including DSX-1 (PBX) and the Full Drop and Insert (D&I) network interface.

TSU 600 User Manual

61202076L1-1

Page 37

Chapter 2. Installation

Slots 3-5

Slots 3-5 will accept any interface type except secondary interface, the interface for DTE timing, or the multiport DBU. If other interfaces have any restriction on their location, this will be specified in the individual option card manual (provided with the option cards).

Slot 6

Slot 6 services any option module type including secondary network interface ports (DSX-1 (PBX) and Full D&I), but not the DTE timing source. If a secondary network interface port is to be used, it must be installed in slot 6.

You can use NxDBU modules in any slot.

Power-up Testing When shipped from the factory, the TSU 600 is set to factory default conditions. At the first application of power, the unit automatically executes a memory self-test. A full self-test can be run from the front panel, and a passcode and unit ID may be set using the UTIL menu. Self-Test Upon a power-up, the LCD displays Memory Test Now Testing and the Test LEDs are illuminated.

When . . .

Then . . .

the self-test is complete with no failures detected the OK LED lights up and the LCD momentarily displays All Tests Passed.

a failure is detected a list of failures is displayed in the LCD window

61202076L1-1

TSU 600 User Manual

2-11

Page 38

Chapter 2. Installation

The full self-test procedure (invoked from the front panel or T-Watch PRO) consists of the following tests: Board level tests Each of the TSU 600 boards contains an on-board processor which executes a series of tests checking the circuitry on the board. • RAM and EPROM tests • Verify on-board circuitry Unit level tests • Front panel LED verification • Board-to-board interface test A test pattern is sent from the controller through a loopback on all other boards and checked on the controller. This verifies the data path, clocks, and control signals for the entire chassis.

Initialization Set User Passcode The TSU 600 is designed to operate with or without the use of a passcode. The default condition is without a passcode.

If the unit is to be remotely accessed using T-Watch PRO, you must enter a passcode. When managing a number of units, the passcode can be the same for all the units.

The passcode should be a number easily remembered. Once entered, the passcode is required to access any operation other than viewing. See Set Passcode on page 6-2. Set Unit Identification The Unit ID sets the unit to respond to remote control (controlled by a device other than the front panel or terminal). If no Unit ID is recorded it is not possible to operate from any remote control device, including the local PC for T-Watch PRO or SNMP. See Unit ID on page 6-3 for details.

2-12

TSU 600 User Manual

61202076L1-1

Page 39

Chapter 2. Installation

Set Control Port The TSU 600 can be configured from the control port when T-Watch PRO, SNMP, or the terminal interface is being used. If the control port is to be used, the control port baud rate must also be selected. Chain-In (PC) The unit can be controlled from an external PC connected directly or via modem to the Chain-In port. When using Chain-In, the selection of the Control Port baud rate from 9600 (factory default), 1200, 2400, or 4800, 19200, or 38400 must be made using the Unit Configuration menu. Unless locked out externally, the front panel can also control the unit. Chain In/Chain Out TSU 600 units and other TSUs can be linked together to form a chain. Figure 2-4 provides an example of a chain-in arrangement with a PC or a modem. The first TSU 600 in the chain receives controlling input from the PC or modem.

PC or Modem

Control Input

Chain Out

TSU 600

Chain In

Chain Out

TSU 600/ TSU 100/TSU

Chain In

Chain Out

TSU 600/ TSU 100/TSU

Figure 2-4. Example of Chain In

Subsequent TSUs in the chain are in a position to intake information from another TSU. This in-taking of information from another TSU in the chain is identified as Chain-In. The baud rate for the chained units must match that of the first unit. Unless locked out externally, the front panel can also control the unit. At this point, the Unit Initialization procedure is concluded. If the unit is to be configured remotely, there are no additional items necessary to complete prior to executing remote configuration. 61202076L1-1

TSU 600 User Manual

2-13

Page 40

Chapter 2. Installation

The Passcode, the Unit ID, and the Control Port settings are stored in a nonvolatile memory. This ensures that they are operable for subsequent power-up sequences.

Normal Power-Up Procedure After the unit has been put into operation with the initial power-up and initialization, subsequent power-up procedure includes only the PowerUp Self-Test followed by the request for a passcode (password) if this option was selected during initialization. Use the number keys to key in the previously recorded passcode and press Enter.

2-14

TSU 600 User Manual

61202076L1-1