For the Adtran TSU-600

Page 21

Introduction

Chapter 1

TSU 600 OVERVIEW This manual covers the use of the following products: • TSU 600 • TSU 600 with DC power • TSU 600e • TSU 600e with DC power Unless otherwise stated, the TSU 600 refers to all four products.

Product Description The TSU 600 is a T1/FT1 multiplexer with six option slots and embedded SNMP management. The TSU 600’s six option slots accept one of many available option modules for voice and data applications. Each module offers up to four ports for a total of 24 possible voice or data ports. The TSU 600 serves as the link between user data sources such as: • local area network (LAN) bridges • routers, • computers, • CAD systems, • teleconferencing equipment, and • PBXs. Through the use of multiple data ports, the TSU 600 can simultaneously connect one or more of these devices to a T1 circuit. The amount of bandwidth allocated to each port is custom-programmable. You can manually allocate bandwidth or set the bandwidth to change automatically at predetermined times to use the available bandwidth most advantageously.

61202076L1-1

TSU 600 User Manual

1-1

Page 22

Chapter 1. Introduction

Changes in the configuration do not disrupt data flow in channels that are not being reconfigured. The unique architecture and the availability of option modules provides a path for growth to accommodate future requirements. The TSU 600 offers a wide variety of network management options. You can manage via SNMP through the 10BaseT (600e only) or chain-in ports. If you are using T-Watch PRO, a Microsoft Windows® program, you can manage the TSU 600 via the same 10BaseT (600e only) or chainin ports. An enhanced VT-100 terminal interface is also provided.

Standard Features in the TSU 600 The standard features of the TSU 600 are listed below: • A single T1 interface • Six slots to house option modules with up to four additional data ports, including voice • Architecture that allows mix of port types to meet the data interface requirements • Easy configuration capabilities using simplistic menus displayed in a liquid crystal display (LCD) window operated by a front panel keypad • SNMP, Telnet, and T-Watch PRO management via SLIP or 10BaseT (600e only) • Ability to proxy for “agentless” units • Enhanced terminal mode • Support for a redundant AC power supply (600e only) • Two programmable configuration maps that define the bandwidth allocation between data ports • Data drop and insert, as well as full drop and insert • Flash memory for software updates • Timing selectable from the network, from the slot 1 data port, internally, or from a secondary interface • QRSS; 511 test patterns using Nx option • Fractional T1 loopbacks as defined in annex B of ANSI T1.403-1995 • Extensive self-testing and monitoring to ensure proper operation

1-2

TSU 600 User Manual

61202076L1-1

Page 23

Chapter 1. Introduction

TSU Option Modules Module Name

Description

DSX1

Short haul T1 interface for operation with a PBX (Terminal Interface).

Full Drop and Insert

Permits the dropping of data and insertion of new data into the same DS0 time slot. This module includes a long haul DS1 interface. It can also be used as a second DS1 interface to provide up to 3 MB aggregate throughput.

Nx56/64 Serial Interface Provides a V.35 serial interface in either single or dual versions. NxIQ

Frame-relay aware device that provides detailed information regarding the health and performance of the frame relay circuit.

Voice Interface

2/4 channel FXS/FX0/E&M.

OCU DP

Interfaces to DDS or 4-wire Switched-56.

DSU DP

Provides two sync or async ports (232 or V.35).

Dial Backup

Allows for backup of data upon network T1 failure.

U-BR1TE

Allows ISDN lines to be extended over a T1 line.

61202076L1-1

TSU 600 User Manual

1-3

Page 24

Chapter 1. Introduction

Option Module Architecture The TSU 600 features a unique architecture that allows the addition of six option modules and plug-on boards, providing an opportunity for growth to accommodate many applications. See Figure 1-1. This unique approach allows you to mix interface types to meet any application.

TSU 600

DSX-1 Module OCU-DP Module

Plug on V.35

V.35 Module

Plug on OCU DP

D&I Module DUAL Voice

Plug on Dual Voice

Figure 1-1. TSU 600 Option Modules

1-4

TSU 600 User Manual

61202076L1-1

Page 25

Chapter 1. Introduction

TSU 600 CONFIGURATION APPLICATIONS The following examples illustrate possible configurations of TSU 600 applications.

Router, PBX, Video Conferencing Application In this application, an Nx54/64 module provides a V.35 interface to a router. The PBX is interfaced to the TSU 600 with the DSX-1 module. An OCU DP module and OCU DP plug-on board provide two switched 56 circuits for video conferencing. The SLIP port or 10BaseT port (600e only) allows SNMP network management over the LAN. See Figure 1-2. PBX

TSU 600

ROUTER

SLIP or 10BaseT (600e only)

VIDEO CONFERENCING

SNMP NETWORK MANAGEMENT WORKSTATION

Figure 1-2. Router, PBX, Video Conferencing Application Set Up

61202076L1-1

TSU 600 User Manual

1-5

Page 26

Chapter 1. Introduction

Drop and Insert, Voice, and Router Application The TSU 600 provides a router interface with an Nx56/64 module. A drop and insert module provides a second T1 interface to a remote TSU. T-WATCH PRO (which runs on a PC) easily manages the network. FXO modules are used to provide PBX extensions to remote sites. See Figure 1-3.

TSU 100 A

ENTER

B

1

OK

TEST

ALARM

COPY *

3

E 5

ALARM 8

7 CANCEL

DSU

C

2

D 4 REMOTE 0

HOME 0

F 6

CLEAR 9

SHIFT #

MODULE OK TEST

ALARM

CSU OK TEST

ERROR

ALARM

ROUTER ROUTER

T-WATCH

PBX

Figure 1-3. Drop and Insert, Voice, and Router Application

Set Up

1-6

TSU 600 User Manual

61202076L1-1

Page 27

Installation

Chapter 2

UNPACK, INSPECT, POWER UP Receipt Inspection Carefully inspect the TSU 600 for shipping damages. If you suspect damage, file a claim immediately with the carrier and then contact ADTRAN Customer Service (see the inside last page of this manual). If possible, keep the original shipping container for use in shipping the TSU 600 back for repair or for verification of damage during shipment.

ADTRAN Shipments Include • The TSU 600 • A line interface cable: an 8-position modular to 8-position modular (15 ft.) • A DB-25 to modular adapter • An 8-position, 6-foot modular cable for the Chain-In port connection • The User Manual • Rackmount Brackets • Rackmount Data Sheet

Customer Provides • Cables for any expansion modules to be used with the TSU 600 • 10BaseT cable for connection to a LAN or router (if you plan to use remote management features). This is for 600e only.

61202076L1-1

TSU 600 User Manual

2-1

Page 28

Chapter 2. Installation

Power Connection The AC- powered TSU 600 is equipped with a captive, 8-foot power cord, terminated by a 3-prong plug which connects to a grounded power receptacle. Power to the TSU 600 must be from a grounded 90-120 VAC, 50/ 60Hz source. DC Powered Units The DC-powered TSU 600 (1202076L1#DC or 1202076L2#DC) is equipped with a terminal strip on the rear of the unit. The power source should be connected to the terminal strip according to the polarity markings on the unit. Example: A -48V source would be connected with the -48V return attached to the (+) terminal and the -48VDC attached to the (-) terminal. Power must be from a DC source in the range of 21 to 26 VDC or in the range of 40 to 56VDC. The protective cover should be reinstalled over the terminal strip once the power source is connected. The DC-powered TSU 600 is to be installed only in restricted areas (dedicated equipment rooms, equipment closets, etc.) in accordance with Articles 110-16 and 110-18 of the National Electric Code, ANSI/NFPA 70. Backup Power Supply (600e only) The TSU 600e has two power supply slots on the right side of the chassis. The base unit is shipped with a single power supply. The TSU 600e is fully operational with only a single power supply, which may be installed on either the left (power supply A) or the right (power supply B). You can install a backup supply in the unused slot. The red System Alarm LED on the front panel will indicate failure of either supply.

2-2

TSU 600 User Manual

61202076L1-1

Page 29

Chapter 2. Installation

Installing and Replacing the Power Supply The following steps show how to install a new supply or replace a failed supply.

Power does not have to be turned off on a working supply to add a new supply or replace a failed one.

Step

1

Action One Power Supply If only one supply is installed in the chassis, remove the blank panel covering the unused power supply slot. Two Power Supplies If two power supplies are installed, the failed supply can be identified by the alarm on the front panel LCD. The alarm message will identify a failure on Power Supply A or Power Supply B. The option slot legend on the rear panel shows the location of each power supply. Turn the power switch to Off on the failed supply and unplug the power cord from the power source.

61202076L1-1

2

Remove the two screws that secure the power supply module to the TSU 600e chassis and remove the failed power supply module.

3

Remove the new power supply from the shipping container. Make sure the power switch is in the Off position.

4

Plug the new supply into the open power supply slot and install the two screws on the power supply module

5

Plug the new power supply cord into a grounded 115 VAC, 50/60 Hz power receptable.

6

Turn the power switch On.

TSU 600 User Manual

2-3

Page 30

Chapter 2. Installation

GROUNDING INSTRUCTIONS The grounding instruction information is from the Underwriters' Laboratory UL 1950, 3rd Edition. An equipment grounding conductor that is not smaller in size than the ungrounded branch-circuit supply conductors is to be installed as part of the circuit that supplies the product or system. • Bare, covered, or insulated grounding conductors are acceptable. • Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green, or green with one or more yellow stripes. • The equipment grounding conductor is to be connected to ground at the service equipment. • The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type. • The equipment grounding conductors serving these receptacles are to be connected to earth ground at the service equipment. • A supplementary equipment grounding conductor shall be installed between the product or system and ground that is in addition to the equipment grounding conductor in the power-supply cord. • The supplementary equipment grounding conductor shall not be smaller in size than the ungrounded branch-circuit supply conductors. • The supplementary equipment grounding conductor shall be connected to the product at the terminal provided, and shall be connected to ground in a manner that will retain the ground connection when the product is unplugged from the receptacle. • The connection to ground of the supplementary equipment grounding conductor shall be in compliance with the rules for terminating bonding jumpers at Part K or Article 250 of the National Electrical Code, ANSI/NFPA 70. • Termination of the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any grounded item that is permanently and reliably connected to the electrical service equipment ground. • The supplemental grounding conductor shall be connected to the equipment using a number 8 ring terminal. • The terminal should be fastened to the grounding lug provided on the rear panel of the equipment. • The ring terminal should be installed using the appropriate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or equivalent).

2-4

TSU 600 User Manual

61202076L1-1