Page 81
Chapter 5. Configuration Menu
Creating a DSO Map To configure a DS0 Map, perform the following steps: Step
Explanation
1
Initialize the TEMP Map to one of three configurations (current Map A, current Map B, or all IDLE). This step is optional.
2
Edit the Temp Map so that it reflects the desired map configuration.
3
Replace the current DS0 Map A or B configuration with the Temp map configuration. Initializing the Temp Map Upon entering the DS0 maps CONFIGURATION menu, the Temp map reflects its last configured state.
61202156L2-1
If you want to...
Enter selections...
Initialize the Temp map from its current configuration to one which reflects the currently stored Map A or B configurations, respectively.
1-2
Initialize the Temp map to an all IDLE state.
3
TDU 120e User Manual
5-19
Page 82
Chapter 5. Configuration Menu
Editing the Temp Map If further changes to the TEMP map are needed, do the following: Step
Action
Explanation
1
Use selection 7 to enter the Upon entering this mode, the cursor Temp map edit mode. location moves to DS0 number one in the DS0 field of the Temp map.
2
Move the cursor from one Locate the DS0 number whose DS0 to another by using the assigned port needs to be changed. up and down arrows
3
Press Enter.
4
Use the up and down To restore the previous port arrows to scroll through the assignment and return to the DS0 field, possible port selections. press ESC.
5
To save the current selected port and return to the DS0 field, press Enter.
6
When the cursor is again located in the Temp map DS0 field, press Esc.
The cursor will move into the PORT field.
This causes the cursor to return to selection 1 below the Temp map display.
Applying the Temp Map Once the Temp map reflects the desired configuration, use selections 8 or 9 to apply this configuration to Map A or B, respectively. Copying Map To copy Map A to Map B, copy Map A to the Temp map and then apply the Temp map to Map B. See Figure 5-11.
5-20
TDU 120e User Manual
61202156L2-1
Page 83
Chapter 5. Configuration Menu
TEMP
DS0 A
DS0 B
Figure 5-11. DS0 Map Designations
Reviewing Maps Selections 4 through 6 give a summary of the number of ports assigned to Map A, Map B, and the Temp map, respectively. The menu items and their descriptions follow:
Copy Map A (B) to Temp Map Copies the current map A (B) into a TEMP map area. This permits modification without disturbing the existing map. When the modifications are completed, the TEMP map is written to current MAP A (B) by selecting APPLY TEMP MAP TO MAP A (B).
Create Temp Map Creates a map by defining a port or Idle for all DS0s. When CREATE TEMP MAP is first selected, all DS0s are set to Idle. Possible port selections include IDLE, TST, + option module ports. TST designates which DS0s are used for QRSS testing when activated under the TEST menu. When not used for testing, the TST designation is identical to IDLE.
61202156L2-1
TDU 120e User Manual
5-21
Page 84
Chapter 5. Configuration Menu
Selecting APPLY TEMP MAP TO MAP A (B) will not disrupt the operation of unmodified ports.
Review Map A (B) Permits a quick review of the number of DS0s assigned to each port and the number of unassigned DS0s (IDLE or TST) as defined in the currently applied Map A (B). Review Temp Map This menu item is operated the same as REVIEW MAP A (B). Edit Temp Map The map in the TEMP file can be edited to whatever configuration is desired. If Map A had been copied into the TEMP file, then after editing, the TEMP file could be applied to MAP A or MAP B. Apply Temp to Map A (B) Writes the TEMP map into Map A (B). Apply is usually the last step in updating a map.
Port Configuration (Port Config) PORT CONFIGURATION selects and configures the parameters associated with any data port in the unit. For example, parameters for the DS-1 (PBX) interface are set through this menu. The items that can be set depend on which option module is installed. The list of option ports will vary with the configuration. The TDU 120e is designed so that any additional ports developed in the future will contain the appropriate menu selections to provide access by using this menu item.
5-22
TDU 120e User Manual
61202156L2-1
Page 85
Chapter 5. Configuration Menu
The CONFIG menus for options ports are described in separate sections of the manual supplied with the option card. Nx/DBU (0.1) Menu Items The Nx/DBU port has two main menus: NX56/64 CONFIG -- Nx operation and DBU CONFIG -- DBU operation. Nx56/64 Config Under NX56/64 CONFIG, the menu items are:
DS0 RATE This sets the base DS0 rate of the interface. The actual data rate depends on the number of DS0s assigned to the Nx port. Choices: 56K OR 64K TX CLK CNTRL Controls the clock used by the TDU 120e to accept transmit (TX) data from the DTE. The default is NORMAL. If the interface cable is long, causing a phase shift in the data, the clock can be selected as INVERT. This switches the phase of the clock which should compensate for a long cable. Choices: NORMAL, INVERT DATA Used to control the inverting of the DTE data. This inversion can be useful when operating with an HDLC protocol. Often used as a means to ensure 1s density. Choices: NORMAL or INVERT
If INVERT is selected, zero (0) inhibit should also be selected to prevent an open DTE input from placing zeros on the network.
61202156L2-1
TDU 120e User Manual
5-23
Page 86
Chapter 5. Configuration Menu
CTS Used to control characteristics of CTS. Choices: NORMAL, (see Table 5-1 on page 5-25) or FORCE ON DCD Data Carrier Detect. Indicates to the DTE when a valid signal is being received at the Network Interface. Choices: NORMAL (see Table 5-1 on page 5-25) or FORCE ON DSR Data Set Ready. This signal indicates to the DTE when the DCE is turned on and ready for operations. Choices: NORMAL (see Table 5-1 on page 5-25) or FORCE ON “0” INHIB The Nx interface will detect an uninterrupted string of zeros (0s) being transmitted toward the network. If 0s are transmitted for more than 1 second, the TDU 120e will force 1s. Choices: ON or OFF INBAND MODE The Nx56/64 port is capable of providing an inband communications channel (for T-Watch PRO and SNMP) between units. This is accomplished by using 8 kbps of the first DS0 assigned to that particular Nx56/64 port. If in 56K mode, no data bandwidth will be used. Inband must also be enabled at the destination port. Choices: ON or OFF, ON DEMAND TX CLK SOURCE Controls the source of the clock used by the TDU 120e to accept transmit data from the DTE. The default option is INTERNAL. If the application requires that the DTE device provide the clock with the transmit data, the External setting is used. Choices: INTERNAL, EXTERNAL
5-24
TDU 120e User Manual
61202156L2-1
Page 87
Chapter 5. Configuration Menu
Table 5-1. Normal Mode of Operation RTS
V.54 511 TST Self Test Loopback ON Active CTS Follows OFF OFF DCD, - OFF DSR, OFF OFF Where “ - ” = don’t care Force On = On under all conditions
Netwk Test Active OFF, OFF
No DS0 Mapped OFF OFF OFF
Network Alarm OFF OFF, This table indicates conditions which cause the PORT CONTROL SIGNALS to be deactivated.
Dial Backup Config Under DBU CONFIG, the menu items are:
Backup Mode In a backup condition, both ends of the circuit must detect backup conditions before backup is activated. One DBU is set to ORIGINATE and the other to ANSWER. Upon a network failure, only the Originate DBU initiates backup by dialing the ANSWER END. Once called, the ANSWER DBU goes into backup mode only if a backup condition is detected. This is ideal for controlling where calls originate. Choices: DISABLE, ORIGINATE, ANSWER Backup On Selects the conditions that cause the Nx/DBU to initiate Backup. NET FAIL Backup occurs on RED ALARM, YELLOW ALARM, BLUE ALARM and LOS.
61202156L2-1
TDU 120e User Manual
5-25
Page 88
Chapter 5. Configuration Menu
NET/DATA FAIL Backup occurs on the same conditions as NET FAIL plus loss of data transitions on the data the Nx56/64 receives from the network. Pattern Verify Selects whether or not the DBU will use its pattern generator and receiver to authenticate backup attempts. When the local and remote units are both Nx/DBUs, set to ENABLE; otherwise set to DISABLE. Choices: ENABLE, DISABLE Backup Delay Selects the time allowed to elapse between the network going into alarm or no data transmissions and the backup beginning. Choices: 1 SEC, 3 SEC, 10 SEC, 30 SEC, 1 MIN, 5 MIN, 10 MIN Restore Delay Selects the time that elapses between the network going out of alarm or data being received and the backup call being taken down. If NEVER is selected, the user must deactivate the backup mode. Choices: 1 SEC, 3 SEC, 10 SEC, 30 SEC, 1 MIN, 5 MIN, 10 MIN, NEVER Retry Delay Selects the time between redialing the external DCE after failed dial attempts. Choices: 10 SEC, 30 SEC, 1 MIN, 5 MIN, 10 MIN Num Retries Selects the number of times the DBU will attempt to redial if unable to connect. Choices: NONE, UNLIMITED, 3 TIMES, 10 TIMES.
5-26
TDU 120e User Manual
61202156L2-1
Page 89
Chapter 5. Configuration Menu
Backup Testing Selects the options for the automatic ISDN verification feature of the Nx/DBU. Verification of the backup circuit does not disrupt data on the T1. Backup Test: Selects the frequency of automatic backup circuit verification by the DBU. Choices: MANUAL, HOURLY, DAILY, WEEKLY Test Hour: Selects the hour of the day the Backup test will occur. Choices: 0 - 23 Test Day: If weekly Backup test is selected, selects which day to perform the test. Choices: MONDAY - SUNDAY
WKEND Lockout If no backup is desired from midnight Friday to midnight Sunday, set this selection on ON; otherwise set to OFF. Choices: ON, OFF Enable HR: The hour backup will be enabled. Enter from the numeric keyboard. Choices: 0-23 Disable HR: The hour that the backup will be disabled. Enter from the numeric keyboard. Choices: 0-23
For these items to function properly, verify that the time and date in the TDU are set correctly. See page 6-2 for instructions on setting date and time.
61202156L2-1
TDU 120e User Manual
5-27
Page 90
Chapter 5. Configuration Menu
Trap in DBU: If traps are enabled (see UNIT CONFIGURATION), this parameter will send either a single trap upon going into a DBU session or send repeated traps for the duration of the DBU session. Choices: SINGLE, REPEATED
DS-1 (0.2) Menu Items Format Format sets the frame format for the base DS-1 interface. Choices: D4, ESF Code CODE sets the line code for the base DS-1 interface. Choices: AMI, B8ZS Yellow Alarm YELLOW ALARM enables and disables the transmitting of yellow alarms. Choices: ENABLE, DISABLE Line Length (ft) LINE LENGTH provides selection of the proper output level for the base DS-1 based on the length of the interface cable. Choices: SHORT HAUL INTERFACES (ft) - 1-133, 133-266, 266-399, 399533, 533-655 LONG-HAUL INTERFACES - 0dB -7dB, -15dB, -22dB, auto Inband Loopback (INBAND LPBACK) IN-BAND LOOPBACK sets the base DS-1 to accept or reject in-band loopup or loopdown codes (per ANSI T1.403 specification) which may be sent to the card over the DS-1 interface. This loopback is a line loopback. Choices: ACCEPT, REJECT
5-28
TDU 120e User Manual
61202156L2-1