Page 71
Chapter 5. Configuration Menu
Base DTE Timing The Base DTE is the source of timing. The TDU 120e uses the incoming DTE clock to determine the transmission timing. This is typically used in applications where it is necessary to have the DTE as the primary clock source (such as limited distance line drivers). See Figure 5-6.
INTERNAL OSCILLATOR T1 Transmit SECONDARY INTERFACE
NETWORK INTERFACE
OPTION CARD T1 Receive
BASE Nx56/64
BASE DS-1
DTE CLOCK
PBX
Figure 5-6. Base DTE Timed Clock Source
61202156L2-1
TDU 120e User Manual
5-9
Page 72
Chapter 5. Configuration Menu
Internal Timing The TDU 120e is the source of timing. The TDU 120e is configured to use its own internal oscillator as the source of timing. Applications include private line driver circuits where one end is set to network and the other to internal. See Figure 5-7.
INTERNAL OSCILLATOR T1 Transmit
SECONDARY INTERFACE
NETWORK INTERFACE
OPTION CARD T1 Receive
BASE Nx56/64
BASE DS-1
DTE CLOCK
PBX
Figure 5-7. Internal Clock Source
5-10
TDU 120e User Manual
61202156L2-1
Page 73
Chapter 5. Configuration Menu
Secondary Timing The secondary interface is the source of timing. The TDU 120e uses the clock derived by the secondary interface for transmission timing. See Figure 5-8.
INTERNAL OSCILLATOR
SECONDARY INTERFACE
T1 Transmit NETWORK INTERFACE
OPTION CARD
T1 Receive
BASE Nx56/64
BASE DS-1
DTE CLOCK
PBX
Figure 5-8. Secondary Clock Source
61202156L2-1
TDU 120e User Manual
5-11
Page 74
Chapter 5. Configuration Menu
Normal (CSU) Timing The typical timing option arrangement is shown in Figure 5-9. The PBX is looped timed sending data to the TDU 120e which is actually synchronous to the received data. The Network Interface (NI) is the actual source of all timings. This timing option is the same as that typically used for CSUs. It works equally well when the PBX is the source of timing. In that configuration the network would not be providing timing.
INTERNAL OSCILLATOR
NETWORK INTERFACE
SECONDARY INTERFACE OPTION CARD
PBX 1
T1 Transmit
T1 Receive BASE Nx56/64
BASE DS-1
DTE CLOCK
PBX 2
Figure 5-9. Normal (CSU)
The network interface and secondary interface clocking options are set by using the Network (NI) Configuration menu options.
5-12
TDU 120e User Manual
61202156L2-1
Page 75
Chapter 5. Configuration Menu
U-BR1TE The timing selection U-BR1TE works like NORMAL (CSU) except that timing is derived from the U interface on port 1.1. Set Line Buildout Selects the line buildout for the network interface. In AUTO mode, the TDU 120e sets the LBO based on the strength of the receive signal and displays the selected value. Choices: 0.0 dB, 7.5 dB, 15 dB, 22 dB, and Auto.
To activate the -36 dB receiver sensitivity, set the LBO to AUTO. This action is useful in a point-to-point application where no network elements are involved. If a network element such as a Smart Jack is installed on the circuit, the LBO should be set to 0 dB.
Remote Loopback Det Sets unit to accept or reject the network interface loop-up and loop-down codes as defined in ANSI T1.403. Choices: ACCEPT ALL, REJECT ATT, REJECT FT1, REJECT ATT & FT1, REJECT ALL. Bit Stuffing When enabled, bit stuffing causes the TDU 120e to monitor for ones (1s) density violations and insert a one (1) when needed to maintain 1s at 12.5%. Choices: ENABLE or DISABLE. TR-08 Options The TR-08 submenu configures the unit for TR-08 applications. The submenu items and their descriptions follow:
Alarm Report Enables and disables the transmission of alarm reports. Choices: SEND ALARMS, DISABLE ALARMS
61202156L2-1
TDU 120e User Manual
5-13
Page 76
Chapter 5. Configuration Menu
Alarm Format Sets the alarm format to 13 frames or 16 frames. Choices: ORB-13, ORB-16 BPV Threshold Sets the threshold for BPVs to trigger an alarm. Choices: 10-4, 10-5, 10-6 Exit This selection will exit to the main configuration menu.
Unit Menu The Unit menu changes the baud rate of the Control In port and the setup of the Dial Out port. The menu items are: Control Port Rate Sets the baud rate for communication with the PC or modem. Choices: 1200, 2400, 9600, 19200, and 38400 KBPS Traps Enables or disables the transmission of trap messages. Choices: ENABLE and DISABLE Access Sets the method of connection from the TDU 120e to T-Watch PRO or SNMP. Choices: Direct: Used if connected directly to the PC. Dial: Used when connection is through a modem. The dial string is entered from T-Watch PRO or SNMP. Init Modem Allows you to choose an industry standard or a custom initialization string for a modem connected to the control port. Choices: NONE, CUSTOM, HAYES, MOTOROLA, and USR COURIER
5-14
TDU 120e User Manual
61202156L2-1
Page 77
Chapter 5. Configuration Menu
Control Port Selects the TCP/IP physical interface: Normal (10BaseT Ethernet) or SLIP using the RS-232 serial port. Choices: NORMAL or SLIP
If the Control Port option is set to SLIP, the RS-232 port cannot be used as a terminal interface.
IP Address This is the IP address that uniquely identifies the TDU 120e on a TCP/IP network. This address is composed of four decimal numbers, each in the range of 0 to 255, separated by periods. This value is used for either the 10BaseT Ethernet or SLIP interface, depending on the control port setting. Subnet Address This defines which part of a destination IP address is the Network number. It is used along with the TDU 120e IP address to determine which nodes must be reached through the default IP Gateway. This value is set to 0.0.0.0 when the control port option is set to SLIP. Default Router All IP Packets destined for nodes not on the TDU 120e unit’s local network are not forwarded through this IP address. Normally, this address defines a router connected to the TDU 120e unit’s local network. This value is ignored when the control port option is set to SLIP. SLIP Rate This sets the baud rate for the Chain-In port when used as the SLIP connection for SNMP management. Choices: 1200, 2400, 9600, 19200, 38400
61202156L2-1
TDU 120e User Manual
5-15
Page 78
Chapter 5. Configuration Menu
SLIP Flow Control This is used to activate flow control on the Chain-In port when used as the SLIP interface. Hardware mode uses RTS and CTS. Choices: NONE, HARDWARE Proxy Traps This determines whether or not traps are forwarded to the IP Interface from units being “proxied” for. Choices: ENABLE, DISABLE External Alarm Sets unit to accept or reject external alarms attached to Pin 6 or Pin 7 of the Chain-In Port. A connection to ground indicates an alarm condition. Choices: ENABLE, DISABLE
Exit This selection will exit to the main configuration menu.
Map Exchange The MAP EXCHANGE menu enables and sets the automatic time of day map switch. The unit provides selection of the hour, minute, and seconds for the map switching to take place. The menu items are: OFF Indicates the map in use does not change. The automatic map change feature is disabled. AUTO Indicates that the map in use will change at a userselected time of day. The automatic map change feature is enabled. When AUTO is selected, the unit displays the screens to set times for switching.
5-16
TDU 120e User Manual
61202156L2-1
Page 79
Chapter 5. Configuration Menu
After editing Map A, press Enter to record the Map A settings and activate the selection fields for Map B. Use the same operation to edit switching time for Map B. When ESF is used with an FDL channel between units, the units automatically coordinate the automatic map switch by sending a map switch command from end-toend over the FDL. Only one end needs to be set to AUTO for this to work.
Map In Use This menu item controls the DS0 map the TDU 120e uses and displays the map in current use.
DS0 Map A and DS0 Map B The DS0 maps designate which DS0s are assigned to which port. The three maps are: DS0 Map A Default map. DS0 Map B Alternate map. Temp Temporary map used as a scratch pad.
61202156L2-1
TDU 120e User Manual
5-17
Page 80
Chapter 5. Configuration Menu
DS0 Maps Configuration Menu The DS0 maps configuration menu takes advantage of the 24-line VT-100 display. Upon entering this menu, the current Temp (temporary) map displays and is followed by nine selections that you can use for configuring and reviewing map information. See Figure 5-10. TEMP MAP DS0# 1 2 3 4 5 6 7 8 9 10 11 12
DS0# 13 14 15 16 17 18 19 20 21 22 23 24
PORT IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE
PORT IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE
1) COPY MAP A TO TEMP MAP 2) COPY MAP B TO TEMP MAP 3) CREATE TEMP MAP 4) REVIEW MAP A 5) REVIEW MAP B 6) REVIEW TEMP MAP 7) EDIT TEMP MAP 8) APPLY TEMP MAP TO MAP A 9) APPLY TEMP MAP TO MAP B
Figure 5-10. DS0 Temp Map You can use the up and down arrows or number keys to move the cursor from one selection to another. Press Enter to perform the action displayed to the right of the cursor.
5-18
TDU 120e User Manual
61202156L2-1