Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 15

TDU 120e User Manual, pages 91 to 100

Pages 91 to 100 of 146

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Adtran TDU-120

Page 91

Chapter 5. Configuration Menu

Robbed Bit Signaling This menu option is used to enable/disable robbed-bit signaling. Whenever the base DS-1 interface is connected to terminal equipment (e.g., PBX/SW56) for voice or dialed data services, this option should be enabled. Exception: When the terminal equipment is using a form of common channel signaling (e.g., PRI). For applications requiring robbed-bit signalling as well as a messaging channel (e.g., some proprietary PBX channels), the ON: ENA BLOCK selection is provided. Choices: OFF, ON: ALL DSOS, ON: ENA BLOCK RBS Start When Robbed Bit Signaling option is set to ON: ENA BLOCK, this item defines the first DS0 to extract signaling from. RBS End When the Robbed Bit Signaling option is set to ON: ENA BLOCK, this item defines the last DS0 to extract signaling from. Example: RBS Start and RBS End together define a block of DS0s for Robbed Bit Signaling.

61202156L2-1

TDU 120e User Manual

5-29

Page 92

Chapter 5. Configuration Menu

5-30

TDU 120e User Manual

61202156L2-1

Page 93

Utility Menu

Chapter 6 UTIL

The UTILITY menu displays and sets system parameters. See Figure 6-1. This includes setting the time and date, resetting all parameters to factory values, or reinitiating the unit. This menu also displays the unit software revision and the unit ID setting. TIME: HH:MM:SS 1) TIME/DATE

DATE: MM/DD/YY

(Returns all configurations 2) FACT RESTORE to factory settings)

3) SET PASSCODE

NEW PASSCODE

VERIFY PASSCODE

3) UTIL

4) UNIT ID

5) SOFTWARE REVISION

(Displays Current Software Revision)

6) PORT UTILITY

NX/DBU (0.1) DS-1 (0.2)

7) MAC ADDRESS

(OPTION PORTS)

Figure 6-1. Utility Menu Tree

61202156L2-1

TDU 120e User Manual

6-1

Page 94

Chapter 6. Utility Menu

Menu flow is depicted from left to right. At every level of the menu, press Escape to return the system to the previous menu level. Pressing Escape repeatedly returns the system to the Main menu.

Time/Date This menu option displays or edits the current time and date. The TDU 120e maintains the time and date during power-off conditions. If you want to...

Do this...

Record a numeric change

Press Enter (this records the entry and moves to the next editing position)

Move to a different field to edit

Press Enter at the editing position without making any changes, or use the up and down arrow keys.

End the editing process

Press Escape.

Factory Restore There are two ways to execute a factory restore -- through the menus and by holding the ACO button down during power-up. The factory restore menu item restores the factory default settings for all unit parameters, including configured DS0 maps. The CONTROL PORT RATE, PASSCODE, UNIT ID, and IP PARAMETERS are not affected by the FACTORY RESTORE command. A factory reinitialization can also be executed by holding the ACO button down during power-up. All factory options including control port rate, Pass code, Unit ID, and IP parameters are restored to factory settings with this procedure. During a factory reinitialization, the Remote LED will turn on. The Remote LED will turn off after the factory reinitialization is complete. The ACO button may be released at this time.

6-2

TDU 120e User Manual

61202156L2-1

Page 95

Chapter 6. Utility Menu

Set Passcode Change/Set a Passcode The passcode can be changed or set at any time or eliminated altogether through the Utility menu item SET PASSCODE. The passcode can be numeric only. After entering the desired passcode, press Enter. Set a null passcode at the SET PASSCODE menu by pressing Enter without any numbers. This sets a null passcode and grants unlimited access. Lost Passcode If the passcode number is lost, contact ADTRAN Technical Support for assistance (see page xi of this manual). No Passcode Desired At the NEW PASSCODE prompt (in the Set Passcode menu), press Enter without any numerical entry. The system nullifies the need to enter a password for subsequent use and proceeds to the Unit ID prompt.

If the unit is to be remotely accessed using T-Watch PRO, a passcode must be entered. When managing a number of units, the passcode can be the same for all.

Unit ID This menu is used to access the current UNIT ID setting. Viewing is available in limited access mode. Editing or changing the UNIT ID requires the use of a password as in editing mode. Unit Identification numbers must be between 2 and 999. If an out-of-range number is entered, the unit assumes the upper limit number of 999.

61202156L2-1

TDU 120e User Manual

6-3

Page 96

Chapter 6. Utility Menu

To Set the Unit Identification In the UNIT ID menu under the UTIL menu, enter any value between 2 and 999. The number 1 is reserved for the PC. Pressing Enter records the Unit ID number and establishes its availability for operation by remote control. The unit proceeds to the SET CONTROL PORT prompt. No Unit ID Desired Without entering any numbers at the Unit ID prompt, press Enter. Pressing Enter with no Unit ID recorded establishes the unit as not able to be operated by remote control.

Software Revision This menu provides access to the display of the current software revision level loaded into the base unit controller. This information is required when requesting assistance from ADTRAN Technical Support or when updates are needed. Press Escape to exit.

Port Utility This menu provides access to the display of the current software information for each port installed in the unit. This information is required when requesting assistance from ADTRAN Technical Support or when updates are needed.

MAC Address Displays the Ethernet Mac address for the 10BaseT port.

6-4

TDU 120e User Manual

61202156L2-1

Page 97

Chapter 7

Test Menu

TEST The TEST menu initiates different types of unit tests and displays test results. The TEST menu contains four items. See Figure 7-1. 1) NETWORK INTR LBKS 1) NETWORK TESTS

LINE ON

LINE ON

PAYLOAD

PAYLOAD ON

ANSI FDL PLB

NO LOOPBACK

ANSI FDL LLB

2) LOCAL LOOPBCK 3) REMOTE LOOPBCK

ATT INBAND LLB

ANSI FT1 LLB NO LOOPBACK

ALL ONES 5) TEST

3) TEST PATTERN

ALL ZEROS

QRSS ALL DS0S

QRSS PATTERN

QRSS TST DS0S NONE

ES 4) PATTERN RESULT

BES SES

2) RUN SELF-TEST

(displays results)

3) PORT TEST

NX/DBU (0.1)

1) DTE LOOPBACK

SYNC

2) 511 PATTRN 3) 511 RESULTS

4) CANCEL TESTS

(displays results)

4) DBU LOOPBACK

TESTS OFF

5) DBU TEST

FORCE BACKUP INTERFACE TST

6) DBU DATA CNTRL

(display results)

7) DBU TST RESULT

(display results)

DS-1 (0.2)

1) LOOPBACK

(OPTION PORTS)

PORT LOOPBACK LINE LOOPBACK

Figure 7-1. Test Menu Tree

61202156L2-1

TDU 120e User Manual

7-1

Page 98

Chapter 7. Test Menu

Executing tests will disrupt some of the normal operation. See individual menu items concerning tests before executing.

Menu flow is depicted from left to right. At every level of the menu, pressing Escape returns the system to the previous menu level. Pressing Escape repeatedly returns the system to the MAIN menu.

Network Tests Network tests control the activation of loopbacks and the initiation of data test patterns. Network tests are run on the Network Interface (NI). You can select three different test configurations to determine the type of loopback and the pattern to run. Test results display in the LCD window.

Executing Network Tests will disrupt normal data flow unless only TST DS0s are selected for testing.

Loopback Tests A number of different loopbacks can be invoked locally from the front panel, by T-Watch PRO commands, or remotely by using special in-band codes (AT&T D4 network loop-up and loop-down codes). Additionally, the loopbacks can be remotely controlled by means of out-ofband commands by the T1 ESF FDL or from T-Watch PRO by a modem connection.

7-2

TDU 120e User Manual

61202156L2-1

Page 99

Chapter 7. Test Menu

Network Interface Loopbacks Network interface loopbacks affect the entire T1 data stream. See Figure 7-2. The two types of network loopbacks are: Line Loops all of the received data back toward the network. The transmitted data is the identical line code that was received, including any bipolar violations or framing errors. Payload Similar to line loopback, except that the framing is extracted from the received data and then regenerated for the transmitted data.

TDU 120e NI CSU Secondary Interface

DS1 Payload Loopback Line Loopback

Figure 7-2. Network Loopback Tests

Local Loopback There are three available choices for setting the local loopback: Line On Activates the line loopback. Payload On Activates the payload loopback.

61202156L2-1

TDU 120e User Manual

7-3

Page 100

Chapter 7. Test Menu

No Loopback Deactivates the loopback. Scroll to select a setting and press Enter to record the setting. Remote Loopback Activates the same loopbacks as LOCAL LOOPBACK, but at the far end. Uses either the inband loopup code as specified by ANSI T1.403 for line loopback (ATT In-Band LLB), or the FDL as specified in ANSI T1.403 for payload and line loopback codes. The following options are available: ATT In-Band LLB Activates the line loopback using inband code. ANSI FDL PLB Initiates the transmission of an FDL payload loopup code toward the far end. ANSI FDL LLB Initiates the transmission of an FDL line loopup code toward the far end. ANSI FT1 LLB Initiates the transmission of an FT1 loopback using the inband code described in T1.403. No Loopback Deactivates the loopback.

Remote Loopback can only be used with Fractional T1 if the ANSI FT1 LLB is selected.

7-4

TDU 120e User Manual

61202156L2-1