Page 101

Chapter 7. Test Menu

After a REMOTE LOOPBACK option is selected, the TDU 120e verifies that the far end is actually in a loopback by checking for the receipt of a code looped back from the far end. Once the REMOTE LOOPBACK type is selected, the terminal displays the loopback progress by displaying LOOPING until loopback is verified. Test Patterns All Ones Sends an all ones pattern to the network. All Zeros Sends an all zeros pattern to the network. QRSS Pattern The QRSS pattern is commonly used to simulate real data in T1 interfaces. This pattern can be assigned to appear in all DS0s or only in TST DS0S. When QRSS is set in all DS0s and one of the network loopbacks previously described is activated at the far end, a total end-toend integrity check can be run without the need for any external test equipment. When QRSS is assigned to TST DS0S, an integrity check of the link can be run along with normal data flow. The TST DS0S are user assigned as part of the DS0 Map. This sets the pattern for the test and initiates the transmission of the pattern. The test is terminated by selecting NONE. The following patterns are available: QRSS All DS0s Generates a QRSS test pattern and inserts the pattern into all DS0s.

61202156L2-1

TDU 120e User Manual

7-5

Page 102

Chapter 7. Test Menu

QRSS TST DS0s Inserts a QRSS pattern in those DS0s mapped as TST in the currently active map (A or B). None Terminates pattern generation.

QRSS always runs at 64K/DS0.

Instructions for Generating a QRSS Test Pattern Step

Action

1

Select QRSS ALL DS0s.

2

Press Enter to record the selection. The TDU 120e starts to generate a QRSS test pattern and inserts the pattern into all DS0s.

3

To end the test, select None.

Pattern Result Displays the results of the test currently active. Leaving and returning to this menu item does not interrupt the test. Pressing 2 injects errors into the test pattern. These errors are detected by the device performing the pattern check. ES The number of seconds with at least 1 bit error. BES The number of seconds with more than 1 bit error and less than 320.

7-6

TDU 120e User Manual

61202156L2-1

Page 103

Chapter 7. Test Menu

SES The number of seconds with more than 320 bit errors. *SYNC Indicates if pattern sync is (YES) or is not (NO) valid. The asterisk (*) indicates if pattern sync has been lost since the start of testing. Clear results by pressing C. The results are accumulated until the test pattern is set to NONE or CLEARED. Using TST DS0s for testing can be very useful, particularly in Fractional T1 applications. How to Run an End-to-End Test on Fractional DS0s Step

Action

1

Set the TST for Map B in the same DS0 as used by Map A to receive data from an Nx56/64 port.

2

Loop the far end using a V.54 loopback code on the Nx56/64 port.

A single DS0 can be used for continuous testing while other DS0s are passing normal data. This will also provide an end-to-end check on the entire link. Set each end to send QRSS in TST DS0s (using 1 DS0) and occasionally view the results on the Pattern Result menu selection.

61202156L2-1

TDU 120e User Manual

7-7

Page 104

Chapter 7. Test Menu

Run Self-Test The self-test checks the integrity of the internal operation of the electronic components by performing memory tests and by sending and verifying data test patterns through all internal interfaces. Although actual user data cannot be passed during these tests, the self- test can be run with the network and DTE interfaces in place and will not disturb any external interface. The memory portion of the self-test automatically executes upon power-up. A full self-test can be commanded from terminal/telnet menu or from T-Watch PRO. In addition to the specified self-tests, background tests are also run on various parts of the internal electronics. These run during normal operation to confirm continued correct functioning. This menu selection is used to execute a full internal selftest. The results of the self-tests are displayed on the terminal. Upon invoking the command, the terminal displays System Self-Test and the Test LEDs are illuminated. Test failures are displayed on the terminal. The self-test consists of the following: Test Name

What it does...

Board level tests Each of the TDU 120e boards contains an onboard processor which executes the following series of tests checking the circuitry on the board: • RAM tests; EPROM checksum • DS0 map tests • On-board data path (sending a known test pattern through an on-board loop) Unit level tests

Unit level tests consist of: • Front panel LED verification • Phase Lock Loop verification • Board-to-board interface test

7-8

TDU 120e User Manual

61202156L2-1

Page 105

Chapter 7. Test Menu

A test pattern is sent from the controller through a loopback on all other boards and is checked on the controller. This verifies the data path, clocks, and control signals. If a failure is detected, note the failure number prior to contacting ADTRAN Technical Support (see page xi of this manual).

The execution of the self-test will disrupt normal data flow and prevent remote communication until the self-test is completed.

Port Tests The PORT TESTS menu is used to activate testing of specific data ports. It controls the activation of loopbacks and the initiation of data test patterns. Test results are displayed on the terminal screen.

The execution of Port Tests will disrupt normal data flow in the port being tested.

Nx/DBU (0.1) Menu Items Nx/DBU (0.1) is the base Nx interface. It offers the following test functions: DTE LOOPBACK This initiates a loopback. The following options are available:

REMOTE The remote loopback causes a V.54 code to be sent to the far end. The Nx at the far end activates a PORT/LOCAL loopback upon detection of the V.54 code.

61202156L2-1

TDU 120e User Manual

7-9

Page 106

Chapter 7. Test Menu

OFF The loop is deactivated.

REM V.54 Cont. The remote loopback causes a continuous V.54 code to be sent to the far end. The Nx at the far end activates a PORT/LOCAL loopback upon detection of the V.54 code. The TDU 120e checks the remote loopback activation by detecting a proper response from the remote end. While waiting for the response, the display shows Looping. If successful, the display changes to Looped-Up. If unsuccessful, the display shows Failed.

511 PATTRN Activates the generation of the 511 test pattern.

ON The pattern check circuitry is enabled and a test started. The test is ended by selecting OFF.

OFF The pattern generation and check is disabled. 511 RESULTS Displays the results of the 511 test indicated in the 511 option. The results are in the form of the number of errored seconds. The error count can be cleared by pressing C. DBU LOOPBACK

ON Initiates a loopback from the DBU towards the external DCE.

OFF Terminates the loopback test. DBU TEST This selection is used to force a backup to occur even if a backup condition does not exist.

7-10

TDU 120e User Manual

61202156L2-1

Page 107

Chapter 7. Test Menu

TEST OFF Turns off DBU tests. FORCE BACKUP Forces a backup regardless of time-of-day lockouts or network conditions. INTERFACE TST Causes the external DCE to dial its stored number. After the connection is established, the DBU sends a test pattern to verify the backup network. This test does not disrupt data or the primary network. DBU DATA/CNTRL Allows status of DCD and RI to be monitored while the INTERFACE TST is on. If the dial up network is correctly configured and dialed up, there should be an asterisk (*) over DCD. DBU TST RESULT When an interface test is active, this screen will show the total number of DATA blocks received and the number of blocks with errors. DS-1 (0.2) Menu Items Loopback LOOPBACK activates the loopback function on the base DS-1 interface. The available loopbacks are:

Port Loopback Towards the NI. Line Loopback Towards the PBX or other terminal equipment.

Cancel Tests Use this menu selection to deactivate all active tests, including tests on option modules.

61202156L2-1

TDU 120e User Manual

7-11

Page 108

Chapter 7. Test Menu

7-12

TDU 120e User Manual

61202156L2-1

Page 109

Chapter 8

Remote/Management Menus The REMOTE/MANAGEMENT menu initiates Telnet/terminal sessions with remote devices and displays various management information.

REMOTE MENU ACCESS This menu displays Telnet menus for a remote device (may be another TSU/TDU or any other ADTRAN product that supports Telnet via its EIA-232 chain port). After selecting this option, the user may choose to connect to a device entered in the Unit Access Table or enter a unit ID for a unit not in the Unit Access Table. CTRL + X terminates the session and returns to the TDU 120e Main menu.

MANAGEMENT CONFIGURATION This menu sets management information, such as SNMP community names and trap destination addresses.

61202156L2-1A

TDU 120e User Manual

8-1

Page 110

Chapter 8. Remote/Management Menus

UNIT ACCESS TABLE This menu edits/creates the Unit Access Table and stores the Unit ID, Passcode, and Unit Type for units connected via chain ports or connected remotely to the TSU/TDU (see Figure 8-1). An entry in the table is required only to support proxy SNMP MIB access or polling. For MIB access, an entry is required only if the unit's passcode is not the same as the DEFAULT UNIT PASSCODE, or the unit is a single port TSU Standalone.

It is not necessary to have an entry in this table for a remote unit in order to Telnet to it or forward SNMP traps from it. In the Telnet case, the Remote Menu Access menu is selected from the Main menu and a unit ID is entered which may or may not be in the Unit Access Table.

Units accessed via T-Watch PRO over TCP/IP use the unit ID and passcode set by T-Watch PRO running on the PC. ____________________________Unit Access Table________________________ Unit ID

Passcode

Type

Polled

20

DEFAULT

Standard

No

3

0033

Standard

Yes

6

0095

TSU Standalone

No

8

0022

Standard

Yes

Poll Status UP

UP

1) Add New Unit 2) Modify Unit 3) Delete Unit 4) Default Unit Passcode 0022 5) OK

Figure 8-1. Unit Access Table

8-2

TDU 120e User Manual

61202156L2-1A