Page 41

Chapter 2. Installation

At this point, the unit initialization procedure is concluded. If the unit is to be configured remotely, there are no additional items necessary to complete prior to executing remote configuration. The Passcode, the Unit ID, and the Control Port settings are stored in a nonvolatile memory. This ensures they are operable for subsequent power-up sequences.

NORMAL POWER-UP PROCEDURE After the unit has been put into operation with the initial power-up and initialization, subsequent power-up procedure includes only the Power-Up self-test followed by the request for a passcode (password) if this option was selected during initialization. Type the previously recorded passcode and press Enter.

61202156L2-1

TDU 120e User Manual

2-11

Page 42

Chapter 2. Installation

2-12

TDU 120e User Manual

61202156L2-1

Page 43

Operation

Chapter 3

MENU OPERATION The TDU 120e uses a VT-100 type terminal to display control and monitor menus. Initiate this mode by keying in <CTRL> PTT on the terminal once it is connected to the Control In or Craft port. When you begin the Telnet session, you will be prompted for a password. The default password is ADTRAN. You can change this password using the MANAGEMENT submenu. For detailed information on this method of control, see the Telnet/Terminal Main Menu on page 3-5. You can also connect to the TDU 120e via Telnet. Before attempting to connect via Telnet, first define the IP address, the default gateway, and the subnet mask. See DEFAULT UNIT PASSCODE in the Unit Access Table on page 8-2 for details. The Telnet session will time-out after a predefined value that is also set in the MANAGEMENT menu.

Only one Telnet session can be active at one time.

61202156L2

TDU 120e User Manual

3-1

Page 44

Chapter 3. Operation

Sample Terminal Screen with TDU 120e Menu An example of a PC screen with a TDU 120e menu is shown in Figure 3-1. Main Menu 1) Status 2) Config 3) Util 4) Test 5) Remote Menu Access 6) Management Config 7) Flash Download 8) Quit Session Command: Figure 3-1. Sample Terminal Screen with TDU 120e Menu

General Menu Traversal The TDU 120e uses a multilevel menu structure containing both menu items and data fields. All menu operations and data are displayed on the terminal. Select and Activate a Menu Item To choose a menu item, place the cursor on the desired menu item by:

3-2

• pressing the number corresponding to the menu item, or

• using the up and down arrows.

TDU 120e User Manual

61202156L2

Page 45

Chapter 3. Operation

The following steps and Figure 3-2 describe how to activate the alarm list option from the Status Menu. Step

Action

Result

1

Activate the STATUS menu using The cursor will flash on the the arrow keys or by pressing 1. number next to the activated selection.

2

Press Enter.

3

Use the arrow keys to view submenu items.

4

Choose an item on the submenu The cursor will flash on the such as ACTIVE ALARMS. number next to the activated selection.

5

Press Enter.

6

View the ALARM LIST.

The STATUS submenus will display.

The ACTIVE ALARM LIST will display.

.

1) NETWORK (NI) PERFORMANCE REPORTS 2) NETWORK (NI) ERRORS

STATUS

3) ACTIVE ALARMS

(ALARM LIST)

4) VIEW HISTORY

END OF LIST

5) PORT STATUS 6) REMOTE PORT 7) CLEAR PORT ALARM 8) ETHERNET STATUS Figure 3-2. Example of Basic Menu Travel

61202156L2

TDU 120e User Manual

3-3

Page 46

Chapter 3. Operation

Edit the Data Field You can edit data fields preceded by a colon (:). To edit a data field perform the following steps: Step

Action

Result

1

Position the cursor on the submenu The cursor moves to the data item number and press Enter. field (to the right of the submenu item name).

2

Using the space bar, scroll to scan the available value settings.

The value settings display one-at-a-time in the data field position.

3

When the desired value is displayed in the data field position, press Enter to set that value.

When the value is set, the cursor moves back to the submenu item position.

4

Select another submenu field or press Escape to return to the submenu.

This indicates the operation is complete.

Exit Any Menu Field Operation or Display Press Escape as many times as required to return to the desired menu level.

Data Port Identification When configuring the unit, menu selections will include options from data port submenus. Selecting data ports is necessary because the TDU 120e uses a Slot-Port method to identify the data port the menu item is referencing. If a module containing a PBX DSX-1 option card with an Nx56/64 plug-on interface is installed in the option slot, it would be designated as: DSX-1 Passthru (1.1) Where slot=1 and port=1. The DSX-1 is located in the option slot and is the first port in that slot. Nx56/64 (1.2) Where slot=1 and port=2.

3-4

TDU 120e User Manual

61202156L2

Page 47

Chapter 3. Operation

The Nx is located in the option slot and is the second port in that slot. The ports that are built into the TDU 120e are referenced as Slot 0. The Nx/DBU is designated as 0.1 and the DS-1 is referenced as 0.2.

MENU STRUCTURE Telnet/Terminal Main Menu The TDU 120e uses a multilevel menu structure containing both menu items and data fields. All menu operations and data display in the terminal window. The first menu displayed after the Telnet/terminal session is established is the MAIN menu. See Figure 3-3. The default Telnet/terminal password is ADTRAN.

ADTRAN - TDU 120e Password: XXXXXX Main Menu 1) Status 2) Config 3) Util 4) Test 5) Remote Menu Access 6) Management Config 7) Flash Download 8) Quit Session Figure 3-3. Telnet/Terminal Main Menu

61202156L2

TDU 120e User Manual

3-5

Page 48

Chapter 3. Operation

Only one Telnet/terminal session may be active at a time.

Menu Options The opening menu is the access point to all other operations. Each MAIN menu item has several functions and submenus to identify and access specific parameters. Status Displays all relevant information for the network and DTE interfaces. For detailed information on status options, see Chapter 4, Status Menu. Config (Configuration) Displays and sets the TDU 120e operational configuration, including all network interface parameters, the allocation of the DS0s, and the port parameters. For detailed information on configuration options, see Chapter 5, Configuration Menu. Util (Utilities) Displays and sets system parameters. For detailed information on utility options, see Chapter 6, Utility Menu. Test Initiates different types of unit tests and displays test results in the terminal window. For detailed information on test options, see Chapter 7, Test Menu. Remote Access Menu Displays Telnet menus for a remote device. For detailed information, see Chapter 8, Remote/Management Menus.

3-6

TDU 120e User Manual

61202156L2

Page 49

Chapter 3. Operation

Management Configuration Displays management information. For detailed information, see Chapter 8, Remote/Management Menus. Flash Download Allows you to manually perform a Flash download. For detailed information, see Chapter 8, Remote/Management Menus. Quit Session Terminates the Telnet/terminal session.

FRONT PANEL The TDU 120e front panel monitors operation and controls the configuration of the unit. The TDU 120e front panel is shown in Figure 3-4.

TDU 120e AC REMOTE ACCESS

NETWORK

MON

CRAFT IN

OUT

IN

OUT

PORT 0.2 IN

OUT

MON IN

OK

RED

OK

TEST

YEL

TEST

ALARM

ERROR

ALARM

OUT

PORT 1.1 IN 0.1

ACO

0.2

1.1

1.2

NETWORK STATUS

PORT STATUS

Network Status LED's

Port Status LED's

1.3

OUT

MON IN

OUT

1.4

Alarm Cut Off Control Port Active Unit

Connection For Network Terminal Monitor Jack

DS-1 Monitor Jack

Port 1.1 Option Card Monitor Jacks

Figure 3-4. TDU 120e Front Panel Layout

The following pages contain descriptions of each part of the front panel.

61202156L2

TDU 120e User Manual

3-7

Page 50

Chapter 3. Operation

ACO Switch The Alarm Cut-Off (ACO) switch deactivates the alarm relay after an alarm condition has occurred. If the alarm that activated the alarm relay is cleared, then reoccurs, the alarm relay will re-energize.

Remote LED The remote LED (yellow) indicates a management session (terminal mode or Telnet) is active. The LED does not activate (turn on) during SNMP sessions.

Craft Port The Craft Port is used as an RJ-45 port to connect the unit to a computer, a modem, or to another TDU/TSU multiplexor or a TSU 100.

Network Monitor Jack This jack connects the unit to the network.

DS1 Monitor Jack This jack connects the unit to a PBX or other terminal equipment.

3-8

TDU 120e User Manual

61202156L2