Page 31
Installation
Chapter 2
UNPACK, INSPECT, POWER UP Receipt Inspection Carefully inspect the TDU 120e for any shipping damages. If you suspect damage, file a claim immediately with the carrier and then contact ADTRAN Customer Service (see the front section of this manual for contact information). If possible, keep the original shipping container for use in shipping the TDU 120e back for repair or for verification of damage during shipment.
ADTRAN Shipments The following items are included in the ADTRAN shipment:
61202156L2-1
•
The TDU 120e
•
2-line interface cables: A 15-foot, 8-position modular to 8-position modular
•
A DB-25 to modular adapter
•
A 6-foot, 8-position modular cable for connection to the chain-in port
•
The user manual
TDU 120e User Manual
2-1
Page 32
Chapter 2. Installation
Customer Provides •
Cables for any expansion modules to be used with the TDU 120e
•
10BaseT cable for connection to a LAN or router (if you plan to use remote management features)
POWER CONNECTION AC Powered Units Each TDU 120e AC unit is equipped with a captive eightfoot power cord, terminated by a three-prong plug which connects to a grounded power receptacle.
Power to the TDU 120e AC unit must be from a grounded 90-120 VAC, 50/60Hz source.
DC Powered Units Each TDU 120e DC unit is provided with a two-pin power receptacle and mating plug. Power to the TDU 120e DC unit is + 48 VDC or +24 VDC.
2-2
TDU 120e User Manual
61202156L2-1
Page 33
Chapter 2. Installation
GROUNDING INSTRUCTIONS Grounding instructions from the Underwriters' Laboratory UL 1950 3rd Edition are provided in this section. An equipment grounding conductor that is not smaller in size than the ungrounded branch-circuit supply conductors is to be installed as part of the circuit that supplies the product or system.
61202156L2-1
•
Bare, covered, or insulated grounding conductors are acceptable.
•
Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green, or green with one or more yellow stripes.
•
The equipment grounding conductor is to be connected to ground at the service equipment.
•
The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type.
•
The equipment grounding conductors serving these receptacles are to be connected to earth ground at the service equipment.
•
A supplementary equipment grounding conductor shall be installed between the product or system and ground that is in addition to the equipment grounding conductor in the power supply cord.
•
The supplementary equipment grounding conductor shall not be smaller in size than the ungrounded branch-circuit supply conductors.
•
The supplementary equipment grounding conductor shall be connected to the product at the terminal provided and shall be connected to the ground in a manner that will retain the ground connection when the product is unplugged from the receptacle.
TDU 120e User Manual
2-3
Page 34
Chapter 2. Installation
•
The connection to ground of the supplementary equipment grounding conductor shall be in compliance with the rules for terminating bonding jumpers at Part K or Article 250 of the National Electrical Code, ANSI/NFPA 70.
•
Termination of the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any grounded item that is permanently and reliably connected to the electrical service equipment ground.
•
The supplemental grounding conductor shall be connected to the equipment using a number 8 ring terminal.
•
The terminal should be fastened to the grounding lug provided on the rear panel of the equipment.
•
The ring terminal should be installed using the appropriate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or equivalent).
Do not use this product near water, such as in a wet basement.
For DC-powered devices, the supply power for the product must be installed near the equipment and be easily accessible.
2-4
TDU 120e User Manual
61202156L2-1
Page 35
Chapter 2. Installation
IDENTIFICATION OF REAR PANEL LAYOUT Figure 2-1 shows the configuration of the rear panel of the TDU 120e (AC powered and DC powered units).
TDU 120e AC
TDU 120e DC
Figure 2-1. TDU 120e Rear Panels
61202156L2-1
TDU 120e User Manual
2-5
Page 36
Chapter 2. Installation
TDU 120e Interfaces The TDU 120e rear panel is equipped with an Nx/DBU data port, a DS-1 interface, an option slot, management interfaces, an external alarm connector, and a T1 interface. See Figure 2-2.
10BaseT PC or Modem
Network
PBX
Control Chain Input Output
Chain Input
NI TDU 120e
NI TDU 120e
Chain Output
DS-1
DS-1
Nx56/64 Option
Nx56/64 Option
V.35
DS-1
V.35
Figure 2-2. TDU 120e Interfaces
Network Interface The Network Interface (NI) port provides the connection to the T1. This port complies with the applicable ANSI and AT&T standards. For more information see Appendix B. Nx56/64 Serial Interface The Nx56/64 provides a serial V.35 port that operates from 56 kbps to 1.536 Mbps. This port provides 511 pattern generation and detection and remote loopback capability.
2-6
TDU 120e User Manual
61202156L2-1
Page 37
Chapter 2. Installation
DS-1 (PBX) Interface The DS-1 interface provides a T1 for a PBX or other equipment. This port complies with ANSI T1.102. It can be software configured for either long-haul or short-haul. Control In Port The control port input provides an RJ-45 input from a PC or a modem for control of the TDU 120e. You can also use it as a chain input from another TDU 120e or TSU 100. For more information, see Appendix B. Craft Port The craft port provides the same functionality as the Control Port Input. Both the craft port and the control port input may be connected simultaneously, but only one port may be active at a time. For more information, see Appendix B. Control Out Port The chain port output provides an RJ-45 output to chain control to other TDUs or to TSUs. For more information see Appendix B. 10BaseT Interface The 10BaseT interface provides the LAN interface for managing the TDU 120e with SNMP or T-Watch PRO. For more information, see Appendix B. External Alarm Connector The external alarm connector provides the capability of connecting an external alarm device to the TDU 120e. The alarm relay will activate on any alarm. The relay will remain activated until the automatic cut-off (ACO) button on the front panel is pushed. For more information, see Appendix B.
61202156L2-1
TDU 120e User Manual
2-7
Page 38
Chapter 2. Installation
POWER UP TESTING When shipped from the factory, the TDU 120e is set to factory default conditions. At the first application of power, the unit automatically executes a memory self-test. A full self-test can be run from the terminal. A passcode and unit ID may be set using the UTILITY menu. See page 6-3.
Self-Test When... Initiating a self-test
Then... The terminal displays System Self-test Now Testing and Memory Test Now Testing. The test LEDs are illuminated.
The self-test is completed All LEDs go back to their normal state. The terminal momentarily displays System Self-test Tests passed. A failure is detected
A list of failures is displayed on the terminal. The full self-test procedure (invoked from the terminal or T-Watch PRO) consists of the following tests:
Type of Test Board level tests
Explanation The TDU 120e contains an on-board processor which executes a series of tests checking the circuitry on the board. RAM and EPROM tests Verify on-board circuitry
Unit level tests
Front panel LED verification Board-to-board interface test A test pattern is sent from the controller through a loopback on all other boards and checked on the controller. This verifies the data path, clocks, and control signals for the entire chassis.
2-8
TDU 120e User Manual
61202156L2-1
Page 39
Chapter 2. Installation
INITIALIZATION Set User Passcode The TDU 120e is designed to operate with or without the use of a passcode. The default condition is without a passcode.
If the unit is to be remotely accessed using T-Watch PRO, you must enter a passcode. When managing a number of units, the passcode can be the same for all the units.
The passcode should be a number easily remembered. Once entered, the passcode is required to access any operation other than viewing. See Set Passcode on page 6-3 for details.
Set Unit Identification The UNIT ID sets the unit to respond to remote control (controlled by a device other than the front panel or terminal). If no Unit ID is recorded it is not possible to operate from any remote control device, including the local PC for T-Watch PRO or SNMP. See Unit ID on page 6-3 for details.
Set Control Port The TDU 120e can be configured from the control port when T-Watch PRO, SNMP, or the terminal interface are being used. If the control port is to be used, the control port baud rate must also be selected.
61202156L2-1
TDU 120e User Manual
2-9
Page 40
Chapter 2. Installation
Chain In (PC) The unit can be controlled from an external PC connected directly or via modem to the Chain-In port. When using Chain-In, the selection of the Control Port baud rate from 9600 (factory default), 1200, 2400, or 4800, 19200, or 38400 must be made using the UNIT CONFIGURATION menu. See Unit Menu on page 5-14 for details.
Chain In/Chain Out TDU 120e units and other TDUs and TSUs can be linked together to form a chain. Figure 2-3 provides an example of a chain-in arrangement with a PC or a modem. The first TDU 120e in the chain receives controlling input from the PC or modem.
PC or Modem
Control Input
Chain Out
TDU 120e
Chain In
Chain Out
TDU 120e/ TSU 100/TSU
Chain In
Chain Out
TDU 120e/ TSU 100/TSU
Figure 2-3. Example of Chain-in
Subsequent TDU/TSUs in the chain are in a position to intake information from another TDU or TSU. This in-taking of information from another TDU in the chain is identified as Chain In. The baud rate for the chained units must match that of the first unit. Unless locked out externally, the front panel can also control the unit.
2-10
TDU 120e User Manual
61202156L2-1