Page 21
List of Figures Figure 1-1. TDU 120e Option Modules ..................................................................1-5 Figure 1-2. Bridge, PBX, Video Conferencing Application Set-up.....................1-6 Figure 2-1. TDU 120e Rear Panels ..........................................................................2-5 Figure 2-2. TDU 120e Interfaces ..............................................................................2-6 Figure 2-3. Example of Chain-in ...........................................................................2-10 Figure 3-1. Sample Terminal Screen with TDU 120e Menu ................................3-2 Figure 3-2. Example of Basic Menu Travel ............................................................3-3 Figure 3-3. Telnet/Terminal Main Menu ...............................................................3-5 Figure 3-4. TDU 120e Front Panel Layout .............................................................3-7 Figure 4-1. Status Menu Tree ...................................................................................4-1 Figure 4-2. Network Interface Performance Report.............................................4-2 Figure 5-1. TDU 120e Config Menu Tree ...............................................................5-2 Figure 5-2. Network (NI) Menu Tree.....................................................................5-3 Figure 5-3. Unit Menu Tree .....................................................................................5-4 Figure 5-4. Network Timed Clock Source .............................................................5-7 Figure 5-5. Base DS-1 Timed Clock Source............................................................5-8 Figure 5-6. Base DTE Timed Clock Source ............................................................5-9 Figure 5-7. Internal Clock Source..........................................................................5-10 Figure 5-8. Secondary Clock Source ..................................................................... 5-11 Figure 5-9. Normal (CSU) ......................................................................................5-12 Figure 5-10. DS0 Temp Map ..................................................................................5-18 Figure 5-11. DS0 Map Designations .....................................................................5-21 Figure 6-1. Utility Menu Tree ..................................................................................6-1 Figure 7-1. Test Menu Tree.......................................................................................7-1 Figure 7-2. Network Loopback Tests......................................................................7-3 Figure 8-1. Unit Access Table ..................................................................................8-2
61202156L2-1
TDU 120e User Manual xxi
Page 22
List of Figures xxii
TDU 120e User Manual
61202156L2-1
Page 23
List of Tables Table 4-1. Alarm Message Display ........................................................................ 4-4 Table 5-1. Normal Mode of Operation................................................................ 5-25 Table 8-1. Unit Access Table Commands ............................................................ 8-3 Table B-1. Network Pinout of the 8-Pin Modular Connector ............................ B-1 Table B-2. Network Pinout of the Male 15-Pin D-Connector ............................ B-2 Table B-3. Control In/Chain In Pinout ................................................................. B-2 Table B-4. Chain-Out Pinout .................................................................................. B-3 Table B-5. Craft Port Pinout.................................................................................... B-4 Table B-6. V.35 Pinout for Nx56/64 DTE ............................................................. B-5 Table B-7. Base DS-1 Pinout of the 8-Pinout Modular Connector ....................B-6 Table B-8. Base DS-1 Pinout of the 15-Pin Female D-Connector....................... B-7 Table B-9. 10BaseT Ethernet Connector ................................................................ B-8 Table B-10. External Alarm Device Connector .................................................... B-8 Table B-11. Power Connector (DC powered units)............................................. B-8
612022156L2-1
TDU 120e User Manual xxiii
Page 24
List of Tables xxiv
TDU 120e User Manual
612022156L2-1
Page 25
Introduction
Chapter 1
TDU 120e OVERVIEW The TDU 120e is a T1/FT1 multiplexer with the following features: •
Nx56/64 V.35 data port
•
DS-1 (PBX) interface
• option slot
• embedded SNMP management
The TDU 120e’s option slot accepts one of many available option modules for voice and data applications. The TDU 120e serves as the link between user data sources such as: • local area network (LAN) bridges and routers
• computers
•
CAD systems
• teleconferencing equipment
•
PBXs
Through the use of multiple data ports, the TDU 120e can simultaneously connect one or more of these devices to a T1 circuit. The amount of bandwidth allocated to each port is custom-programmable. You can manually allocate bandwidth or set the bandwidth to change automatically at predetermined times to use the available bandwidth most advantageously. Changes in the configuration do not disrupt data flow in channels that are not being reconfigured. The unique architecture and the availability of
61202156L2-1A
TDU 120e User Manual
1-1
Page 26
Chapter 1. Introduction option modules provides a path for growth to accommodate future requirements. The TDU 120e offers a wide variety of network management options. The 10BaseT and control ports are compatible with both SNMP and T-Watch PRO management. An enhanced VT-100 terminal interface is also provided.
1-2
TDU 120e User Manual
61202156L2-1A
Page 27
Chapter 1. Introduction
Standard Features in the TDU 120e The following list describes the standard features in the enhanced TDU 120e.
61202156L2-1A
•
A single T1 interface.
•
An Nx/DBU V.35 port and a DS-1 (PBX) interface.
•
An inband communication channel requiring only 8k of bandwidth from a single DS0.
•
One option slot to house option modules with up to four additional ports, including voice and data.
•
Allows mix of port types to meet the data interface requirements.
•
Easy configuration capabilities using simplistic menus displayed on a terminal or computer connected to the control port on the rear of the unit or the craft port on front of the unit.
•
Two programmable configuration maps that define the bandwidth allocation between data ports.
•
Data drop and insert, as well as full drop and insert.
•
Flash memory for software updates.
•
Timing is selectable from the network, from the Nx56/64 or DS-1 ports, internally, or from a secondary interface.
•
QRSS; 511 test patterns using Nx option.
•
Extensive self-testing and monitoring provides assurance of proper operation.
•
SNMP, Telnet, and T-Watch PRO management via SLIP or 10-BaseT
•
Ability to proxy for “agentless” units
•
Enhanced terminal mode
•
Fractional T1 loopbacks as defined in Annex B of ANSI T1.403-1995
•
Software configurable long-haul or short-haul DS-1 port
•
External alarm connector
•
External alarm monitor
TDU 120e User Manual
1-3
Page 28
Chapter 1. Introduction
TDU 120e OPTION MODULES Some of the option modules available for the TDU 120e are: DSX-1 Provides a short haul T1 interface for operation with a PBX (Terminal Interface). Full Drop and Insert Permits the dropping of data and insertion of new data into the same DS0 time slot. This module includes a long haul DS-1 interface. It can also be used as a second DS-1 interface to provide an up to 3 MB aggregate throughput. Nx56/64 serial interface Provides a V.35 serial interface in either single or dual versions. Voice interface Provides 2 or 4 channels FXS/FX0/E&M. OCU DP Interfaces to DDS or 4-wire Switched 56, dual or single versions. DSU DP Provides two sync or async ports (EIA-232 or V.35). Dial backup Allows for backup of data upon network T1 failure. U-BR1TE Allows ISDN lines to be extended over a T1 line.
1-4
TDU 120e User Manual
61202156L2-1A
Page 29
Chapter 1. Introduction
Option Module Architecture The TDU 120e features a unique architecture that allows the addition of one option module and plug-on board providing an opportunity for growth to accommodate another application. See Figure 1-1.
DSX-1 Module
TDU 120e REMOTE ACCESS
ACO
CRAFT
NETWORK IN
OUT
MON PORT 0.2 IN
OUT
IN
OUT
MON IN
OK
RED
OUT TEST ALARM
YEL ERROR
NETWORK
OK
TDU 120eAC
TEST ALARM
STATUS
0.1
0.2
PORT 1.1 1.1
PORT STATUS
1.2
1.3
1.4
IN
OUT
MON IN
OCU-DP Module
Plug on V.35
V.35 Module
Plug on OCU DP
OUT
D&I Module DUAL Voice
Plug on Dual Voice
Figure 1-1. TDU 120e Option Modules
61202156L2-1A
TDU 120e User Manual
1-5
Page 30
Chapter 1. Introduction
TDU 120e CONFIGURATION APPLICATIONS The following examples illustrate possible configurations of TDU 120e applications.
Router, PBX, Video Conferencing Application In this application, the Base Nx/DBU provides a V.35 interface to a router. The PBX is interfaced to the TDU 120e with the Base DS-1 interface. An OCU DP module and OCU DP plug-on board provide two switched 56 circuits for video conferencing. The 10BaseT port allows SNMP network management over the LAN. See Figure 1-2. PBX
TDU 120e
REMOTE ACCESS
ACO
CRAFT
NETWORK IN
OUT
MON PORT 0.2 IN
OUT
IN
OUT
MON IN
OK OUT
RED
TEST ALARM
YEL ERROR
NETWORK
OK
TDU 120eAC
TEST ALARM
STATUS
0.1
0.2
PORT 1.1 1.1
PORT STATUS
1.2
1.3
1.4
IN
OUT
MON IN
OUT
ROUTER
10 BaseT LAN
VIDEO CONFERENCING
SNMP NETWORK MANAGEMENT WORKSTATION
Figure 1-2. Bridge, PBX, Video Conferencing Application Set-up
1-6
TDU 120e User Manual
61202156L2-1A