The text of a manual · part 2 of 3

Data Collection Terminal Hardware Manual, pages 11 to 20

Pages 11 to 20 of 28

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Acroprint Datalog

Page 11

(For RS485 terminals only) Select option 1 for RS485 <press ENTER> Select the baud rate 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600 and 4 for 19,200 baud. <press ENTER> (For Ethernet terminals with ATR9800 only) Select option 2 for Ethernet <press ENTER> Select the baud rate option 3 for 9600 baud <press ENTER> (Leave this as the default for Ethernet.) Select the TCPIP address <press ENTER> (Your network administrator will have this information.) Select the GATEWAY address <press ENTER> (Your network administrator will have this information.) Select the PORT VALUE <press ENTER> (Default number 10001. Select the same value in the ATR9800 software.) Select the NETMASK VALUE <press ENTER> (Your network administrator will obtain this information. The Network SubNetMask TCPIP number contains 4 elements of numbers separated by “.”. To determine the NETMASK VALUE obtain your Network SubnetMask IP number from the Network administrator, i.e. XXX.255.255.000. Convert the last three elements (your numbers will be different) to binary and count the total number of zero’s in each binary element and enter this number. 255 = 11111111 in binary, 000 = 00000000. Each 255 contains NO zeros therefore the Netmask value bits number is set to 08 for the example XXX.255.255.000.) The Ethernet terminal Netmask values can range from 01 to 24. Select the TERMINAL TRANSACTION PRINTER TYPE <press ENTER> (default is parallel port)

Ports and connections 11

Page 12

Select TRANSACTION TIME OUT <press ENTER> (This controls how long the terminal will restrict between badge swipes. Example: You want to keep your employees off the terminal for at least 30 minutes for lunch, then set Transaction Time Out to 30.) Select TERMINAL ID <press ENTER> (default is 1, select the ID for terminal, each terminal MUST have a unique ID) The terminal MUST be powered down and back up to accept the new TCPIP information.

Configuring procedure for selecting the READERS: Swipe the Configuration Badge 000000000 (This badge is provided with each terminal.) (Select any combination 1234 to activate the readers. 1 for Internal Barcode, 2 for External Barcode, 3 for Internal Magnetic Stripe and 4 for Internal Proximity Reader) Note, if 4 is selected then the External Barcode Reader will be disabled. Note, if you turned OFF all readers you will be unable to read the configuration badge. The following procedure will allow you to re-enable the readers. Press the IN, then the OUT and then the ENTER key within 1 second. The terminal will go into a testing mode. Press the Clear key, press the IN key, then the OUT key and then the ENTER key within 1 second or before the time is displayed.

12 Ports and connections

Page 13

Ethernet port The Ethernet port is located on the lower left corner of the terminal. It is a 10 position 8-pin female port which will accept a male 10BASE-T (RJ-45) modular connector. The terminal has the capability to communicate across an intranet, a WAN or the Internet. Note: Ethernet communicates via TCPIP 10BASE-T only.

ND WA RS 485

RS 232

9V

Ports and connections 13

Page 14

RS-232 Serial port The RS-232 serial port is located on the lower left corner of the terminal. It is a 6 position 4-pin female port which will accept a male RJ-11 modular connector.

ND WA RS 485

The Acroprint Data Collection Terminal can use RS-232 serial communication to connect directly to a host computer. A connection for an IBM PC or compatible is shown below.

RS 232

9V

Cabling to Host Computer with DB-25 Port (Use DB-25 RS-232 Host Cable Assembly. See page 26.)

DB-25 to RJ-11 Adaptor (Adaptor A) "Standard" Modular Cable

Schematic NOTE: Schematic connections are shown from END VIEW. (As viewed from the outside of the connectors.) Schematic

Cabling to Host Computer with DB-9 Port (Use DB-9 RS-232 Host Cable Assembly. See page 27.)

DB-9 to RJ-11 Adaptor (Adaptor A) "Standard" Modular Cable

Schematic NOTE: Schematic connections are shown from END VIEW. (As viewed from the outside of the connectors.)

14 Ports and connections

Schematic

Page 15

RS-232 Serial printer cables The terminal serial port is used for connection to a serial printer. Printers, such as the serial printer shown on page 24, use a circular DIN connection. The Serial DIN Cable is shown below (see page 26).

Cabling to serial printer with 6-pin DIN port DIN connector

72-0158-002

Serial DIN Cable Schematic NOTE: Schematic connections are shown from END VIEW. (As viewed from the outside of the connectors.)

Ports and connections 15

Page 16

Local Area Network: RS-485 serial port The RS-485 serial port is located on the lower left corner of the terminal. It is a 6 position 4-pin female port which will accept a male RJ-11 modular connector.

ND WA RS 485

RS 232

9V

The terminal can use RS-485 2-wire serial communication, allowing up to 32 terminals to be connected to one host port. An RS-232 port on the host is typically used in conjunction with an RS-232/RS-485 converter to complete the connection. Through software, the host can communicate with individual terminals even though they are wired in parallel. RS-485 communication uses a differential bus which provides good protection from interference over long runs of up to 4000 feet. NOTE: When wiring a network, always follow the electric wiring codes in your area. Typically, a teflon coated wire is required for wiring through the ceiling. The junction box to junction box wire shown on the opposite page is a teflon jacketed cable.

16 Ports and connections

Page 17

RS-485 Serial cables Junction Box “Daisy Chain” Wiring Diagram

4 5

+

+

+

3

+

4 2

5

+

+

+

3

+

4 2

5

Junction Box To another Junction Box

+

+

+

3

+

2

Junction Box

Teflon Cable

Junction Box To terminal (short as possible) "Standard" Modular Cable

"Reversed" Modular Cable

Schematic

Schematic

DB-25 to RJ-11 Adaptor (Adaptor C) Schematic

NOTE: Connectors are shown from END VIEW. (As viewed from the outside of the connectors.)

RS-232 to RS-485 Converter

To serial port on host computer

Ports and connections 17

Page 18

Modem port Terminals which are equipped with a MODEM port, will not have an RS-485 port. The MODEM port, when installed, physically replaces the RS-485 port and occupies the same location - the lower left corner of the badge terminal. It is a 6 position 4-pin female port which will accept a male RJ-11 modular connector.

ND WA RS 4MO8D5EM RS 232

9V

The internal modem (modulator/demodulator) converts electronic data into tones which are then transmitted over phone lines. The modem is compatible with Bell 103/212A and CCITT V.21/V.22 devices. It supports both asynchronous and synchronous (SDLC) communication and can communicate with a host computer over phone lines at 300, 1200, and 2400 baud.

18 Ports and connections

Page 19

Modem cables The cabling for modem operation is typically very simple. The modular connection uses the two inner wires of the RJ-11 jack for “tip” and “ring.” Connect one end of the cable to the terminal and plug the other end into your RJ-11 type modular telephone wall jack. If a modular wall jack is not available, obtain an adaptor from your local telephone company.

“Standard” Modular Cable

Schematic

Ports and connections 19

Page 20

Wand port The Wand port is located on the lower left corner of the terminal. It is a 6-pin DIN port which will accept a circular DIN connector.

ND WA RS 485

RS 232

9V

The Wand, when connected, uses only 3 of the 6 pins available on the DIN connection. If a Bar Code Gun (non-contact reader) is used, the center pin supplies additional power. The terminal uses 2 of the remaining pins as logic lines for external controls. See pin-out and function table below: Pin 1 2 3 4 5 6

Function 6 1 +5 Volts 5 Signal control logic line (special) Bar Code Wand receive data 2 GND 4 3 Access logic line (special) END VIEW 9 Volt unregulated 6-pin DIN jack (maximum current draw 220 mA)

20 Ports and connections