Page 1
Data Collection Terminal
0
-10-0
M 04
A 8:20
QZ. 1 GHI 4 PRS 7
IN
ABC 2 JKL 5 TUV 8 -SP 0
DEF 3 MNO 6 WXY 9
OUT
AR
CLE
K BAC E C SPA HA
ALP
ER
ENT
HARDWARE MANUAL
Page 2
FCC Warning: Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, it may cause interference with the radio and television reception in a residential area, in which case the user will be required to correct the interference at his or her own expense. If this equipment causes interference, try to correct the problem by:, Reorienting the receiving antenna., Relocating the terminal with respect to the receiver with which it interferes., Plugging the terminal into a different AC outlet, and putting the terminal and receiver on different branch circuits. FCC Compliance: (on hardware equipped with modem) This equipment complies with Part 68 of FCC Rules. Upon request, furnish the following information to the telephone company (telco)., Manufacturer: Acroprint Time Recorder Co., Inc., Model: Badger II Terminal, FCC registration number: 4G3USA-21602-DT-E, Ringer equivalence: 0.7B, USOC modular telephone jack: R-J11 Lithium Battery Caution: This circuit board on this terminal is populated with a lithium battery to protect data or programs stored in the Random Access Memory (RAM). Do not, under any circumstances, attempt to replace the lithium battery in the terminal. Failure to comply may invalidate your warranty. Battery replacement should be done by qualified personnel wearing the proper eye protection. CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instruction. Declaration Of Conformity According To EMC Directive 89/336/EEC We declare under our sole responsibility that the magnetic stripe and/or bar code reading and/or data recording equipment Badger II 01-0119-000/003/ 005/007 to which this declaration relates are in conformity with the following standards: EN55022:1987, EN50082-1, IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5. I, the undersigned, hereby declare that the equipment specified above conforms to the above directive and standards. Raleigh, North Carolina October 7, 2002
USA
All Rights Reserved. © COPYRIGHT 1996 Acroprint Time Recorder Company
2
W. Glenn Robbins
Page 3
Table of Contents 1. Introduction ................................................................. 4 Basic hardware and variations ................................................ 4 General specifications ............................................................. 5 2. Setup ............................................................................ 6 Site requirements .................................................................... 6 Unpacking and inspection ...................................................... 6 Mounting ................................................................................ 7 Power up ................................................................................. 7 3. Operator interface ....................................................... 8 ADCT Keypad ........................................................................ 8 DataLog Keypad ..................................................................... 8 Card reader ............................................................................. 9 4. Ports and connections ............................................. 10 Acroprint Data Collection Terminal setup instructions ........ 10 Ethernet port ......................................................................... 13 RS-232 Serial port ................................................................ 14 RS-232 Serial printer cables ................................................... 15 Local Area Network: RS-485 serial port .............................. 16 RS-485 Serial cables ............................................................. 17 Modem port .......................................................................... 18 Modem cables ....................................................................... 19 Wand port ............................................................................. 20 Wand and Y-Cable ................................................................ 21 Parallel port........................................................................... 22 Parallel cable ......................................................................... 23 5. Companion products ................................................ 24 Printer ................................................................................... 24 Readers ................................................................................. 24 Power Supplies ..................................................................... 25 External Relay Box, External Buzzer ................................... 25 Cables ................................................................................... 26 Cables, Converter, Badge Racks........................................... 27
Table of Contents
3
Page 4
1. Introduction Basic hardware and variations The electronic hardware is a new, versatile platform designed for use with various applications. This manual describes, in detail, the electronic hardware aspects of the terminal you have purchased. The details concerning terminal firmware and host software are addressed in the manual which comes with the software. All terminals are equipped with: 1) a magnetic stripe reading head 2) a 2 row x 20 character per row display 3) a 16-key full travel keypad 4) an RS-232 serial port 5) a wand port for optional bar code wand 6) two control lines for external relay control (door access, and bell ringer are typical applications) 7) a 25-pin parallel port The terminal is offered in different hardware variations. Listed below are the variations by part number and description: Part #
Description
C - Programmable e-prom (DataLog) 01-0120-000 DataLog with LAN (RS-485) 01-0120-002 DataLog with Modem (no LAN) 01-0120-003 DataLog with LAN & Internal Visible Bar Code Reader 01-0120-004 DataLog with Modem & Internal Visible Bar Code Reader 01-0120-005 DataLog with LAN & Internal Infrared Bar Code Reader 01-0120-006 DataLog with Modem & Internal Infrared Bar Code Reader 01-0120-008 DataLog with Ethernet 01-0120-010 DataLog with Ethernet & Internal Visible Bar Code Reader 01-0120-012 DataLog with Ethernet & Infrared Bar Code Reader Acrocomm e-prom (Acroprint Data Collection Terminal, ADCT) 01-0147-000 Acroprint with LAN (RS-485) 01-0147-002 Acroprint with Modem (no LAN) 01-0147-003 Acroprint with LAN & Internal Visible Bar Code Reader 01-0147-004 Acroprint with Modem & Internal Visible Bar Code Reader 01-0147-005 Acroprint with LAN & Internal Infrared Bar Code Reader 01-0147-006 Acroprint with Modem & Internal Infrared Bar Code Reader 01-0147-008 Acroprint with Ethernet 01-0147-010 Acroprint with Ethernet & Internal Visible Bar Code Reader 01-0147-012 Acroprint with Ethernet & Infrared Bar Code Reader
Note: The part number of your unit can be found on the serial number label on the back of the terminal. 4
Introduction
Page 5
General specifications A. Enclosure: 8.7 in. (23 cm) wide x 6.1 in. (16 cm) tall x 2.3 in. (6 cm) deep. “Clamshell” construction of 0.125 in. (3 mm) thick Polycarbonate/ABS injection molded flame retardant plastic. Includes reversible mounting bracket and access door which protects I/O ports. B. Multilayer main logic board with internal ground and power planes. C. Z-180 Microprocessor. D. Up to 512 Kbyte configurable memory. Most common configuration is 64K ROM and 128K RAM. E. Lithium battery backed RAM. F. Real Time Clock Chip on-board. G. Magnetic card reader: Track 2 ABA recording head for reading standard “Credit Card” format through the slot. H. Display: 2 lines with 20 characters on each line. ADCT is backlit. I. Keypad: Full travel keys with elastomeric contact pad, 4 rows x 4 columns. J. Serial Port: RS-232 using 6 position (4 contact) RJ-11 modular connection. K. Serial Port: RS-485 (Local Area Network) using RJ-11 modular connection. L. Parallel port: 25-pin DB connection. M. Internal Modem: Bell 212A (1200bps) and 103 (300bps) , CCITT V.22 bis (2400 bps) and V.22 (1200 bps), asynchronous, licensed for use over public telephone lines. N. Internal Multi-Frequency Piezo Electric Buzzer. O. Internal Bar Code Reader: Visible or Infrared Bar Code reading through the slot. P. Control lines: Two pins of the 6-pin circular DIN connector can be used with external relay box to control devices such as door locks and bells. Q. External Bar Code port: 6-pin DIN connection for external Bar Code Wand or Bar Code Gun. R. Power: Wall mount transformer, 9 Volts AC/DC 800 mA minimum or 10 Volts AC/DC 700 mA minimum, with female secondary plug size 2.1 x 5.5 mm.
Introduction
5
Page 6
2. Setup Site requirements The terminal can be installed in any normal office or controlled factory environment. However, do not use the terminal under the following conditions: • extremely high or low temperature [operating temperature range: 0° to 50° C (32° to 122° F)] [storage temperature range: -20° to 60° C (-4° to 140° F)] • extremely high or low humidity [operating humidity range : 0 to 90% RH non-condensing] • areas of high dust concentration • areas with chemical fume concentration • areas with extreme vibration or when placed on an unstable or unlevel surface Unpacking and inspection Having opened the shipping carton, carefully remove the contents. Inspect the terminal and accessories for damage. Report damage or shortages to the company from which the unit was purchased. Complete the registration card with all important information.
8:20
-10-00
AM 04
QZ. 1 GHI 4 PRS 7
IN
ABC 2 JKL 5 TUV 8 -SP 0
DEF 3 MNO 6
AR
CLE
BACK CE SPA HA
WXY 9
ALP
OUT
ENT
ER
(1) Terminal
(1) Power Supply
Data Collection Terminal
8:20
10-00
AM 04-
QZ. 1 GHI 4 PRS 7
IN
ABC 2 JKL 5 TUV 8 -SP 0
DEF 3 MNO 6 WXY 9
OUT
CLEAR BACK SPACE ALPHA
ENTER
HARDWARE MANUAL
(4) Mounting Screws
6
Setup
(1) Manual
Page 7
Mounting Unscrew the access door. With the door off, the main unit can be slid upward and removed from the mounting bracket. The bracket can be used for wall mounting, or it can be reversed to tilt the unit on a desktop.
Power up Plug in the power cord coming from the wall mount transformer into the terminal. Reattach the access door and secure the unit to the reversible bracket. Replace screw on the access door. NOTE: Other connections are made in the same fashion. Notice the channels in the bracket available for cable routing. Also, the bracket has through-holes for further securing of cables using ties.
Setup
7
Page 8
3. Operator interface ADCT Keypad The terminal has 16 keys for entering alphabetical and numeric data as illustrated below.
QZ. 1
ABC 2
DEF 3
CLEAR
GHI 4
JKL 5
MNO 6
BACK SPACE
PRS 7
TUV 8
WXY 9
ALPHA
IN
-SP 0
OUT
ENTER
DataLog Keypad The terminal has 16 keys for entering data as illustrated below.
1 4 7
8
Operator interface
2 5
3 6
8 0
9
CLEAR MENU
MENU ENTER
Page 9
Card reader The terminal has an internal magnetic stripe card reader. The magnetic stripe on the card should be on the right side when the card is swiped as shown below. Bar Code - left side
Magnetic stripe right side
0.25" Nominal
Optionally, the terminal can also have an internal bar code reader. The card is swiped through in the same fashion, but the Bar Code should be on the left side of the card when swiped.
1.00" Min.
NOTE: For through-the-slot reading, Bar Code should be located on card as shown. Operator interface
9
Page 10
4. Ports and connections Acroprint Data Collection Terminal setup instructions Configuring procedure for entering the DATE & TIME: Swipe the Configuration Badge 000000000 (This badge is provided with each terminal) Select option 1 for DATE <Press ENTER> Select the Day, Month, Year DDMMYYYY <Press ENTER> Select the Time HH:MM <Press ENTER> (Time is entered in military time, 2:00 pm = 14:00) Configuring procedure for selecting PORTS: Swipe the Configuration Badge 000000000 (This badge is provided with each terminal.) Select option 2 for Ports <press ENTER> Select option 0 for RS232 <press ENTER> Select the baud rate 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600 and 4 for 19,200 baud. <press ENTER> (For modem terminal only) Select option 1 for Modem <press ENTER> Select the Modem baud rate 0 for 1200 and 1 for 2400 baud <press ENTER> Select the Answer Window HHMMHHMM for starting and ending times <press ENTER> (time is in military format, Example: Clock will not answer during business hours and only answer between the hours of 8:00 pm and 6:00 am, then select 20000600.)
10 Ports and connections