Page 49
Chapter 2: Installation
Connections
Connecting the Module The DIDO modules come equipped with Phoenix Contact PCB terminal block(s) to connect wiring to the DIDO module. You may disconnect the terminal block(s) from the module then connect the wiring for the appropriate module as described in the previous section. Plug the terminal block back into the module as shown in Figure 2-19 (single module) or Figure 2-20 (dual module).
Figure 2-19
Connecting the PCB Block on a Single DIDO Module
Figure 2-20
Connecting the PCB Blocks on a Dual DIDO Module
DIDO 1
DIDO 2
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
2-17
Page 50
Connections
Chapter 2: Installation
Hand-Held CCD Scanner If you have an optional ATS hand-held CCD scanner (Part Number 9000/39), plug its cable into the Wand Socket on the Maximus Main Board as shown in Figure 2-21.
Figure 2-21
Connecting a Hand-Held CCD Scanner
WiFi External Antenna The optional WiFi module comes with two antenna. One ships connected to the module and mounted to the outside of the Maximus outer case. A second antenna, equipped with a 5meter cable (Part Number 17-7005-00), provides flexibility for locations with poor WiFi reception. Use the following procedure to install the 5-meter antenna:
Figure 2-22
2-18
1.
Disconnect the factory installed antenna from the WiFi module.
2.
Route the 5-meter antenna into the Maximus terminal and connect it to the WiFi module as shown in Figure 2-22.
3.
Move the antenna to the strongest signal strength and secure it by removing the protective paper on adhesive back on the antenna then attaching the antenna to a wall or other stationary structure.
Installing the 5-Meter Cable Antenna
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 51
Chapter 2: Installation
Power Connection
Power Connection A Maximus requires 12VDC power for operation. There are three ways to power the terminal: •
Power Pack - The ATS power pack plugs into an AC electrical wall outlet and delivers DC power to the 12VDC socket on the terminal main board.The outlet must be within 4 feet of the terminal to accommodate the length of the length of the ATS power pack cord.
•
Through-the-network wiring using IEEE 802.3af-compliant power over Ethernet (requires installation of PoE option and PoE-enabled network). For more information, see "Power over Ethernet" on page 2-19.
•
UPS Battery – The optional UPS battery backup system provides power if there is an interruption in power from the wall outlet/Power Pack or PoE.
Choose the power source that is best suited to your installation.
Power Pack When using a power pack, terminal power is supplied by plugging the output cable from an ATS 12VDC power pack directly into the DC Power connector on the back of the terminal. Ensure that a conventional 120VAC wall outlet (220VAC in Europe and other areas, check local electrical code requirements) is available to accept the power pack. The power pack can be plugged into a wall outlet within four feet (1.2m) of the terminal’s location and the cord from the power pack plugged into the back of the terminal.
Figure 2-23
Connecting the Power Pack to the 12VDC Socket
Power over Ethernet
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
2-19
Page 52
Power Connection
Chapter 2: Installation
If you are planning to use Ethernet communication, the Maximus can receive its power through a network that supports IEEE 802.3af power over Ethernet (PoE). The Maximus must have the PoE option installed. PoE does away with the need for a separate power supply and power wiring. The Maximus supports both end-span and mid-span PoE configurations.
Figure 2-24
Connecting the PoE Module to Powered Ethernet
Connecting the UPS Battery Maximus terminals can be equipped with an optional UPS battery system that supplies power to the terminal in the event of an electrical power outage. ATS disconnects the UPS battery pack prior to shipping to prevent the battery pack from discharging in case of extended storage periods.
NOTE:
If the battery backup option is installed, the terminal operates for approximately 1.5 hours after the primary voltage source is lost. After this, the terminal turns off. When the terminal is in battery backup mode, the yellow low-power indicator LED is lit by default. The battery option includes a charger board, which is a circuit board that installs in the terminal case and electrically connects the battery with the terminal’s main board. See the documentation included with the charger board for installation instructions. •
A ribbon cable attaches J2 on the charger board to J9 on the Global Series main board.
•
A cable connects the battery to J3 on the charger board.
After providing power to the Maximus terminal you may connect the battery pack. Connect the UPS Battery plug to the battery charger board as shown in Figure 2-25 (If the power-overEthernet (PoE) option is present, the battery backup connector is under the PoE board).
2-20
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 53
Chapter 2: Installation
Figure 2-25
Power Connection
Connecting the Battery Pack
The charger board has an LED, D3. The LED has three states: blinking, lit steadily on, and off. •
Blinking – Indicates the battery is being fast charged. It takes about seven hours to completely charge a fully drained battery.
•
Steady – If the LED is lit steadily on:
•
MANU-MAXIMUS-02 Revision-02
•
The battery is fully charged
•
The battery is too discharged to use fast charge, and a trickle charge is being applied before charging can switch to fast charge
•
The temperature is too high or too low to permit charging
Off – The LED is off when the terminal is using battery power. The LED only blinks or lights steadily when supplied with AC power.
Maximus Reference Manual
2-21
Page 54
Power Connection
Chapter 2: Installation
This page intentionally left blank.