The text of a manual · part 6 of 25

Maximus Reference Manual: Installation, pages 41 to 48

Pages 41 to 48 of 214, from Maximus Reference Manual

The original document is the PDF (18 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Ceridian MXS2100 and Accu-Time MXS2100

Page 41

Chapter 2: Installation

Figure 2-6

Terminal Installation

Installing the Mounting Base (with the terminal separated) Mounting Screws “Started” on the Wall

Figure 2-7

Wall Mounting the Maximus (terminal not separated) Mounting Screws “Started” on the Wall

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

2-9

Page 42

Terminal Installation

Chapter 2: Installation

6.

If you separated the terminal from the mounting base, reinstall the terminal on the base by reinstalling the terminal’s hinge screws or by sliding the fixed hinge pin into its mating top hole, lifting the lower spring-loaded pin, and pivoting the terminal until the pin drops into its mating hole. ("Terminal Wiring Access" on page 2-5).

7.

If you unplugged any cables between the terminal and base, reconnect them as they were originally.

Main Components This section provides the locations of the main components inside the Maximus terminal. Figure 2-8 shows the main components and modules locations with a Power over Ethernet module installed.

NOTE:

Figure 2-8

Power over Ethernet modules are typically not installed with a GSM or Serial module installed. Figure 2-8 and Figure 2-9 illustrate locations only and does not represent functionality or available configurations.

Maximus Component Locations (1) DIDO Module

Option Module (e.g., GSM, Serial)

Main Board Battery Charger Board

UPS Battery

PoE Module

Card Swipe Reader

Biometric Reader Area

Figure 2-9 shows the main components and modules with a WiFi module and an Accu-Touch Biometric reader installed (the PoE and WiFi module use the same location in the terminal.

2-10

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 43

Chapter 2: Installation

Figure 2-9

Terminal Installation

Maximus Component Locations (2)

WiFi Module Proximity Reader Board

Biometric Reader (Accu-Touch)

Main Board Components Figure 2-10 shows the locations of the main components and connectors on the main board.

Figure 2-10

Maximus Main Board Connectors Display Power Connector

Display Cable Connector

Option Board Connector

Reader Connector (12V default) Debug/Console Connector

RTC Battery

Beeper /Speaker 5V Reader Connectors

Wand Socket / DIDO 2 12VDC Socket DIDO 1 /Auxiliary Serial Port

Screen Contrast Control

Standard Ethernet Socket Reboot Button

Battery Board Connector

MANU-MAXIMUS-02 Revision-02

Beeper Volume Control

Maximus Reference Manual

Biometric Connector

USB Ports

2-11

Page 44

Connections

Chapter 2: Installation

Connections This section tells you how to connect the terminal communication and option wiring. The battery backup option, if present, is mounted in the terminal base. Your terminal may not have these options.

Standard Ethernet Connection When using an Ethernet connection, the Maximus terminal can be located at any point in a TCP/IP Ethernet 10/100BASE-T network, providing the single segment length from the network hub or switch to the terminal does not exceed 328 wire-feet. A typical topology for the Maximus terminal in an Ethernet 10/100BASE-T network is a star configuration. For Ethernet communication applications, we recommend using CAT-5 unshielded twisted-pair high-speed data transmission cable with RJ45 plugs wired according to the EIA/TIA 568B standard. One end of the RJ45-terminated cable plugs into the Maximus Ethernet communication port or PoE option card, while the other end plugs into the network hub. Figure 2-11 shows connecting a standard Ethernet cable into the Ethernet Port on the Maximus.

Figure 2-11

Connecting Standard Ethernet to the Maximus Terminal

RS232 Connection The Maximus options include an RS232 serial module with either an RJ11 or RJ45 socket. ATS recommends using its modular telephone type data cable. This eight conductor shielded flat cable has RJ45 modular plugs on each end. Terminate one end of the cable at the Maximus terminal’s serial option card and the other end at the host computer’s serial port through an ATS RS232 communication adapter. Be sure to follow all applicable electrical codes when installing the cable.

2-12

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 45

Chapter 2: Installation

Figure 2-12

Connections

Connecting an RS232 Serial Module

56k Modem Connection If your Maximus is equipped with a 56k Modem Module, plug one end of a standard RJ11 modular phone cable (customer-supplied) into the socket on the module (as shown in Figure 2-13) and the other end into an analog telephone socket. The modem does not support digital telephone lines.

Figure 2-13

MANU-MAXIMUS-02 Revision-02

Connecting a 56k Modem Module

Maximus Reference Manual

2-13

Page 46

Connections

Chapter 2: Installation

GSM Module SIM Card Installation If your Maximus is equipped with a GSM (Cellular) Module, install the SIM card (customersupplied) into the module as shown in Figure 2-14.

Figure 2-14

Installing a SIM Card in a GSM Module

GSM Long Cable Antenna The optional GSM/GPRS module comes with two antenna. One ships connected to the module and mounted to the outside of the Maximus outer case. A second antenna, equipped with a 5-meter cable (Part Number 17-7003-00), provides flexibility for locations with poor GSM signal reception. Figure 2-15 shows how to connect/install the 5-meter antenna. Use the following procedure to install the 5-meter antenna:

2-14

1.

Disconnect the factory installed antenna from the GSM/GPRS module.

2.

Route the 5-meter antenna into the Maximus terminal and connect it to the GSM/GPRS module as shown in Figure 2-15.

3.

Run the GSM Signal strength function in the Test Mode as described in "GSM Signal Strength" on page 3-57 (for a standard Maximus) or GSM Signal Strength on page 4-32 (for a Color Maximus).

4.

Move the antenna to the strongest signal strength and secure it by removing the protective paper on adhesive back on the antenna then attaching the antenna to a wall or other stationary structure.

5.

Exit the GSM Signal Strength function from Test Mode.

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 47

Chapter 2: Installation

Figure 2-15

Connections

Installing the 5-Meter Cable Antenna

DIDO Relay Module Connection The optional DIDO relay modules enable the terminal to control various external devices such as bells, horns, and doors. The modules provide a relay contact closure to activate electronic access entry, solenoids or buzzers. Two input connections provide contact monitoring. The Maximus supports three types of optional DIDO modules (5 total):

DANGER SHOCK

MANU-MAXIMUS-02 Revision-02

•

Solid State Relay DIDO Modules (120 VAC, 240VAC, 60VDC)

•

Single Form-C Relay (Mechanical, Dry Contact) DIDO Module

•

Dual Form-C Relay (Mechanical, Dry Contact) DIDO Module

We recommend that a qualified electrician perform relay wiring in accordance with local electrical regulations and best practices. The minimum size wire that can be used to wire to the relay board is 17 AWG. A 5-amp fuse on the relay board protects it from over-current conditions.

Maximus Reference Manual

2-15

Page 48

Connections

Chapter 2: Installation

Solid State DIDO Modules The DO functionality of the modules utilize either a 120 VAC / 2 amp, a 240 VAC / 1 amp, or a 60 VDC, 3 amp solid state relay. A five-position screw down connector serves as the gateway between the Relay Module peripheral controller and the external mechanism. The DI portion of the module is an input-sensing device. Utilizing opto-isolation circuitry the module accepts make/break contacts used as monitoring devices or as input status messages. Figure 2-16 provides a wiring diagram for the 120 and 240 VAC versions of the module:

Figure 2-16

120/240 VAC Solid State DIDO Wiring Diagram IN-

IN+

OUT-

OUT+

AC AC

Load Switch

Figure 2-17 provides a wiring diagram for the 60 VDC version of the module:

Figure 2-17

60 VDC Solid State DIDO Wiring Diagram IN-

IN+

OUT-

OUT+

Load

DC Load Power Supply

Switch

FORM-C DIDO Modules The DO functionality of the Form “C” Relay Module utilizes an AC (Alternating Current) up to two hundred forty (240) volt, one ampere, Form “C” relay or up to a 24 VDC / 2 amp, Form “C” relay. The DI portion of the module is an input-sensing device. Utilizing opto-isolation circuitry, the module accepts externally generated signal levels such as make/break contacts used as monitoring devices or as input status messages. Figure 2-18 provides a wiring diagram for the Form-C modules (shown wired for Normally Open operation):

Figure 2-18

Form-C DIDO Wiring Diagram IN-

IN+

COM

NO

NC

Load

Load Power Supply

Switch

2-16

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02