Page 33
Installation
2 Chapter
About this Chapter This chapter describes the Maximus installation and provides an overview of component and module locations.
Chapter Contents This chapter contains the following topics: Installation Guidelines ...................................................................................................... 2-3 Installation Choices ............................................................................................... 2-3 Wiring Distances ................................................................................................... 2-3 Terminal Wiring Access ......................................................................................... 2-5 Terminal Installation ......................................................................................................... 2-6 Opening and Separating the Case ......................................................................... 2-6 Mounting the Terminal .......................................................................................... 2-7 Main Components .............................................................................................. 2-10 Connections .................................................................................................................. 2-12 Standard Ethernet Connection ............................................................................ 2-12 RS232 Connection .............................................................................................. 2-12 56k Modem Connection ..................................................................................... 2-13 GSM Module ...................................................................................................... 2-14 DIDO Relay Module Connection .......................................................................... 2-15 Hand-Held CCD Scanner ..................................................................................... 2-18 WiFi External Antenna ........................................................................................ 2-18 Power Connection ......................................................................................................... 2-19 Power Pack ......................................................................................................... 2-19 Power over Ethernet ........................................................................................... 2-19 Connecting the UPS Battery ................................................................................ 2-20
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
2-1
Page 34
Chapter 2: Installation
This page intentionally left blank.
2-2
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 35
Chapter 2: Installation
Installation Guidelines
Installation Guidelines The standard Maximus is designed to operate indoors. Exposure to outdoor elements, such as rain or snow, voids the manufacturer warranty and may cause damage to the device. Select a location with adequate lighting (away from direct sunlight) and accessibility so employees can operate the terminal safely. The terminal should be mounted on a vibration-free surface. For more information about environmental requirements, see "Specifications" on page 1-5.
Installation Choices You must choose: •
How the host computer communicates with the terminal.
•
How to supply power to the terminal.
Wiring Distances The Maximus can communicate with a host computer in these ways: •
10/100 BASE-T Ethernet (standard)
•
RS232 (option)
•
Dial-up modem (option)
When you have chosen a communication method, run the required wiring from the host computer to the location selected for mounting the terminal. Sections below give more detail for each type of communication. Be sure the distance from the terminal’s location to the host computer does not exceed the wire length limitation of the connection type you plan to use. These limits are shown in Table 2-1.
Table 2-1
Wire Length Limitations Connection Type
Maximum Terminal-to-Host Distance
Ethernet 10/100BASE-T
328 wire-feet (100 meters) from terminal to Ethernet hub or switch
RS232
50 wire-feet Table 2-1
If you are using a modem connection, there must be an analog telephone jack available at the terminal’s location.
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
2-3
Page 36
Installation Guidelines
Figure 2-1
Chapter 2: Installation
Power Pack Location Requirements
Power Pack within 4-feet (122 cm) of terminal Mount 39 inches (99 cm) from the bottom of the Maximus base to the floor (recommended for ADA requirement)
2-4
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 37
Chapter 2: Installation
Installation Guidelines
Terminal Wiring Access The Maximus provides three access points for routing wires into the terminal: two Conduit Openings (holes) and a recessed channel that leads to the “opening to case interior” and accepts surface wiring (see Figure 2-2). In addition, the Maximus is equipped with a cable clamp that secures surface wiring routed through the recessed channel or fed through the lower conduit opening. Choose the wiring method best suited to your installation. Run required communication cabling (Ethernet, serial, or telephone line) to the location. If you have wiring for any optional devices such as DIDO, run those wires to the terminal location following all applicable electrical codes.
Figure 2-2
Wiring Access Locations (Rear View of Maximus)
Conduit Opening Opening to case interior Cable Clamp Recessed Channel Conduit Opening
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
2-5
Page 38
Terminal Installation
Chapter 2: Installation
Terminal Installation This section describes how to wall mount the Maximus terminal and provides the locations of the main components inside.
Opening and Separating the Case While not necessary, you may find it easier to install the mounting base on the wall if you separate the base from the terminal. Use the following procedure if you wish to separate the mounting base from the terminal:
Figure 2-3
1.
Unlock the terminal with the supplied key (see Figure 2-3 for the chassis lock location).
2.
Open the unit by pulling gently on the right-hand edge of the terminal, so it swings open on the hinges (the terminal is hinged to the base on the left edge as you face it).
3.
If there are any short jumper cables between the terminal and the base, unplug each jumper from the terminal, making a note of where each one goes so you can reconnect them.
4.
The terminal uses a fixed upper hinge-pin and a spring-loaded lower hinge-pin. Raise the spring-loaded lower pin until the terminal can pivot sideways enough to clear the lower pin support (see Figure 2-4).
5.
Then, slide the terminal upward to free the upper pin. When the terminal and base are separated, lay the terminal aside in a safe place.
Chassis Key Location
Chassis Lock & Key
2-6
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 39
Chapter 2: Installation
Figure 2-4
Terminal Installation
Separating the Terminal from the Base
SpringLoaded Pin
Mounting the Terminal When you have run the necessary communication wiring to the terminal location and arranged for a power source, you can mount the terminal on the wall. 1.
MANU-MAXIMUS-02 Revision-02
Choose a flat, smooth, interior wall for the terminal’s location. You will mount the Maximus using 4mm / #8 pan head screws in four places. Refer to Figure 2-2 on page 2-5 or use the mounting template (Part Number 06-1100-02) to mark the wall prior to any drilling. To meet ADA recommendations for forward reach, position the screw locations / template so the bottom of the mounting base is 39 inches (99cm) above the floor.
Maximus Reference Manual
2-7
Page 40
Terminal Installation
Figure 2-5
Chapter 2: Installation
Mounting Template Dimensions (Not to Scale) -1/4 in. -6.4 mm
0 in. 0 mm
2 in. 50.8 mm
4 in. 101.6 mm
0 in. 0 mm
1-9/16 in. 40.2 mm
6-5/8 in. 168.3 mm
Mount 39 inches (99 cm) from the bottom of the Maximus base to the floor (recommended for ADA requirement)
2-8
2.
Be sure all required wiring is present and any cable clamps properly installed. Follow any applicable wiring codes.
3.
Partially install the three upper screws.
4.
Lower the mounting base onto the three upper screws then tighten them (refer to Figure 2-6 on page 2-9 or Figure 2-7 on page 2-9 depending on if you separated the terminal or didn’t separate the terminal, respectively).
5.
Install the bottom screw and tighten until snug.
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02