Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 25

Maximus Reference Manual: Installation, pages 33 to 40

Pages 33 to 40 of 214, from Maximus Reference Manual

The original document is the PDF (18 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Ceridian MXS2100 and Accu-Time MXS2100

Page 33

Installation

2 Chapter

About this Chapter This chapter describes the Maximus installation and provides an overview of component and module locations.

Chapter Contents This chapter contains the following topics: Installation Guidelines ...................................................................................................... 2-3 Installation Choices ............................................................................................... 2-3 Wiring Distances ................................................................................................... 2-3 Terminal Wiring Access ......................................................................................... 2-5 Terminal Installation ......................................................................................................... 2-6 Opening and Separating the Case ......................................................................... 2-6 Mounting the Terminal .......................................................................................... 2-7 Main Components .............................................................................................. 2-10 Connections .................................................................................................................. 2-12 Standard Ethernet Connection ............................................................................ 2-12 RS232 Connection .............................................................................................. 2-12 56k Modem Connection ..................................................................................... 2-13 GSM Module ...................................................................................................... 2-14 DIDO Relay Module Connection .......................................................................... 2-15 Hand-Held CCD Scanner ..................................................................................... 2-18 WiFi External Antenna ........................................................................................ 2-18 Power Connection ......................................................................................................... 2-19 Power Pack ......................................................................................................... 2-19 Power over Ethernet ........................................................................................... 2-19 Connecting the UPS Battery ................................................................................ 2-20

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

2-1

Page 34

Chapter 2: Installation

This page intentionally left blank.

2-2

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 35

Chapter 2: Installation

Installation Guidelines

Installation Guidelines The standard Maximus is designed to operate indoors. Exposure to outdoor elements, such as rain or snow, voids the manufacturer warranty and may cause damage to the device. Select a location with adequate lighting (away from direct sunlight) and accessibility so employees can operate the terminal safely. The terminal should be mounted on a vibration-free surface. For more information about environmental requirements, see "Specifications" on page 1-5.

Installation Choices You must choose: •

How the host computer communicates with the terminal.

•

How to supply power to the terminal.

Wiring Distances The Maximus can communicate with a host computer in these ways: •

10/100 BASE-T Ethernet (standard)

•

RS232 (option)

•

Dial-up modem (option)

When you have chosen a communication method, run the required wiring from the host computer to the location selected for mounting the terminal. Sections below give more detail for each type of communication. Be sure the distance from the terminal’s location to the host computer does not exceed the wire length limitation of the connection type you plan to use. These limits are shown in Table 2-1.

Table 2-1

Wire Length Limitations Connection Type

Maximum Terminal-to-Host Distance

Ethernet 10/100BASE-T

328 wire-feet (100 meters) from terminal to Ethernet hub or switch

RS232

50 wire-feet Table 2-1

If you are using a modem connection, there must be an analog telephone jack available at the terminal’s location.

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

2-3

Page 36

Installation Guidelines

Figure 2-1

Chapter 2: Installation

Power Pack Location Requirements

Power Pack within 4-feet (122 cm) of terminal Mount 39 inches (99 cm) from the bottom of the Maximus base to the floor (recommended for ADA requirement)

2-4

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 37

Chapter 2: Installation

Installation Guidelines

Terminal Wiring Access The Maximus provides three access points for routing wires into the terminal: two Conduit Openings (holes) and a recessed channel that leads to the “opening to case interior” and accepts surface wiring (see Figure 2-2). In addition, the Maximus is equipped with a cable clamp that secures surface wiring routed through the recessed channel or fed through the lower conduit opening. Choose the wiring method best suited to your installation. Run required communication cabling (Ethernet, serial, or telephone line) to the location. If you have wiring for any optional devices such as DIDO, run those wires to the terminal location following all applicable electrical codes.

Figure 2-2

Wiring Access Locations (Rear View of Maximus)

Conduit Opening Opening to case interior Cable Clamp Recessed Channel Conduit Opening

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

2-5

Page 38

Terminal Installation

Chapter 2: Installation

Terminal Installation This section describes how to wall mount the Maximus terminal and provides the locations of the main components inside.

Opening and Separating the Case While not necessary, you may find it easier to install the mounting base on the wall if you separate the base from the terminal. Use the following procedure if you wish to separate the mounting base from the terminal:

Figure 2-3

1.

Unlock the terminal with the supplied key (see Figure 2-3 for the chassis lock location).

2.

Open the unit by pulling gently on the right-hand edge of the terminal, so it swings open on the hinges (the terminal is hinged to the base on the left edge as you face it).

3.

If there are any short jumper cables between the terminal and the base, unplug each jumper from the terminal, making a note of where each one goes so you can reconnect them.

4.

The terminal uses a fixed upper hinge-pin and a spring-loaded lower hinge-pin. Raise the spring-loaded lower pin until the terminal can pivot sideways enough to clear the lower pin support (see Figure 2-4).

5.

Then, slide the terminal upward to free the upper pin. When the terminal and base are separated, lay the terminal aside in a safe place.

Chassis Key Location

Chassis Lock & Key

2-6

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 39

Chapter 2: Installation

Figure 2-4

Terminal Installation

Separating the Terminal from the Base

SpringLoaded Pin

Mounting the Terminal When you have run the necessary communication wiring to the terminal location and arranged for a power source, you can mount the terminal on the wall. 1.

MANU-MAXIMUS-02 Revision-02

Choose a flat, smooth, interior wall for the terminal’s location. You will mount the Maximus using 4mm / #8 pan head screws in four places. Refer to Figure 2-2 on page 2-5 or use the mounting template (Part Number 06-1100-02) to mark the wall prior to any drilling. To meet ADA recommendations for forward reach, position the screw locations / template so the bottom of the mounting base is 39 inches (99cm) above the floor.

Maximus Reference Manual

2-7

Page 40

Terminal Installation

Figure 2-5

Chapter 2: Installation

Mounting Template Dimensions (Not to Scale) -1/4 in. -6.4 mm

0 in. 0 mm

2 in. 50.8 mm

4 in. 101.6 mm

0 in. 0 mm

1-9/16 in. 40.2 mm

6-5/8 in. 168.3 mm

Mount 39 inches (99 cm) from the bottom of the Maximus base to the floor (recommended for ADA requirement)

2-8

2.

Be sure all required wiring is present and any cable clamps properly installed. Follow any applicable wiring codes.

3.

Partially install the three upper screws.

4.

Lower the mounting base onto the three upper screws then tighten them (refer to Figure 2-6 on page 2-9 or Figure 2-7 on page 2-9 depending on if you separated the terminal or didn’t separate the terminal, respectively).

5.

Install the bottom screw and tighten until snug.

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02