Page 55
Monochrome Terminals
3 Chapter
About this Chapter This section tells you how to use the monochrome Maximus menus to set up your monochrome terminal. (See Chapter 4, "Color Terminals" to set up a color Maximus).
NOTE:
If you have a Accu-Engine Serial terminal configured for Java programming, see the Advanced Development Manual for Accu-Time Terminals for additional information.
Chapter Contents This chapter contains the following topics: Monochrome Display ....................................................................................................... 3-3 Power Up ........................................................................................................................ 3-4 Initial Setup ..................................................................................................................... 3-5 Initial Setup Menu Navigation ............................................................................... 3-5 Initial Setup Parameters ......................................................................................... 3-7 ATS TSD Mode ............................................................................................................... 3-13 Using the TSD Mode ........................................................................................... 3-14 ATS Setup Mode ............................................................................................................ 3-15 Setup Mode Parameters ...................................................................................... 3-16 Re-Boot .............................................................................................................. 3-16 Setup Password .................................................................................................. 3-17 Setup Host Connect ............................................................................................ 3-18 Setup Smartcard ................................................................................................. 3-27 Setup Comm Port ............................................................................................... 3-28 Device Setup ....................................................................................................... 3-29 Setup WiFi .......................................................................................................... 3-30 Delete FP Templates ............................................................................................ 3-35 Reset Dnld .......................................................................................................... 3-37 Download from USB ........................................................................................... 3-38
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
3-1
Page 56
Chapter 3: Monochrome Terminals
Date/Time Setup ............................................................................................................ 3-39 Information Mode .......................................................................................................... 3-41 Version Info ......................................................................................................... 3-42 Memory Info ....................................................................................................... 3-43 Misc Info ............................................................................................................. 3-44 Ethernet Info ....................................................................................................... 3-44 Information Mode .......................................................................................................... 3-41 Test Mode ...................................................................................................................... 3-46 Accessing Test Mode ........................................................................................... 3-46 Reader Test ......................................................................................................... 3-47 Exit ..................................................................................................................... 3-47 System Diag Dump .............................................................................................. 3-48 Smart Card Test ................................................................................................... 3-49 Serial Test: Direct ................................................................................................. 3-50 Serial Test: Printer ................................................................................................ 3-51 LED Test .............................................................................................................. 3-51 Display Test ......................................................................................................... 3-52 Speaker/Beep Test ............................................................................................... 3-52 System Test ......................................................................................................... 3-53 USB Test .............................................................................................................. 3-54 Battery/Charger Test ............................................................................................ 3-54 Modem Test ........................................................................................................ 3-56 RTC Test .............................................................................................................. 3-57 DIDO Test 1 ......................................................................................................... 3-58 Keypad Test ......................................................................................................... 3-59 Biometric Test ...................................................................................................... 3-60
3-2
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 57
Chapter 3: Monochrome Terminals
Monochrome Display
Monochrome Display While the power and physical characteristics of a monochrome and color Maximus are the same, their setup menus are different. You can differentiate between the monochrome and color Maximus without turning on the terminal. The monochrome Maximus lens has a much smaller window/LCD display than the color lens. Figure 3-1 shows the color Maximus lens (see Figure 4-1 on page 4-3 for an illustration of the color lens).
Figure 3-1
MANU-MAXIMUS-02 Revision-02
Monochrome Maximus Lens
Maximus Reference Manual
3-3
Page 58
Power Up
Chapter 3: Monochrome Terminals
Power Up If the terminal does not have an application saved the message Download Needed appears at power-up or after a re-boot showing that the terminal is ready to accept (needs) a program download from the host.
Download Needed PGM: nnnn-nnn-nnn The numeric value after the Program prompt (PGM:), nnnn-nnn-nnn, shows the terminal type, Universal Command Set (UCS) Version, and the no-longer applicable number of boards (N/A) in the terminal as follows:
PGM: nnnn-nnn-nnn Terminal Type
UCS Version
N/A
Table 3-1 lists the terminal type codes and the corresponding terminal descriptions. Table 3-1
Terminal Type Codes Code
Terminal Type Description
6100
Maximus, non-Java, UCS
6101
Maximus Java
6103
Maximus Python (Mono)
6150
Color Maximus, non-Java, UCS
6151
Color Maximus, Java, UCS
6155
Color Maximus, UCS with XML
6160
Maximus NEMA, mono, UCS
6161
Maximus NEMA, mono, Java
6163
Maximus NEMA, mono, Python Table 3-1
3-4
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 59
Chapter 3: Monochrome Terminals
Initial Setup
Initial Setup To enter configuration mode, press and hold both the clear and enter keys simultaneously for about five seconds. If the terminal prompts you to enter a password, type in the password using the numeric keys then press the enter key. The Initial Setup parameters appear starting with Setup Host IP.
NOTE:
At any point in the configuration menus you can press and hold both the clear and enter keys simultaneously to return to the start of the "Initial Setup Parameters" on page 3-7.
Initial Setup Menu Navigation The terminal will display the saved or default values for the terminal IP connectivity options. In general, press the enter key to accept the displayed value and go to the next option or press the clear key to change the value.
NOTE:
If you type an invalid IP, subnet mask, or other value, the terminal reports the error and returns to the previous value (the default value or the previously saved value).
Figure 3-2 provides a flow-chart of the Initial Setup Menu structure.
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
3-5
Page 60
Initial Setup
Figure 3-2
Chapter 3: Monochrome Terminals
Initial Setup Menu Structure Flow Chart Download Needed PGM: nnnn-nnn-nnn enter/clear (hold) Setup Host IP nnn.nnn.nnn.nnn enter Setup Socket Port Socket Port: 2500 enter Setup Addressing Type: Dynamic DHCP clear enter
Setup Addressing Type: Static IP enter Setup Clock IP 000.000.000.000 enter Setup Router IP nnn.nnn.nnn.nnn enter Setup DNS IP 000.000.000.000 enter Setup the SubMask 255.255.255.000 enter DHCP Option Code 0 enter Terminal Name: ATS000001 enter Append TCP Data with EOT: No
ATS TSD Mode Setup Mode enter enter ATS Setup Mode Re-Boot
3-6 clear
Maximus Reference Manual
ATS Setup Mode Setup Password
MANU-MAXIMUS-02 Revision-02
Page 61
Chapter 3: Monochrome Terminals
Initial Setup
Initial Setup Parameters To enter the initial setup menu press the clear and enter keys simultaneously for 5-seconds (maximum). Enter a password if prompted. 1.
The terminal displays the default (192.168.001.100) or saved value for the Host that provides communications to the terminal.
Setup Host IP nnn.nnn.nnn.nnn Press the enter key to accept the displayed IP address and continue to the next parameter or press the clear key to change the host IP address. If you pressed the clear key use the numeric keys to type in the IP address of the host then press the enter key to save the new IP address. If you type an invalid IP address, the terminal displays Bad IP Address and returns you to the saved/default value. Press the clear key again to correct the address then press the enter key to save it. 2.
Next the terminal displays the default/saved socket port number used by the terminal. The default value is 2500. Press the enter key to accept the displayed port number or press the clear key to change it using the numeric keys. When finished press the enter key to save the socket port number and continue to the next parameter.
Setup Socket Port Socket Port: 2500 If you type an invalid socket port number the terminal displays Invalid Socket Port. and returns you to the saved/default value. Press the clear key again to correct the port number then press the enter key to save it.
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
3-7
Page 62
Initial Setup
Chapter 3: Monochrome Terminals
3.
Next the terminal displays the default/saved addressing mode for the terminal. The default value is Dynamic DHCP. In DHCP mode the terminal receives its IP address from the connected DHCP server (therefore the terminal IP address may periodically change).
Setup Addressing Type: Dynamic DHCP Press the enter key to accept DHCP mode and continue or press the clear key to toggle the display between the Static IP and Dynamic DHCP selections. If the terminal was already in the displayed mode (Dynamic DHCP or Static IP) and you pressed the enter key without changing it, the terminal enters the ATS TSD Mode. Proceed to "ATS TSD Mode" on page 3-13).
4.
•
The Static IP selection enables you to set the terminal to a permanent IP address.
•
When the terminal displays the desired option (Dynamic DHCP or Static IP) press the enter key to save the selection and continue to the next parameter.
•
If you changed to the Static IP option the terminal displays the static IP addressing parameters starting with Setup Clock IP.
•
If the terminal is set to Static IP (and rebooted) the terminal displays Static IP for the Type. You can access the static IP parameters by pressing the clear key, toggling the Static IP and Dynamic DHCP options and re-saving the Static IP option.
The Setup Clock IP parameter enables you to change the static IP address for the terminal. Press the clear key then use the numeric keys to change the terminal IP address. Press the enter key to save the new address and continue.
Setup Clock IP 000.000.000.000 If you type an invalid IP address, the terminal displays Bad IP Address. Press the clear key again, correct the IP address then press the enter key to continue.
3-8
Maximus Reference Manual
MANU-MAXIMUS-02 Revision-02
Page 63
Chapter 3: Monochrome Terminals
5.
Initial Setup
Next the terminal displays the Setup Router IP (Gateway IP address) parameter. Press the enter key to accept the displayed address or press the clear key then use the numeric keys to change the address. Press the enter key to save the new Gateway IP address when finished.
Setup Router IP nnn.nnn.nnn.nnn If you type an invalid IP address, the terminal displays Bad IP Address. Press the clear key again, correct the IP address then press the enter key to continue. 6.
Next the terminal displays the Setup DNS IP parameter.
Setup DNS IP 000.000.000.000 Press the enter key to accept the displayed IP address for the DNS (Domain Name System) server or press the clear key then use the numeric keys to change the address. Press the enter key to save the new address and continue. If you type an invalid IP address, the terminal displays Bad IP Address. Press the clear key again, correct the IP address then press the enter key to continue.
MANU-MAXIMUS-02 Revision-02
Maximus Reference Manual
3-9