Page 144

Setup Mode

Figure 4-23

Chapter 4: Color Terminals

Secondary TCP/IP Setup Screen, Static Mode Host IP Address

Clock IP Address

Router IP Address

03:38:15 Friday Nov 7, 2014 Host XXX.XXX.XXX.XXX Clk XXX:XXX:XXX:XXX Rtr XXX.XXX.XXX.XXX DNS XXX.XXX.XXX.XXX

Return To TCP/IP

IP Address SubMask

Terminal Name

DNS Server IP

Exit Setup

Use the following procedure to change the Static IP settings (if desired):

4-28

1.

To change the Host IP address press the “F1” key to select the Host IP Address parameter and access the Enter the Host TCP/IP Address prompt screen. Use the numeric keys to type in the desired IP address then press the enter key to return to the Secondary TCP/IP Setup screen (You can press the “clear” key to delete a number).

2.

To change the Maximus terminal (clock) IP address press the “F2” key to select the Clock IP Address parameter and to access the Enter the Clock TCP/IP Address prompt screen. Use the numeric keys to type in the desired IP address then press the enter key to return to the Secondary TCP/IP Setup screen (You can press the “clear” key to delete a number).

3.

To change the IP address for the Gateway (router) press the “F3” key to select the Router IP Address parameter and to access the Enter the Router TCP/IP Address prompt screen. Use the numeric keys to type in the desired IP address then press the enter key to return to the Secondary TCP/IP Setup screen (You can press the “clear” key to delete a number).

4.

To change the Maximus terminal (clock) subnet mask (SubMask) press the “F5” key to select the IP Address SubMask parameter and access the Enter the SubMask prompt screen. Use the numeric keys to type in the desired subnet mask then press the enter key to return to the Secondary TCP/IP Setup screen (You can press the “clear” key to delete a number).

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 145

Chapter 4: Color Terminals

Setup Mode

5.

To change the name for the Maximus terminal, press the “F6” key to select the Terminal Name parameter and access the Enter the Terminal Name prompt screen. The Terminal Name parameter enables you to set a unique up-to-20 character administrative name for the terminal. The default name is “ATS” plus the last 6-digits of the terminal MAC address (e.g., ATS000001).

NOTE:

Applications such as Accu-Engine require “ATS” as the first three characters of the Terminal Name. If not, Accu-Engine will only display the terminal IP address (that can change with DHCP enabled).

NOTE:

Firmware Versions prior to 2.05.11(X) do not save any changes to the Terminal Name. If you make any changes the terminal reverts to the default Terminal Name after a re-boot.

Common Settings for Dynamic and Static IP Modes •

MANU-MAXIMUS-02 Revision-02

Return to Setup – This function appears in different menus and returns the terminal to the previous menu screen. For example, press the “F4” key when in the TCP/IP WiFi setup screen to return to the Host Type Ethernet menu screen or press the “F8” key when in the Comm Post setup menu to return to the Host Type configuration screen.

Maximus Reference Manual

4-29

Page 146

Test Mode

Chapter 4: Color Terminals

Test Mode To enter Test Mode, press the “F7” key to select Test, Setup, Diagnostics from the main Configuration Menu screen (shown in Figure 4-24) and enter the Test, Setup Diagnostics menu screen as shown in Figure 4-25.

Figure 4-24

Color Maximus Configuration Menu (Initial Setup Menu Shown) Host IP Address

Static IP

IP Address

03:12:18 Friday Nov 7, 2014 Host XXX.XXX.XXX.XXX Clk XXX.XXX.XXX.XXX Rtr XXX.XXX.XXX.XXX Mask XXX.XXX.XXX.XXX

Re-Boot

Figure 4-25

Set Date & Time

Reset Download & FP Device

Test, Setup, Diagnostics

Exit

Test Setup Diagnostics Screen Setup Mode

Test Mode

10:19 AM

Restore Factory Settings

Thursday Nov 13, 2014

Information Mode

Download from USB

4-30

Exit

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 147

Chapter 4: Color Terminals

Test Mode

Press the “F2”Function key to enter Test Mode and display the Test Mode screen as shown in Figure 4-26.

Figure 4-26

Test Mode

03:38:15 Friday Nov 7, 2014 Test Mode Test Name Prev

Next

NOTE:

To exit Test Mode, cycle through the test selections until the Exit option appears, then press the enter key. •

Use the Next function (“F8” key) to cycle through the tests.

•

Use the Prev function (“F7” key) to cycle through the tests in the reverse order.

•

Press the enter key to start the currently displayed test.

You can select the tests in the following sections (some require optional hardware and configuration to activate the test in the menu).

Reader Test This test enables you to test a card reader or wand. Press the enter key when the display reads “Test Mode Reader Test” to start the test. When the display reads “Test Reader or Wand” use a card (e.g., swipe) or activate the wand. Press the clear key or select Next to exit the test when finished.

Biometric Test Press the enter key when the display reads “Test Mode Biometric Test” to start the test. The display changes to read “Test Finger Print Press Enter to start”. Press the enter key and follow the directions on the screen (steps through an enrollment test followed by a verification test). If the test fails, you can press the enter key to reselect the Biometric Test. Press the clear key or select either Next or Prev to exit the test when finished.

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

4-31

Page 148

Test Mode

Chapter 4: Color Terminals

Keypad Test This tests each numeric and function key on the terminal. If you press an incorrect key the system will beep and the red LED (X) flashes. When you successfully complete the test the system exits to the next test. You can press the clear key to exit before completing the test. Press the enter key when the display reads “Test Mode Keypad Test” to start the test then: •

Press the numbers 1–9 then 0 in order.

•

Press the function buttons, starting at the top on the left in order down to the bottom on the left (“F1” to “F4”), then the top on the right down to the bottom on the right (“F5 to “F8”). These display as A through H.

DIDO Test 1 Press the enter key when the display reads “Test Mode DIDO Test 1” to start the test. The test runs then displays the result. Press the clear key to exit the test before it finishes. •

DIDO Test 2 – Press the enter key when the display reads “Test Mode DIDO Test 2” to start the test. Press the clear key to exit the test before it finishes.

GSM Signal Strength This option only appears with a GSM / GPRS module installed and used primarily when installing a 5-meter antenna (see "GSM Long Cable Antenna" on page 2-14). Press the enter key when the display reads “Test Mode GSM Signal Strength” to start the test. The test displays the signal strength of the cellular data network received by the GSM antenna. Move the terminal, antenna, or both to change the received signal strength. You need a signal strength of at least 15 for a GSM/GPRS module. Press the clear key to exit when finished.

NOTE:

Signal strength measures from 0 to 32 with 15 or higher being best.

RTC Test Press the enter key when the display reads “Test Mode RTC Test” to start the test. This tests the real-time clock (HW and SW) and beeps every second. Press the clear key to exit the test when finished.

Battery/Charger Test Press the enter key when the display reads “Test Mode Battery/Charger Test” to enter the test and display the “Battery/Charger Test Press Enter to Test” prompt. Press the enter key to test the components of the optional backup battery and proceed to the next test. The status of each component displays on the screen each time you press the enter key. The tests are for the UPS (Present or not), Battery (OK or Not OK), and AC (Present or not). Press the clear key to exit when finished

USB Test Press the enter key when the display reads “Test Mode USB Test” to enter the test and display the “USB Storage Test Attach drv, tap Enter” prompt. Open the terminal and install a USB flash drive into the USB port then press the enter key. The results appear on the screen when the test completes (e.g., Passed). Remove the USB flash drive and press the clear key to exit.

4-32

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 149

Chapter 4: Color Terminals

Test Mode

System Test This does a quick check on the integrity of the RAM, FLASH, and EEPROM installed on the terminal. Press the enter key when the display reads “Test Mode System Test” to enter the test and display the “System Test Press Enter to Test” prompt. The results of the test appear on the screen when the test completes, including notification of any failures. Press the enter key when the system displays “Enter to continue” to exit the test.

Speaker/Beep Test Press the enter key when the display reads “Test Mode Speaker/Beep Test” to start the test. The terminal initiates three increasing frequency beeps to verify that the speaker works correctly. Press the clear key or select either Prev or Next to exit the test.

Display Test Press the enter key when the display reads “Test Mode Display Test” to start the test. The display turns all the pixels off then on. Press the clear key or select either Prev or Next when finished.

LED Test Press the enter key when the display reads “Test Mode LED Test” to start the test. This lights all the LEDs on the terminal one at a time, including those behind the lens and those on the keypad. Press the clear key or select either Prev or Next when finished.

Serial Test: Printer This test is a loopback and reserved for service personnel. It tests the auxiliary port and requires a specific hardware jumper.

Serial Test: Direct This test is a loopback and reserved for service personnel. It tests the serial port and requires a specific hardware jumper.

System Diag Dump This is a test done under the direction of a service technician to help troubleshoot the terminal. This test saves the results of your tests to a text file on a USB flash drive installed in the Maximus USB port. Press the enter key when the display reads “Test Mode System Diag Dump” to start. When the system displays the “Attach USB Drive then press Enter” prompt, open the Maximus cover and insert a USB flash drive into the USB port then press the enter key. The system displays “Results copied to USB” when complete. You can review the results with the technician by opening the text file (on a PC). Press the clear key or select either Prev or Next when finished.

Exit Press the enter key when the display reads “Test Mode Exit” to exit to the Test, Setup, Diagnostics menu (see "Test, Setup, Diagnostics (TSD) Menu" on page 4-13).

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

4-33

Page 150

Information Mode

Chapter 4: Color Terminals

Information Mode To enter Information Mode, select Information Mode (“F3” key) from the Test, Setup, Diagnostics menu (see "Test, Setup, Diagnostics (TSD) Menu" on page 4-13). To navigate Information Mode: •

Use the Next function (“F8” key) to cycle through the tests.

•

Use the Prev function (“F7” key) to cycle through the tests in the reverse order.

•

Press the enter key to view the currently displayed information settings/status.

•

Use the “up/down” functions (“F7” key and “F8” key) to scroll through the items (if the list is longer than the number of lines on the display).

•

Press the clear key to return to the Information Mode selections.

To exit Information Mode and return to the Test, Setup, Diagnostics menu, cycle through the selections to the Exit selection, then press the enter key.

Figure 4-27

Information Mode Screen

03:38:15 Friday Nov 7, 2014 Information Mode XXXXXXX Prev

Next

You can select and view the following information categories: •

4-34

Version Info – Press the enter key when the display reads “Information Mode Version Info” to view hardware, firmware, and software version information. Depending on the Maximus configuration the information can include: •

U-Boot (boot-loader version information)

•

U-Boot (date of the boot-loader version)

•

Kernel (main operating system version)

•

Kernel (main operating system version date)

•

Eeprom (hardware driver version)

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 151

Chapter 4: Color Terminals

Information Mode

•

•

•

MANU-MAXIMUS-02 Revision-02

•

Eeprom (hardware driver version date)

•

Speaker (speaker driver version)

•

Speaker (speaker driver version date)

•

AtsLeds (LED driver version)

•

AtsLeds (LED driver version date)

•

BarRdr (barcode reader driver version)

•

BarRdr (barcode reader driver version date)

•

Keypad (keypad driver version)

•

Keypad (keypad driver version date)

•

UCS (Universal Command Set software version)

•

UCS (Universal Command Set software version date)

• glibc (C library version for customization)

• glibc (C library branch information)

•

Java (version found – on Java systems, reports the date of the latest component of the java library)

•

Biometric (device found – provides information about any connected fingerprint reader

•

Smartcard (provides information about any connected smartcard)

Ethernet Info – Press the enter key when the display reads “Information Mode Ethernet Info” to view the following network information: •

Host IP (IP address of the host computer that the terminal connects to)

•

Local IP (IP address of the terminal)

•

Subnet Mask (IP subnet mask used by the terminal)

•

Gateway IP (IP address of the gateway/router)

•

DHCP OptionCode (DHCP option code, e.g., 0 for pad, set by protocol)

•

Mac Address (Media Access Control address of the terminal)

•

PHY (Ethernet controller type, e.g., Micrel KS8721 PHY)

Misc Info – press ENTER to view the following miscellaneous information: •

Serial Number (the terminal serial number)

•

Customer Number (customer number as noted at the ATS factory)

•

G-10 Number (PC board assembly number)

•

CPU (terminal CPU type and version)

Memory Info – Press the enter key when the display reads “Information Mode Memory Info” to view the following memory information: •

RAM Total (the total Random Access Memory installed on the terminal)

•

RAM Free (the amount of RAM available/unused on the terminal)

•

Flash Total (the total flash memory installed on the terminal)

•

Flash Free (the amount of flash memory available/unused on the terminal)

Maximus Reference Manual

4-35

Page 152

Setting Up the Screensaver

Chapter 4: Color Terminals

Setting Up the Screensaver The Color Maximus terminal features an automatic screen saver that is disabled by default. The screen saver is designed to protect the terminal screen from burn-in during periods of inactivity. After a preset period of time, the screen dims (becomes gray), and then the time and optionally an image display and move around the terminal’s screen. The screen saver is only controlled through a configuration file installed on the terminal: /etc/ssaver.conf. You can use this to set the time to idle, sleep, roving duration, and 12/24 hour mode, and the location of the logo. Open the ssaver.conf file in a text editor to view and change it. Screen saver images must be ASCII raster files and stored in a specific location on the terminal. Use the ZZDLOAD UCS command (see the UCS Reference Guide) or system-level commands to add and remove these graphics files. The logo must be a Windows bitmap (.BMP) file that is 250 pixels wide and 150 pixels high, or smaller. The BMP must be saved as an 8-bit color palette but a maximum of 224 colors can be used. (Some colors in the map are reserved for drawing the time digits, which use 32 shades of gray.) The ssaver.conf file has the following settings:

NOTE:

4-36

• idletime – Sets the number of seconds before idle mode activates after the last time the terminal was used. Set this to 0 to disable idle mode. In idle mode, the terminal’s display dims, but touch screen and key presses and badge swipes are processed immediately. The default is 45 seconds.

• sleeptime – Sets the number of seconds after idle mode activates that sleep mode activates. Set this to 0 to disable sleep mode. In sleep mode, the terminal’s display turns black and displays a clock. To use the terminal, press a key (or a touch screen, if applicable) to take the terminal out of sleep mode, and then enter your keypad transactions. Unlike key presses, badge transactions are processed immediately in sleep mode. The default is 45 seconds.

Set both idletime and sleeptime to 0 to turn off the screen saver.

• rovetime – Rovetime sets how quickly the displayed moves around the terminal screen when the terminal is in sleep mode. The default is 25 seconds.

• mode – Sets the display mode of the terminal. Set this to 12 to display a 12hour clock with an am or pm suffix. Set this to 24 to display a 24-hour clock. By default or if an invalid entry is made, the clock displays in 12-hour format.

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02