Maximus Reference Manual: Maintenance

Pages 153 to 164 of 214, from Maximus Reference Manual

The original document is the PDF (18 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Ceridian MXS2100 and Accu-Time MXS2100

Page 153

Maintenance

5 Chapter

About this Chapter This section tells you about power, maintenance, and troubleshooting for your Maximus terminal.

NOTE:

If you have a Accu-Engine Serial terminal configured for Java programming, see the Advanced Development Manual for Accu-Time Terminals for additional information.

Chapter Contents This chapter contains the following topics: Verifying Installation ........................................................................................................ 5-3 Test Download File ................................................................................................ 5-3 Maintenance ................................................................................................................... 5-4 Cleaning the Terminal ........................................................................................... 5-4 Cleaning the Badge Reader ................................................................................... 5-4 Cleaning the Biometric Sensor .............................................................................. 5-5 Caring for the Biometric Sensor ............................................................................ 5-7 Troubleshooting Guide ..................................................................................................... 5-8 Power-Related Troubleshooting ........................................................................... 5-10 Communication-Related Troubleshooting ............................................................ 5-10

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

5-1

Page 154

Chapter 5: Maintenance

This page intentionally left blank.

5-2

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 155

Chapter 5: Maintenance

Verifying Installation

Verifying Installation This section tells you how to verify that the installation is correct by performing a query and answerback sequence between a Maximus terminal and its host. Accu-Time Systems, Inc., has two sample host applications available: Accu-Engine and AccuEngineer. Your ATS representative can provide a copy. Use these to send a program download file to a terminal and monitor the terminal’s response.

Test Download File Use a text editor capable of inserting control characters (000 through 03110, 000 through 1716) to create a download file containing the lines. The following commands set the terminal offline, reset the terminal, specify a message to display, terminate the download, and put the terminal online. Figure 5-1 shows a sample download file.

Figure 5-1

Sample Download Test File

The » symbol represents a record separator character, 3010 or 1E16. For more information about control character symbols, see "Control Character Representation" on page P-4. Use Accu-Engine to send that download file to the terminal. The terminal should respond with a beep and display the text.

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

5-3

Page 156

Maintenance

Chapter 5: Maintenance

Maintenance The Maximus is a low-maintenance data collection terminal. The only required procedure is periodic cleaning of the badge reader, finger sensor, or other input device.

Cleaning the Terminal To clean a terminal’s exterior, moisten a cleaning cloth with a commercial or domestic hardsurface cleaner and wipe the terminal exterior to clean it. Since dried residue of cleaning product could become a future problem for the terminal’s electrical and mechanical connections, avoid gross application of cleaning product and do not spray cleaning product directly onto the terminal. These instructions do not apply to the interior of the terminal. See the following instructions for cleaning badge and fingerprint readers.

Cleaning the Badge Reader To clean the badge reader, swipe a cleaning card premoistened with isopropyl alcohol (rubbing alcohol) through the reader several times. Low-usage readers should be cleaned monthly. High-usage readers should be cleaned weekly. Although the finger sensors used in ATS terminals have few maintenance and handling requirements, a few basic precautions help ensure a high level of performance over the life of the sensor. Deposits from fingers accumulate on the surface of the finger sensor after repeated use. These deposits may be from natural oils from the finger or from dirt, grease, or lotions. These deposits may effect sensor operation, so you should clean the sensor as required by your environment. In normal use, we recommend cleaning the sensor once a month, or any time a residue is visible on the sensor surface or when the reader performance degrades.

5-4

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 157

Chapter 5: Maintenance

Maintenance

Cleaning the Biometric Sensor Use the following procedure to clean the Biometric sensor surface (all sensor technologies):

Caution

1.

Remove electrical power from the finger sensor by disconnecting the terminal from its power source.

2.

Use an alcohol prep wipe or dampen (not soaking or dripping wet) a clean cotton swab, a clean cotton ball, or a non-abrasive cloth with isopropyl alcohol.

Do not directly spray the sensor. Do not use nylon brushes or scouring pads, abrasive cleaning fluids or powders, or steel wool. These items can damage the sensor. Do not use bleach or chlorine-based cleaners, non-chlorine bleach, or chlorinebased bathroom or mildew cleaners. Chlorine-based cleaners do not necessarily affect the functionality of the fingerprint sensor, but they can discolor and could damage the surrounding enclosure and peripheral components. Do not use any solvents such as acetone, MEK, TCE, paint thinner, turpentine, etc. Do not allow cleaner to drip or run down into the enclosure.

MANU-MAXIMUS-02 Revision-02

3.

Gently rub the sensor surface and surrounding bezel with the damp cotton swab, rotating the swab to keep exposing a clean surface to the sensor.

4.

If the sensor is very dirty, you may need to repeat the cleaning operation using a new clean swab.

5.

After cleaning with the damp swab, gently rub the surfaces again with a clean dry cotton swab.

6.

Reconnect the terminal power when cleaning is complete.

Maximus Reference Manual

5-5

Page 158

Maintenance

Chapter 5: Maintenance

Cleaning an E-Field Conductive Ring (Bioscrypt) After an extended period of use, the conductive ring, surrounding the sensor, may become tarnished or accumulate deposits that can degrade performance (see "E-Field Sensor (Bioscrypt)" on page A-9 for how the conductive ring operates with the sensor).

Figure-6

Bioscrypt E-Field Sensor Conductive Ring Sensor Surface

Conductive Ring

Use the following procedure to clean the E-Field conductive ring:

Caution

5-6

1.

Remove electrical power from the finger sensor by disconnecting the terminal from its power source.

2.

Using a new pink rubber pencil eraser, remove the deposits/tarnishing from the surface of the conductive ring - do not use the eraser on the sensor surface.

3.

Use compressed air to remove the eraser dust from the reader. Alternately you can remove the eraser dust with a clean dry cotton ball.

4.

Clean the sensor surface using the procedure described in "Cleaning the Biometric Sensor" on page 5-5.

5.

Reconnect the terminal power when cleaning is complete.

Do not remove eraser dust with wet or damp material. Do not scratch the sensor surface. Do not rub the sensor surface with the eraser. Do not use an eraser to clean the sensor.

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 159

Chapter 5: Maintenance

Maintenance

Caring for the Biometric Sensor The sensor is designed to perform well even under harsh conditions. Nevertheless, some precautions should be taken to avoid damaging the sensor: •

MANU-MAXIMUS-02 Revision-02

Do not place the finger sensor close to a heat source, such as a radiator or hot plate. •

In addition, the sensor should not be exposed to rain or excessive moisture.

•

With the exception of the procedure as described in "Cleaning the Biometric Sensor" on page 5-5, do not put any liquids on the sensor. Never spray or pour liquids directly on the sensor.

•

Do not subject the finger sensor to heavy shocks or vibrations.

•

Do not allow the sensor to come in contact with metallic objects.

•

Periodically clean the sensor as described in "Cleaning the Biometric Sensor" on page 5-5 as appropriate for your specific site (different sites may require different cleaning schedules).

Maximus Reference Manual

5-7

Page 160

Troubleshooting Guide

Chapter 5: Maintenance

Troubleshooting Guide CAUTION

The terminal has no user-serviceable parts. Accu-Time terminals must be operated within the parameters described in this document. Any operation performed contrary to these parameters voids the warranty.

Table 6-1

Troubleshooting Diagnostic Table

Symptom

Possible Cause

Solution

Terminal does not power up, the display and none of the status LEDs are lit.

No DC power applied.

Ensure primary side of DC power pack assembly is plugged into a live AC outlet. Ensure secondary side of DC power pack assembly is plugged into the Time and Data Collection Terminal (DCT). Test the outlet by plugging in another appliance. If all else fails, replace the power pack assembly.

Terminal is not communicating with host computer.

Terminal does not accept badge data.

Terminal to Host communication cable is defective or unplugged on either end.

Verify cable is tested and plugged into both ends. Ensure that cable termination guidelines and lengths are observed.

Bar code badge is not manufactured to the proper specification.

See the vendor’s specifications for manufacturing criteria.

Badge is being swiped in the wrong direction.

Ensure media faces the correct direction: turn the card around and try again.

Ensure the application package is loaded and running on the host.

Badge code format is not supported.

Ensure badge code is among those supported. Supported codes include most standard bar code formats including UPCA, 128, 3 of 9, Interleave 2 of 5 and more, as well as IATA Track I and ABA Track II magnetic stripe input (reader dependent).

Badge reader needs cleaning.

Swipe a pre-moistened (isopropyl alcohol) cleaning card through the reader several times.

Badge number does not exist in validation file.

See a supervisor.

Table 6-1 (page 1 of 2)

5-8

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 161

Chapter 5: Maintenance

Table 6-1

Troubleshooting Guide

Troubleshooting Diagnostic Table

Symptom

Possible Cause

Terminal does not accept keypad input.

Keyed data does not exist in validation file Keypad connector is unplugged.

Solution See a supervisor Test the keypad in Test Mode (for monochrome terminals, see "Test Mode" on page 3-46, and for color terminals, see “Test Mode” on page 430).

Table 6-1 (page 2 of 2) If the suggested solutions have been tried and the problem still exists, contact the Accu-Time Systems Product Service Department at (860) 870-5000 during normal business hours: 9 am to 5 pm Eastern time, Monday through Friday. Before contacting Accu-Time, please be prepared to provide the serial number and the configuration number of the product.

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

5-9

Page 162

Troubleshooting Guide

Chapter 5: Maintenance

Power-Related Troubleshooting

Table 6-2 Symptom

Possible Cause

Solution

The terminal display is blank.

The primary of the power pack assembly is not plugged into an ACwall outlet, is not plugged into the terminal, or is the wrong voltage.

Check the outlet, both power pack connections, and that it is a 12 VDC power pack.

Outlet or power pack problem.

Check the outlet, both power pack connections, and that it is a 12 VDC power pack.

The low power (yellow) indicator LED is lit.

Replace the power pack.

Replace the power pack.

NOTE:

If the battery backup option is installed, the terminal operates for approximately 1.5 hours after the primary voltage source is lost. After this, the terminal turns off. When the terminal is in battery backup mode, the yellow low-power indicator LED is lit. before the terminal display goes blank.

Communication-Related Troubleshooting

5-10

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 163

Chapter 5: Maintenance

Troubleshooting Guide

Table 6-3 Symptom

Possible Cause

Solution

The terminal is not communicating with the host.

Communication parameters were not previously set.

Use Setup Mode to setup the terminal (for monochrome terminals, see "ATS Setup Mode" on page 3-15, and for color terminals, see "Setup Mode" on page 4-15). Your network administrator needs to provide the following: IP address to be assigned to the terminal IP address of the host to which the terminal can connect Network Mask (example 255.255.255.0) Port number (try 2500 by default) Gateway or router address (if required) Reboot the terminal to see if it connects. If parameters are set, ping the terminal. Verify that the cable is plugged into both ends (terminal and hub) and terminated to the appropriate eight-position modular connector. Verify that the single segment cable length is equal or less than 100 meters (328 feet). The cable should also be a 10/ 100BASE-T category 5, twisted pair high-speed data transmission cable with both ends properly crimped. Ensure application package is loaded and running on the host. Check the Ethernet diagnostic LEDs: BUSY: This amber or yellow light indicates the terminal is busy processing. LINK: This green light indicates the terminal is receiving network traffic, though the traffic might not be from the host.

A previously working terminal is not operational.

Cables not plugged in or host application software not operational.

Ensure that all connections are made and that the host software application is functional. If possible, take a known working terminal and readdress it for this particular node to determine whether the problem is related to the terminal, installation, or host.

If neither the standard nor Ethernet troubleshooting guide is of any help, please contact the Accu-Time Product Service Center, (860) 870-5000, for further assistance.

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

5-11

Page 164

Troubleshooting Guide

Chapter 5: Maintenance

This page intentionally left blank.

5-12

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02