Page 135

Chapter 4: Color Terminals

Figure 4-16

Setup Mode

Serial Setup Menu Screen Clock Address

Country Code

Auto Answer

03:44:53 Friday Nov 7, 2014 Setup Clock Address XX Country Code XX Auto Answer X

Direct or Modem

MANU-MAXIMUS-02 Revision-02

Return To Setup

3.

If the Maximus connects to a serial modem, press the “F1” key to select Clock Address. This parameter enables you to enter a number from 01–99 using the numeric keys with the value displayed in the enter of the screen. You can press the “clear” key to delete a number. With the desired number displayed, press the “enter” key to accept the number. This selection does not time out.

4.

If the Maximus connects to a serial modem, press the “F2” key to select Country Code. This parameter enables you to enter a number from 00–FF using the numeric keys for numbers and the function keys for letters. The value is displayed in the enter of the screen. You can press the “clear” key to delete a number. With the desired number displayed, press the “enter” key to accept the number. This selection does not time out.

5.

If the Maximus connects to a serial modem, press the “F3” key to select Auto Answer. This parameter enables you to select 1 Ring, 2 Rings, 3 Rings, or None (no rings) by pressing the “F3” key to scroll through the options that are displayed in the center of the screen.

6.

The Direct Or Modem parameter enables you select if the Maximus connects to the host using a serial modem or if it connects directly using a serial cable. The center of the screen shows the current setting (Direct or Modem) in the Serial Setup: field. If you want to change the displayed setting, press the “F4” key to select Direct Or Modem and display the Select Device Type screen (shown in Figure 4-17) then press the “F8” key to select Next (this changes the setting). If you pressed the “F8” key and the Select Device Type screen displays the desired setting, press the clear key to return to the Serial Setup menu screen without changing the setting.

Maximus Reference Manual

4-19

Page 136

Setup Mode

Figure 4-17

Chapter 4: Color Terminals

Select Device Type Screen (Shown with Modem Option Selected)

09:39 AM Thursday Nov 13, 2014 Select Device Type Modem

Next

7.

If the Maximus connects to a serial modem, press the”F2” key to select appropriate Country Code for your modem (e.g., the T.35/D1/J1 country code for the United States is B5 while the S1 code is 22). This parameter enables you to enter a number from 00–FF using the numeric keys for numbers and the function keys for letters. The value is displayed in the enter of the screen. You can press the “clear” key to delete a number. With the desired number displayed, press the “enter” key to accept the number. This selection does not time out.

8.

Press the “F8” key to select Return To Setup. Selecting this option returns you to the Setup Mode, Main Menu Screen – Host Type Serial (see Figure 4-14 on page 4-15).

Comm Port The Comm Port menu enables you to configure the serial communication port settings. These settings must match the communication software and hardware you are using to connect to the terminal. Press “F7” from the “Setup Mode, Main Menu Screen, Host Type Serial screen” (see Figure 4-14 on page 4-15) to access the Comm Port menu screen as shown in Figure 4-18.

4-20

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 137

Chapter 4: Color Terminals

Figure 4-18

Setup Mode

Comm Port Menu Screen

Baud Rate

03:42:04

Data Bits

Friday Nov 7, 2014

Parity

Baud Rate XXXXXX Data Bits XX Parity XXX Stop Bits X

Smartcard Off

Return To Setup

Stop Bits

Use the following procedure to configure the serial communications settings:

MANU-MAXIMUS-02 Revision-02

1.

To change the Baud Rate press the “F1” key to scroll through the available rates. The currently selected value displays in the middle of the screen. The default value is 9600 baud. The options are 1200, 4800, 9600, 19200, 38400, 57600, and 115200 baud (bps).

2.

To change the value for the Data Bits parameter press the “F2” key to toggle the data bits between 7 and 8. The currently selected value displays in the middle of the screen. The default value is 7 data bits.

3.

To change the value for the Parity parameter, press the “F3” key to scroll between the parity options of odd, even, and none. The currently selected value displays in the middle of the screen. The default value is odd.

4.

To change the value for the Stop Bits parameter, press the “F4” key to toggle between 1 or 2 stop bits. The currently selected value displays in the middle of the screen. The default value is 2 stop bits.

5.

To change the value for the Smartcard, press the “F5” key to scroll between off, 1k or 4k. The currently selected value displays in the middle of the screen. Set this selection to match the storage capacity of an installed smartcard or set it to off if the Maximus is not equipped with a smartcard.

6.

Press the “F8” key to select Return To Setup and go to the Setup Mode Main Menu screen.

Maximus Reference Manual

4-21

Page 138

Setup Mode

Chapter 4: Color Terminals

Ethernet Setup The Setup TCP/IP WiFi and associated sub-menus enable you to customize the Ethernet and WiFi settings for a Maximus connected to the host via an Ethernet interface.

Figure 4-19

Ethernet Setup Screen – Ethernet Host Type Host Type Ethernet

03:38:15 Friday Nov 7, 2014

Setup TCP/IP WiFi

Setup MAC XXXX:XXXX:XXXX:XXXX Host XXX.XXX.XXX.XXX Clk XXXXXX

Device None

Set Password

Comm Port

Exit Setup

Use the following procedure too set up Ethernet host type: 1.

Use the “F1” key to toggle the host type setting to Host Type Ethernet (if the screen displays Host Type Serial).

2.

Press the “F2” key to select Setup TCP/IP Wifi. The TCP/IP Setup screen appears (for either Dynamic mode as shown in Figure 4-21 on page 4-26 or Static mode as shown in Figure 4-22 on page 4-27). The TCP/IP Setup screen enables you to specify the parameters for the Maximus Ethernet connection.

3.

On the TCP/IP Setup screen, use the “F1” key to select between TCP/IP Client and TCP/IP Server. In client mode, the terminal makes the TCP/IP connection to the designated host computer. When in this mode, the terminal does not accept a connection request from any outside device. In server mode, the terminal awaits a connection initiated by the host as follows:

4-22

•

The terminal waits for a host server to initiate a connection. The terminal does not attempt to connect to any host server, so it is the responsibility of the host server to make the connection request with a terminal. The terminal is set up to accept a single connection that can come from any host.

•

A terminal connection needs to be maintained only when the host server needs to, which reduces network traffic, such as Keep Alives.

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 139

Chapter 4: Color Terminals

Setup Mode

4.

5.

CAUTION

•

You can change the host server without needing to set up your terminals.

•

Since any host on the network can try to make a connection with the terminal, any host that knows how to communicate with the terminal can read data from the terminal.

The terminal displays the current Socket Port setting in the center of the screen. The default value is 2500. To change the displayed value: •

Press the “F5” key to select Socket Port and display the Enter the Socket Port prompt screen.

•

Use the numeric keys to type the new socket port number, up to five digits (You can press the “clear” key to delete a number) then press the enter key to apply the socket port change. The terminal returns to the TCP/IP Setup screen and displays the new value for the Socket Port field in the center of the screen. If you type an invalid socket port number the terminal displays Invalid Socket Port and returns you to the saved/default value.

Append EOT Yes adds an end-of-transmission (EOT) character to the end of the communication packet. The default value is Append EOT No. Turning this option on helps to eliminate the possibility of large packets being lost. There are some networks that limit the size of a packet that can be transmitted between devices. The Append EOT No selection does not add (append) EOT numbers.

Set “Append EOT” to No unless your communication software or networking software specifically support EOT (End Of Transmission). If you set this to Append EOT Yes and EOT is unsupported, the terminal could behave unpredictably, including not responding to input. To change the displayed Append EOT value, press the “F6” key to select between Append EOT No and Append EOT Yes. 6.

To change between Dynamic DHCP and Static IP modes press the “F2” key. If you selected Dynamic DHCP, proceed to "Dynamic Mode Settings" on page 425. If you selected Static IP proceed to "Static Mode Settings" on page 4-26.

7.

You can use the “F7” key to select between PPP Disabled and PPP Enabled. WiFi must be disabled before you can enable PPP. Use PPP Enabled to set up a GSM/GPRS terminal PPP communication for connectivity with a host server over a cellular wireless data network. To set up for GSM/GPRS support, you need a GSM/GPRS-modem-equipped terminal and a data plan from a wireless carrier. When you set this parameter to PPP Enabled, the GSM PPP Setup screen appears as shown in Figure 2 on page 4-24 with the current settings displayed in the center of the screen. To change the GSM / GPRS provider press the “F2” key to cycle through the provider options. The available providers are; stream, proximus, o2, etisalat, datalink, att-gold, att, ats-tm, O2UK, ATS-t-mobil, Wlogic-ATT, wlogic, AIS, vodafoneUK, vodafone, vodacom, vodaPAYG, telenor, t-mobil-uk, tmobile.

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

4-23

Page 140

Setup Mode

Chapter 4: Color Terminals

In addition, the GSM PPP Setup screen displays the GSM/GPRS Host IP address in the center of the screen (the IP address of a public-facing server that communicates with the terminal using the wireless data network). To change this IP address, press the “F3” key to select Host IP Address and go to the Enter the Host TCP/IP Address prompt screen. Use the numeric keys to type the new Host IP address (You can press the “clear” key to delete a number) then press the enter key to apply the change. The terminal returns to the GSM PPP Setup screen and displays the new value for the Host IP Address in the center of the screen.

Figure 4-20

GSM PPP Setup Screen

03:38:15

TCP/IP Client

Provider nnnnnnn

Host IP Address

Friday Nov 7, 2014 GSM PPP Setup Provider nnnnnn Host XXX.XXX.XXX.XXX Socket Port XXXX

Return To Setup

Socket Port

Append EOT No

PPP Enabled

Enable WiFi

Configuring WiFi

4-24

1.

To configure the WiFi interface (if installed), press the “F8” key to select Setup WiFi. PPP must be disabled before you can enable WiFi. The center of the screen displays the WiFi Signal and Version. For more information on setting up GSM/GPRS terminals, see Appendix D, "GSM/GPRS Setup".

2.

Select Next (“F8” key). The center of the screen displays the Set SSID prompt. Press the enter key to set the SSID. This will enable WiFi (if disabled). The center of the screen displays the Set SSID prompt. Use the numeric keys for numbers and the function keys for letters to define the SSID. Press the enter key when finished.

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 141

Chapter 4: Color Terminals

Setup Mode

3.

NOTE:

The center of the screen displays the Set Type of Security prompt. Press the enter key to set the security protocol type. Select Next (“F8” key) or use the clear key to scroll between the WPA2, WPA, WEP, and None options. When the terminal displays the desired option, press the enter key to set the encryption type.

We recommend using the WPA2 security protocol. WEP has many security flaws and is easily broken. WPA was introduced as an interim security enhancement over WEP and uses Temporal Key Integrity Protocol (TKIP) which is not secure and vulnerable to attack. If the terminal is set to WPA2 it may not connect to routers set to WPA/WPA2 (mixed mode). It will connect to a router set to “WPA2 Personal”.

4.

The center of the screen displays the Set Security Key prompt. Press the enter key to set a security key (password). Use the numeric keys for numbers and the function keys for letters to define the security key (password). Press the enter key when finished. The center of the screen displays Disable WiFi.

5.

If you want to diable the WiFi press the enter key at the Disable WiFi prompt. Press the clear key or select Next (“F8” key) to proceed while leaving WiFi enabled. The center of the screen displays Exit WiFi Setup.

6.

Press the enter key if you want to exit the WiFi setup menu and return to the previous menu or select Next (“F8” key) to proceed. If you selected Next the center of the screen displays Set Factory Defaults.

7.

If you want to return the WiFi interface to the factory default settings press the enter key (a confirmation prompt will appear). Otherwise you can select Next (“F8” key) to go to the start of the WiFi menu or select Prev (“F7” key) or the clear key to return to the Exit WiFi Setup prompt.

8.

When you are finished, press the enter key to go back to the TCP/IP Setup screen.

9.

When you are finished with the Setup TCP/IP WiFi menu select Return To Setup (“F4” key).

Dynamic Mode Settings In DHCP mode, the IP address of the terminal is determined by the DHCP server on the local network. The IP address of the terminal might change periodically, based on the DHCP server. The center of the display shows the current DHCP settings.

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

4-25

Page 142

Setup Mode

Figure 4-21

Chapter 4: Color Terminals

TCP/IP Setup – Dynamic Mode

03:38:15

TCP/IP Client

Friday Nov 7, 2014

Dynamic DHCP

Socket Port XXXX DHCP OptionCode XXX Clk XXXXXXXXX WiFi XXXXXXX

DHCP Option Code

Return To Setup

Socket Port

Append EOT No

PPP Disabled

Setup WiFi

Use the following procedure to configure the Dynamic Mode Ethernet settings: 1.

Press the “F3” key to select the DHCP Option Code parameter. At the Enter the DHCP Option Code prompt screen, use the numeric keys to type an option code then press the enter key (You can press the “clear” key to delete a number). The DHCP Option Code allows for customizable configurations beyond the standard DHCP options. Different option codes could be used to provide information to and from the terminal, provided the terminal is programmed to use the information and the DHCP server is configured to transmit the information. •

Options 1–127 are reserved for definition by the Internet Assigned Numbers Authority (IANA) for public standardization. Some are used and some are not. For example, option 117 specifies the order in which name services should be consulted when resolving host name and other information.

•

Options in the range of 128–254 are user configurable and have no standard definition. For example, the terminal supports a list of up to five additional hosts that can be specified using the UCS command ENETHOST.

•

Alternatively, the terminal could send the DHCP server a DHCP request with option code 128, and if the server were configured appropriately, the server would respond with a list of hosts for the terminal to connect to.

Static Mode Settings In static mode, the IP address of the terminal is entered at the terminal and does not change unless changed at the terminal. The center of the display shows the current socket port.

4-26

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 143

Chapter 4: Color Terminals

Figure 4-22

Setup Mode

TCP/IP Setup – Static Mode

03:38:15

TCP/IP Client

Friday Nov 7, 2014

Static IP

Socket Port XXXX DHCP OptionCode XXX Clk XXXXXXXXX WiFi Enabled

IP Addresses

Return To Setup

Socket Port

Append EOT No

PPP Disabled

Setup WiFi

Use the following procedure to configure the Static Mode Ethernet settings: 1.

MANU-MAXIMUS-02 Revision-02

Press the “F3” key to select IP Addresses access the Secondary TCP/IP Setup screen (shown in Figure 4-23). The center of the Secondary TCP/IP Setup Screen displays: •

Host: the host IP address.

•

Clk: the IP address for the terminal.

•

Rtr: the IP address for the “router” (Gateway).

•

DNS: The IP address of the DNS server.

Maximus Reference Manual

4-27