Page 58

Setup, Test, Diagnostics, and Maintenance

This value is the amount of time, in minutes, the terminal will wait after a processor halt before doing an automatic reset. Enter a timeout value using the numeric keypad. The valid range is 00 to 60. If you enter a value greater than 60, the value will be set to 60. Setting the value to 00 disables the watchdog timer. ATS recommends leaving this value at 00. Press the CLEAR key to erase an entered value. Press the ENTER key to enter the value. After you set the timeout value, control will go to the next setup screen, setting a password.

Cyber Series terminals are shipped with a blank password, so there is no password protection. Anyone can press the Clear and Enter keys at the same time and enter TSD mode. You can define a numeric password value for a teminal in the range 0000001 through 9999999 so only authorized persons can enter TSD mode and change settings. You can also use the function keys F1 through F8 as password “digits.” If you press ENTER at the Setup Password screen, the display will show:

ENTER NEW PASSWORD _

Enter the desired password value using the numeric keypad. Press the CLEAR key to back up a digit. Press the ENTER key to enter the value. The display will show:

CONFIRM PASSWORD _

Enter the same value again, followed by the ENTER key. The terminal is now password-protected. If you make a mistake and type a different value when confirming the password, the screen will display “Invalid Password.” Press the Clear or ENTER key to continue. Control will go to the next setup screen, Setup RAM. Note: Be sure you record the password value and keep it in a safe place so you don’t forget or lose it! Without the password, you will not be able to set up or test the terminal.1 You can remove password protection by creating a blank password. Press the ENTER key at the password input prompt without entering any value.

1 - If you have this problem, contact Accu-Time Systems for recovery assistance. Cyber Series Time and Attendance Terminals

3 - 21

Introduction

Setting a Password

Page 59

Setup, Test, Diagnostics, and Maintenance

Setting RAM

If you press the ENTER key to select Setup RAM, the following screen will appear:

CLEAR ALL MEMORY! [Enter] to Proceed

Note: Clearing memory is not always required or desirable. If you have data (punches) stored in the terminal, they will be lost if you clear memory. If the terminal does contain data, you may want to peform only the setup steps required to establish host and clock communication. Then you can poll the terminal to retrieve the data before you clear memory. Press the CLEAR key if you do not want to clear memory. Control will go to the next setup screen, Exit Setup. Press the ENTER key to clear the terminal memory. If you press the ENTER key, the following display will appear:

Press the CLEAR key if you do NOT want to clear memory. Control will go to the next setup screen, Exit Setup. Press the ENTER key to clear the terminal memory. The terminal will clear memory, cycle through several displays, and return to the Terminal Locked display (Figure 3-1) that appears when the terminal is powered up.

Exiting Setup

Diagnostics Mode

If you press the ENTER key to exit setup mode, a display will appear asking if you want to perform a hardware reset. Select Yes or No using the CLEAR key, then press the ENTER key. (ATS strongly recommends you always select Yes to do a hardware reset.) After performing a reset, if that was your choice, control will go to the Enter Diagnostics screen, shown in Figure 3-2.

Cyber Series terminals can provide selected information to help diagnose problems that may occur. Accu-Time Systems may ask you to provide this diagnostic information if you call to report a problem. Figure 3-7 shows the sequence of diagnostic screens. Press the CLEAR key to cycle through the series of screens Press the ENTER key to display that screen’s corresponding diagnostic information. Return to a previous screen by pressing the F8 key.

Cyber Series Time and Attendance Terminals

3 - 22

Introduction

CLEAR ALL MEMORY! [Enter] to Confirm

Page 60

Setup, Test, Diagnostics, and Maintenance

Figure 3-7: Sequence of Diagnostics Screens

ATS Diagnostics Mode ENTER Software Versions

CLEAR

F8

ATS Diagnostics Mode ENTER Ethernet Diag

CLEAR

F8

ATS Diagnostics Mode ENTER Serial Number

F8

Introduction

CLEAR

ATS Diagnostics Mode ENTER G-10 Number

CLEAR

F8

ATS Diagnostics Mode ENTER RTC Diagnostic

CLEAR

F8

ATS Diagnostics Mode ENTER RAM Amount

CLEAR

F8

ATS Diagnostics Mode ENTER Exit Diag. Mode

CLEAR

Cyber Series Time and Attendance Terminals

3 - 23

Page 61

Setup, Test, Diagnostics, and Maintenance

The version numbers of the software installed in a Cyber Series terminal are displayed on a sequence of screens, as shown in Figure 3-8. If you select Software Versions diagnostics by pressing the ENTER key, the first screen shown in Figure 38 will appear. Cycle through the screens by pressing the CLEAR key. Move on to the Ethernet Diagnostics screen by pressing the ENTER key. Return to a previous screen by pressing the F8 key.

Introduction

Software Versions

Cyber Series Time and Attendance Terminals

3 - 24

Page 62

Setup, Test, Diagnostics, and Maintenance

Figure 3-8: Software Version Display Sequence From Program Number display

CSL Config Version nnn

CLEAR

To CSL Config display Optional screen; present only if biometric finger scan reader installed and selected for the AUX1 port ENTER

Introduction

F8

Devices Version nn/nn/nn nn:nn:nn

CLEAR

CLEAR ENTER

F8

Drivers Version nn/nn/nn nn:nn:nn

CLEAR

FPR Identify Version ENTER xx.xx_xxxx xx.xx

F8

Firmware Version nn/nn/nn nn:nn:nn

CLEAR

ENTER

ENTER

F8

TCP/IP Stack Version ENTER nn/nn/nn nn:nn:nn

CLEAR

F8

Program Version nn/nn/nn nn:nn:nn

CLEAR

ENTER

F8

Program Number nnnn/nnn

CLEAR

F8

To FPR Identify display (if hardwrae present); Otherwise, to CSD Config display

Ethernet Diagnostics

Cyber Series Time and Attendance Terminals

3 - 25

Page 63

Setup, Test, Diagnostics, and Maintenance

Ethernet Diagnostics

If you request Ethernet diagnostic information and Ethernet hardware is present, the following display appears:

Ethernet Hardware Detected Rev. 91

When you press the CLEAR key, the following screen will appear:

Ethernet MAC Address XX-XX-XX-XX-XX-XX

Press the CLEAR key to proceed to the Physical Connection Mode display. If no Ethernet hardware is available, the following screen appears:

Press the CLEAR key to proceed to the Serial Number display, or press the ENTER key to return to the previous diagnostic display. Press the F8 key to back up to the Software Versions display.

Physical Connection Mode

Following the Ethernet MAC Address display, the following display will appear::

Phy. Connection Mode xxxxxxxxxxx

This display will show the type of connection mode set in the terminal. Press the CLEAR key to advance to the Unit ID display.

Unit ID

Following the Physical Connection Mode display, the following display will appear:

UNIT ID: ATSnnnnnn

Cyber Series Time and Attendance Terminals

3 - 26

Introduction

Ethernet Hardware Not Detected

Page 64

Setup, Test, Diagnostics, and Maintenance

Press the CLEAR key to advance to the Static Client Host Port display.

Static Client Mode Host Port

Following the Unit ID display, the following display will appear:

Static Client Mode Host Port: nnnnn

Press the CLEAR key to advance to the Host IP display.

Host IP

Following the Static Client Mode Host port display, the following display will appear:

HOST IP: nnnnnnnnnnn

Clock IP

Introduction

Press the CLEAR key to advance to the Clock IP display.

Following the Host IP display, the following display will appear:

CLOCK IP: nnnnnnnnnnn

Press the CLEAR key to advance to the Subnet Mask display.

Subnet Mask

Following the Clock IP display, the following display will appear:

SUBNET MASK: nnnnnnnnnnn

Press the CLEAR key to advance to the Serial Number display.

Cyber Series Time and Attendance Terminals

3 - 27

Page 65

Setup, Test, Diagnostics, and Maintenance

Serial Number

The Serial Number display begins with a header screen:

ATS DIAGNOSTICS MODE Serial Number

Press the ENTER key to display the terminal’s serial number, the CLEAR key to advance to the G-10 number display, or the F8 key to back up to the Ethernet Diagnostics display. If you request serial number diagnostic information, the following display appears.

Terminal Serial #: nnnnnnnnnnn

G-10 Number

The G-10 number identifies the PC board used in the terminal. Accu-Time Systems may ask you for this number if you contact the ATS support group for assistance. If you request the G-10 number, the following display appears:

G10#: nnnnnnnnnn

Press the CLEAR key to proceed to the next diagnostic display, or press the ENTER key to return to the previous diagnostic display. Press the F8 key to back up to the Serial Number display.

RTC Diagnostic

If you request the RTC (real-time clock) diagnostic, the following display appears:

RTC Diagnostic Date Format: MMDDYY

Cyber Series Time and Attendance Terminals

3 - 28

Introduction

Press the CLEAR key to proceed to the next diagnostic display, or press the ENTER key to return to the previous diagnostic display. Press the F8 key to back up to the Ethernet Diagnostics display.

Page 66

Setup, Test, Diagnostics, and Maintenance

This screen shows the current setting used by the terminal for displaying the date. This example shows MMDDYY. Press the CLEAR or ENTER key to advance to the next RTC diagnostic screen:

RTC Diagnostic DST Active

This screen shows you the current terminal setting for daylight savings time. Press the CLEAR or ENTER key to advance to the next RTC diagnostic screen:

RTC Diagnostic MM/DD/YY hh:mm:ss

RAM Amount

If you request the amount of RAM available in the terminal, the following display appears:

RAM Amount Config: nnnK

Press the CLEAR key to proceed to Exit Diagnostic Mode display, or press the ENTER key to display the amount of RAM available in each memory bank. Press the F8 key to back up to the G-10 Number display.

If you press the ENTER key, a series of displays of the following form will appear:

RAM Blocks Bank n: Largest Free: nnnnn Total Free: nnnnn

Press the CLEAR or ENTER key to step through the series of displays. After displaying information about the last memory bank, the next key press will advance to the Exit Diagnostic Mode display.

Cyber Series Time and Attendance Terminals

3 - 29

Introduction

This screen shows the current values for the date and time stored in the terminal. (If the date display for your terminal is set for a different format, the display will reflect that setting.) The time that is displayed will increment once a second. Press the CLEAR or ENTER key to advance to the RAM Amount diagnostic display.

Page 67

Setup, Test, Diagnostics, and Maintenance

The following screen will apear after the final diagnostics display:

ATS DIAGNOSTICS MODE: Exit Diag. Mode

Press the CLEAR key to return to the beginning of the Diagnostics screen sequence, or press the ENTER key to exit Diagnostics mode. Press the F8 key to back up to the RAM Amount display. If you press the Enter key, the following display will appear:

ATS TSD Mode Exit TSD Mode

Press the Enter key to exit TSD mode.

Introduction

Exit Diagnostic Mode

Cyber Series Time and Attendance Terminals

3 - 30