Page 48

Setup, Test, Diagnostics, and Maintenance

If you press the ENTER key to select COMM port setup, the follow screen will appear:

SETUP COMM PORT RS232 19200 8 NONE

This screen lets you choose protocol, baud rate, number of data bits, and parity. The choices for each parameter are shown in Table 3-1:

Table 3-1: COMM Port Setup Parameters Parameter

Choices

Protocol

RS232, RS485

Baud rate

115200 (not currently supported), 57600, 38400, 28800, 19200, 14400, 9600, 4800, 2400, 1200

Data bits

7, 8

Parity

Odd, Even, None

Cycle forward through the choices for each parameter, beginning with the protocol type, by pressing the CLEAR key. Cycle backward by pressing the F8 key. Select a parameter value and move to the next parameter by pressing the ENTER key. The values for you select for number of data bits and for parity determine what happens next. If you select 8 data bits and no parity, the following screen will appear:

SETUP COMM PORT Stop Bits: 2

Cycle forward through the choices (1 or 2) by pressing the CLEAR key. Make your selection by pressing the ENTER key. This option, in conjunction with the data and parity selections, lets you configure the following serial framings:

Table 3-2: Possible Serial Framings Data Bits

Parity

Stop Bits

7

Odd

1

10 bits

7

Even

1

10 bits

Frame Size

Cyber Series Time and Attendance Terminals

3 - 11

Introduction

Setting the COMM Port

Page 49

Setup, Test, Diagnostics, and Maintenance

Table 3-2: Possible Serial Framings (Continued) 7

None

2

10 bits

8

None

1

10 bits

8

Odd

1

11 bits

8

Even

1

11 bits

8

None

2

11 bits

After you select the number of stop bits, or if you selected other than 8 bits, no partiy, control will go to the next COMM setup screen, setting flow control:

This screen lets you choose the type of flow control: NONE, or RTS/CTS. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Select a parameter value and move to the next screen, Setup AUX1 Port, by pressing the ENTER key. You now select the type of device, if any, connected to the COMM port. The following screen will appear:

SETUP COMM PORT Device: None

Possible choices for device are None, Modem, or Printer. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. If you are using the COMM port for a direct serial connection to the host, choose None. If have a modem or printer connected to the COMM port, cycle the display to the correct choice and press the ENTER key. (Note: do not select “Printer” here if you connect the print to the AUX1 port. If you select Printer, set the COMM port’s baud rate to 9600 baud.)

Setting the AUX1 Port

If you pressed the ENTER key to select Setup AUX1 port (it may be labeled DIDO on the back of the terminal), the following screen will appear:

SETUP AUX1 PORT BAUD Rate: 9600

Cyber Series Time and Attendance Terminals

3 - 12

Introduction

SETUP COMM PORT Flow Ctrl: NONE

Page 50

Setup, Test, Diagnostics, and Maintenance

Possible values for the AUX1 port baud rate are 115200 (not currently supported), 57600, 38400, 28800, 19200, 14400, and 9600. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Choose the baud rate you want by pressing the ENTER key. Be sure to note the individual device baud rate requirments given in Table 3-3. After you set the AUX1 port baud rate, the following screen will appear:

SETUP AUX1 PORT Device: NONE

Table 3-3 lists the possible AUX1 port devices:

Device

Details

Fingerprint

Finger scan reader (For this device, set baud rate to 57600.)

Finger Geom.

Finger geometry reader. (For this device, set baud rate to 9600.)

MODEM

Modem.

Printer

Printer. (Note: do not select “Printer” here if you connect the printer to the COMM port. If you select Printer, set the AUX1 port’s baud rate to 9600 baud.)

NONE

No AUX1 device.

Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Choose the device you want by pressing the ENTER key. After you select the AUX1 port device, control will go to the next setup screen, Setup Display.

Setting the Display

If you pressed the ENTER key to select Setup Display , the following screen will appear:

SETUP DISPLAY Number of Lines: 4

Possible values for the number of display lines are 2 or 4. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Choose the number that corresponds to your terminal’s display by pressing the ENTER key. After you choose the number of display lines, control will go to the next setup screen, Setup Host Connect. The new display setting will take effect the next time power to the terminal is turned off, then on. Cyber Series Time and Attendance Terminals

3 - 13

Introduction

Table 3-3: AUX1 Port Devices

Page 51

Setup, Test, Diagnostics, and Maintenance

Setting Host Connect

If you pressed the ENTER key to select Setup Host Connect, the following screen will appear:

SETUP HOST CONNECT Type: ATS COMM Poll

This screen lets you select the data transport protocol. The choices are ATS COMM Poll, TCP/IP, and Digi One. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Choose a protocol by pressing the ENTER key.

If you pressed the ENTER key to select ATS COMM Poll, the following screen will appear:

SETUP HOST CONNECT Enter Clock Adrs: 01

Valid terminal ID values range from 01 to 32. (Note: if you specify a value greater than 32, the terminal ID will be set to 32.) Enter a terminal ID value using the numeric keypad. Press the CLEAR key to erase a value. Press the ENTER key to accept it. After you specify a terminal ID, the following screen will appear:

SETUP HOST CONNECT Select App. Type: A

This screen lets you assign a letter code to identify the type of application that will run in the terminal. For example, for your business you may have some terminals running a strict time and attendance application, while other terminals may be on a shop floor running an application that also processes job ticket information. By assigning an application identifier to the terminal, you can identify which terminals should receive a particular application update when terminals are reprogrammed. Valid values for AppType are A through J. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Select a value by pressing the ENTER key. After you select a value, control will go to the next setup screen, setting host connect.

Cyber Series Time and Attendance Terminals

3 - 14

Introduction

Configuring ATS COMM Poll

Page 52

Setup, Test, Diagnostics, and Maintenance

After you select an AppType, the following screen will appear:

SETUP HOST CONNECT MODEM: Disable

Valid values are Enable and Disable. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Choose a setting by pressing the ENTER key. If you choose Disable, control will go to the screen Setup Reader1. If you choose Enable, the following screen will appear:

Set the appropriate country code (00 through 99) by entering the digits on the keypad. When you have set the value, press the ENTER key to go the Auto Answer screen:

SETUP HOST CONNECT Auto Answer: 1

Valid values for Auto Answer are None, 1 ring, 2 rings, or 3 rings. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Select a value by pressing the ENTER key. After you select a value, the terminal will try to initialize the modem. If initialization succeeds, control will go to the screen to Setup Reader1. If initialization fails, the following screen will appear:

Modem Init. Failed Press any key

When you press a key, control will go back to the screen, Setup Host Connect.

Cyber Series Time and Attendance Terminals

3 - 15

Introduction

SETUP HOST CONNECT Country Code: 99

Page 53

Setup, Test, Diagnostics, and Maintenance

If you choose TCP/IP for host connect, the following screen will appear:

SETUP SOCKET Type: Client Mode

Choices are Client Mode or Server Mode. Make this selection by pressing the ENTER key.

In client mode, the terminal makes the TCP/IP connection to the designated host. When in this mode, it will not accept a connection request from any outside device. In server mode, the terminal listens for a host connection. The terminal does not attempt to connect to any host. Therefore it becomes the host’s responsibility to make the connection request with any given terminal. The terminal is set up such that it will accept a single connection, and this connection can come from any host. Server mode has advantatages and disadvantages. A terminal connection needs to be maintained only when the host wants to, thereby eliminating a lot of network traffic, like Keep Alives. The host can also be changed, therefore a new IP, without requiring resetting up each and every terminal. On the negative side, any host on the network can try to make a connection with the terminal. If that host were "predatory" and knew how to communicate with the terminal, it could read data from the terminal. The following screen will appear:

SET CONNECTING SOCKET PORT: 02500

Enter a socket number on the keypad. When you have entered the value, press the ENTER key. The following screen will appear:

SETUP ADDRESSING Type: Static TCP/IP

Choices are Static TCP/IP or Dynamic DHCP. Cycle through the list of choices by pressing the CLEAR key. Make your selection by pressing the ENTER key.

Cyber Series Time and Attendance Terminals

3 - 16

Introduction

Configuring TCP/IP

Page 54

Setup, Test, Diagnostics, and Maintenance

Dynamic DHCP

If you select Dynamic DHCP, the following screen will appear:

SET DHCP OPTION HOST CODE: 128

Valid values are 128 through 255. Default is 128. This is the option code the terminal will use to read a list of up to five host IP addresses from the server. Enter a value using the numeric keypad. Press the ENTER key after entering the last digit. For more details on setting up the DHCP option code on the DHCP server, refer to Setting Up the DHCP Option Code on page 3-35. The terminal’s DHCP support uses standard DHCP conventions. It does automatic lease renewal and uses only standard option codes in the range 0 through 127 that any network DHCP server would be expected to support. After setting the DHCP option host code, control will go to the Setup Etherenet Mode screen shown below. If you select Static TCP/IP, the following screen will appear:

Setup Clock IP 000.000.000.000

Introduction

Static TCP/IP

“Clock” refers to the terminal. Enter an IP address for the terminal using the numeric keypad. Press the CLEAR key to to back up a digit. Press the F8 key to skip a digit. Press the ENTER key after entering the last digit. The following screen will appear:

Setup Host IP 000.000.000.000

Enter the IP address of the host computer with which the terminal will communicate, just as you entered the IP address of the terminal. Press the ENTER key after entering the last digit. The following screen will appear:

Setup Sub-Net Mask 000.000.000.000

Cyber Series Time and Attendance Terminals

3 - 17

Page 55

Setup, Test, Diagnostics, and Maintenance

Enter the appropriate network subnet mask. Press the ENTER key after the last digit. The following screen will appear:

Setup Router IP: NO

The choices are Yes and No. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Make a selection by pressing the ENTER key. If you select No, control will go to the next setup screen, setting reader1. If you choose to set up a router by selecting Yes, the following screen will appear:

Enter a router IP address using the numeric keypad, as you did for the terminal and host IP addresses. Press the ENTER key after the last digit. The display will advance to the Setup Ethernet Mode screen.

Setup Ethernet Mode

The Setup Ethernet Mode screen lets you set the data transmission mode. The screen shown below appears:

SETUP ETHERNET MODE Auto Negotiate

The choices are:

• • • • •

Auto Negotiate 100MBit Full Duplex 100MBit Half Duplex 10MBit Full Duplex 10MBit Half Duplex

Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Make a selection by pressing the ENTER key. ATS recommends you choose Auto Negotiate unless you have a specific hardware reason not to.

Cyber Series Time and Attendance Terminals

3 - 18

Introduction

Setup Router IP 000.000.000.000

Page 56

Setup, Test, Diagnostics, and Maintenance

Next, the following screen will appear:

Append TCP Data with EOT: NO

Choices are YES or NO. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Make a selection by pressing the ENTER key. If you select YES, the terminal will append an EOT character (0416) to each transaction record sent to the host. After you make your selection, the terminal will ask if you want to initilize the TCP/ IP stack. Select Yes or No using the CLEAR key, then press the ENTER key. The terminal will initializet he stack, if that is your choice, then control will go to the next setup screen, setting reader1.

If you press the ENTER key to select reader1 setup, the following screen will appear:

SETUP READER1 DEVICE Optical/Magnetic

This screen lets you specify the type of reader being used. The choices are Optical/ Magnetic and Proximity/Wiegand. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Make a choice by pressing the ENTER key. After you make your selection by pressing the ENTER key, control will go to the next setup screen, setting date and time.

Setting Date and Time

If you press the ENTER key to select date and time setup, the following screen will appear:

SELECT DATE FORMAT MM/DD/YY

Cyber Series Time and Attendance Terminals

3 - 19

Introduction

Setting Reader1

Page 57

Setup, Test, Diagnostics, and Maintenance

Cyber Series terminals support three date formats: MM/DD/YY, YY/MM/DD, and DD/MM/YY. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Make a choice by pressing the ENTER key. After you make your selection by pressing the ENTER key, the following screen will appear:

SET RTC DATE & TIME nn/nn/nn nn:nn:nn

The date displayed will be in the format just chosen (MM/DD/YY, YY/MM/DD, or DD/MM/YY). Set the current date and time using the numeric keypad. Press the CLEAR key to to back up a digit. Press the F8 key to skip a digit. Press the ENTER key to enter the value. The terminal does not check for the validity of entered date or time values. The terminal will accept, for example, a date of 99:99:99.

DAYLIGHT SAVINGS Enable

Cyber Series terminals can automatically adjust for daylight savings time. When the terminal detects a time change, it will send the transaction: DS00rsYYMMDDHHMMSSrs (rs = record separator) to let the host know exactly when the terminal changed over to or from daylight savings time. Possible values are Enable and Disable. Cycle forward through the list of choices by pressing the CLEAR key. Cycle backward by pressing the F8 key. Make a selection by pressing the ENTER key. After you make the selection, control will go to the next setup screen, setting a watchdog timeout.

Setting a Watchdog Timeout

Cyber Series terminals offer a watchdog timer that will reset the terminal if a processor halt occurs. If you press the ENTER key to select watchdog setup, the following screen will appear:

SET WATCHDOG TIMEOUT In Minutes: 00

Cyber Series Time and Attendance Terminals

3 - 20

Introduction

After you enter the date and time, the following screen will appear: