For the Accu-Time CS2100 and Accu-Time CSS110

Page 38

Chapter 3

Power-Up

Setup, Test, Diagnostics, and Maintenance

Connect an ATS 12VDC power supply locally or remotely to the terminal. When power is applied to the terminal, the terminal will beep, execute a power-up sequence, and display the text shown in Figure 3-1. The “Waitng for host” message indicates that the terminal is ready to accept a program download. This is the normal condition on initial power-up. The numeric value nnnn-nnn is the version number of the firmware installed in the terminal. The descriptions in this chapter apply to firmware version 6001-075. If your terminal has an earlier or later firmware version, your setup, diagnostic, and test screens may vary slightly from those described. The functionality, however, will be similar. Figure 3-1: Initial Power-Up Display

WAITING FOR HOST PGM: nnnn-nnn-nnn

“Waiting for host” means the terminal is waiting for a program download and will not accept any user input. To load the terminal: 1. Configure the terminal’s communication and operating characteristics. Refer to Entering Test, Setup, and Diagnostic Mode on page 3-2 for details. 2. Send a download file to the terminal to program the terminal’s operation. Cyber Series terminals use the ATS Universal Command Set (UCS). Refer to the Universal Command Set Reference Manual, MANU0000-11, for details.

Cyber Series Time and Attendance Terminals

3-1

Page 39

Setup, Test, Diagnostics, and Maintenance

Cyber Series terminals have a built-in test, setup, and diagnostic mode (TSD mode). For details of each capability, refer to Test Mode on page 3-3, Setup Mode on page 3-9, and Diagnostics Mode on page 3-22. To enter TSD mode: 1. Press and hold the CLEAR and ENTER keys simultaneously for about 5 seconds. 2. The Cyber Series terminal will beep, then display the test, setup, or diagnostic menu selection sequence shown in Figure 3-2. The menu selection sequence begins with the choice to enter test mode. Cycle through the list by pressing the CLEAR key. Choose one of the modes by pressing the ENTER key. Return to a previous menu by pressing the F8 key. Note: You can enable password protection so only authorized persons can enter TSD mode. See Setting a Password on page 3-21 for details. Figure 3-2: Test, Setup, or Diagnostic Menu Selection

ATS TSD MODE Enter Test Mode

CLEAR

ENTER

Setup mode

F8

ATS TSD MODE Enter Diagnostics

CLEAR

Test mode

F8

ATS TSD MODE Enter Setup Mode

CLEAR

ENTER

Introduction

Entering Test, Setup, and Diagnostic Mode

ENTER

Diagnostics

F8

ATS TSD MODE Exit TSD Mode

ENTER

“Waiting for Host”

CLEAR

Cyber Series Time and Attendance Terminals

3-2

Page 40

Setup, Test, Diagnostics, and Maintenance

ATS Test Mode checks the functionality of the terminal keypad, display, memory, real time clock, card reader, and bar code wand circuitry. When you press the ENTER key to enter test mode, the terminal will briefly display the message, “Enter or Clear To Continue,” then display a screen of filled-in character blocks as shown in Figure 3-3. Press the CLEAR key to continue with Test mode, or press the ENTER key to return to the next menu shown in Figure 3-2. Figure 3-3: Initial Test Mode Display

Enter or Clear To Continue

ENTER

Enter Setup Mode screen

CLEAR

Continue with Test Mode Figure 3-4 shows the sequence of the test mode screens. Pressing the CLEAR key proceeds to the next test, while pressing the ENTER key returns to the previous test. Each test is described in the following sections: • Testing the Reader or Wand on page 3-6 • Testing the Real-Time Clock (RTC) on page 3-6 • Testing the Keypad on page 3-6 • Testing Low Power on page 3-6 • Testing Serial RS232 on page 3-6 • Testing Serial RS485 on page 3-7 • Testing the Serial AUX on page 3-7 • Testing DIDO on page 3-7 • Testing the Modem on page 3-7 • Testing the Finger Scanner on page 3-7 After going through all the tests, pressing the CLEAR key transfers control to the Enter Setup Mode screen (Figure 3-2). Cyber Series Time and Attendance Terminals

3-3

Introduction

Test Mode

Page 41

Setup, Test, Diagnostics, and Maintenance

Figure 3-4: Sequence of Test Mode Screens Test Reader or Wand

ENTER

------------

Previous screen

From Test Serial AUX screen

CLEAR

ENTER

Previous screen

ENTER

Previous screen

CLEAR

ENTER

Previous screen

Test Modem Host Echo Press Enter to Test ENTER

To modem test

CLEAR

ENTER

Previous screen

To Test Finger Print sequence e(if enabled) or Enter Setup Mode Optional test. This screen appears only if modem is enabled.

CLEAR

Test Serial RS485

ENTER

Previous screen

CLEAR

Test Serial RS232 screen

Test DIDO 3 & 4

CLEAR

Test Low Power

ENTER Previous

CLEAR

CLEAR

Test Keypad

Test DIDO 1 & 2

Introduction

Test RTC

ENTER

Previous screen

CLEAR

Test Serial AUX

ENTER

Previous screen

CLEAR

Cyber Series Time and Attendance Terminals

3-4

Page 42

Setup, Test, Diagnostics, and Maintenance

Figure 3-5: Optional Test Finger Print Sequence From previous test screen

Test Finger Print Press Enter to Test

ENTER

CLEAR

To Enter Setup Mode screen

Initializing Reader

IF NO READER,

Introduction

ENTER SETUP

Test Finger Enroll Place Finger

Quality = nn Content = nn

IF ENROLL FAILS

Test Finger Verify Place Finger IF VERIFY FAILS

Verify Passed nn%

Cyber Series Time and Attendance Terminals

3-5

Page 43

Setup, Test, Diagnostics, and Maintenance

Testing the Reader or Wand

To test the reader or wand, swipe a badge through the terminal’s reader or scan a code with the wand. Verify that the proper value is displayed on the screen. Press the CLEAR key to continue to the next test, or press the ENTER key to return to the previous test.

Testing the RealTime Clock (RTC)

The RTC test checks the real-time clock. When you select this test, the display shows the current date and time stored in the terminal, blinks the green LED and beeps twice a second, and increments the time display once a second. Check that the settings are correct and that the time is incrementing properly. (If the date or time are incorrect, you can set the values using Setup mode.) Press the CLEAR key to continue to the next test, or press the ENTER key to return to the previous test.

To test the keypad, press in sequence the keys 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, F1, F2, F3, F4, F5, F6, F7, F8. Each key should echo (display), the green “Valid” LED should blink, and the terminal should give a short beep. The function keys echo as A, B, C, D, E, F, G, H. If you press a key out of sequence, or if there is an error, the key will not echo, the red “Invalid LED will blink, and the terminal will give a longer beep. Control will automatically proceed to the low power test selection screen after you press the F8 key. Press the CLEAR key to continue to the next test, or press the ENTER key to return to the previous test.

Testing Low Power

The low power test is applicable only if a terminal has the battery backup option. To test the low power warning, first ensure the battery backup is installed. Then unplug the +12VDC power supply from the terminal. The low power warning LED on the front of the terminal should light up and the display should read POWER LOW. The low power warning light should go out when you plug the +12VDC power supply connector back into the terminal (normal power). Press the CLEAR key to continue to the next test, or press the ENTER key to return to the previous test.

Testing Serial RS232

When you select the RS232 test screen, the terminal will perform an internal loopback test of the RS232 circuit. The green “Valid” LED should blink and the terminal beep approximately twice a second. (You can press 1 on the keypad to toggle the beep off or on.) Pressing F2 will test the external network. Pressing F1 will return to the internal (default) test. Cyber Series Time and Attendance Terminals

3-6

Introduction

Testing the Keypad

Page 44

Setup, Test, Diagnostics, and Maintenance

Press the CLEAR key to continue to the next test, or press the ENTER key to return to the previous test.

Testing Serial RS485

When you select the RS485 test screen, the terminal will perform an internal loopback test of the RS485 circuit. The green “Valid” LED should blink and the terminal beep approximately twice a second. (You can press 1 on the keypad to toggle the beep off or on.) Pressing F2 will test the external network. Pressing F1 will return to the internal (default) test. Press the CLEAR key to continue to the next test, or press the ENTER key to return to the previous test.

Testing the Serial AUX

Plug an AUX loopback connector into the AUX port. This is a connector with the transmit and receive lines tied together. A test message is sent out the port then echoed back. The message echoed should match the message sent.

Testing DIDO

Two screens let you test DIDO 1 and 2 or DIDO 3 and 4. Plug a DIDO loopback connector, available from Accu-Time Systems, into the DIDO port. The green “Valid” LED should blink and the terminal beep approximately twice a second. Press the CLEAR key to continue to the next test screen, or press the ENTER key to return to the previous test.

Testing the Modem

If you enable modem support for the COMM port or modem support for Host Connect, the Modem Host Echo test screen will appear. The Modem Host Echo test sets the terminal so it will echo characters sent to it by the host. To use the test, you should set the terminal modem to auto-answer, enable the Modem Host Echo test by pressing the ENTER key in response to the Modem Host Echo test screen, dial the terminal from a host PC, send characters to the terminal, and verify that they are properly echoed back to the host. Press the CLEAR key to continue to the next test screen.

Testing the Finger Scanner

The finger scan test lets you enroll and then verify a finger scan to test the operation of the finger scan reader. If you choose this test but there is no finger scan reader present, the screen will display Reader Not Detected! Press the CLEAR key to continue to the Enter Setup Mode screen. Press the ENTER key to return to the Test DIDO screen.

Cyber Series Time and Attendance Terminals

3-7

Introduction

Press the CLEAR key to continue to the next test, or press the ENTER key to return to the previous test.

Page 45

Setup, Test, Diagnostics, and Maintenance

If the terminal detects a reader, The screen will display:

Test Finger Enroll Place Finger

Place your finger on the finger scan window. (See Appendix A, Proper Use of a Biometric Reader, for guidelines on how to properly place your finger on the reader.) After the reader scans your finger, the screen will display:

Quality = nn Content = nn

If the quality and content values are not greater than Quality=20 and Content=40, or if you fail to place your finger on the reader, the screen will flash Enrollment Failed and return to the original Test Finger Print screen.

Introduction

If the enrollment succeeds, the screen will display:

Test Finger Verify Place Finger

Place the same finger on the reader again. If the verification meets a minimum standard for verification, the screen will display:

Verify Passed: nn%

The value nn is the actual match percentage achieved. The terminal will then return to the Test Finger Print screen. If the verification fails to meet the minimum match criteria, the screen will display Verify Failed and return to the Test Finger Print screen. Failure will also occur if a finger is not placed on the reader, the finger is placed incorrectly, or if the wrong finger is used.

Cyber Series Time and Attendance Terminals

3-8

Page 46

Setup, Test, Diagnostics, and Maintenance

Use ATS Setup Mode to configure the operating parameters of the terminal. Figure 3-6 shows the selection of screens available in setup mode. Step through the sequence of setup screens by pressing the CLEAR key on the terminal. Press the ENTER key to choose a particular setup selection. Return to a previous screen by pressing the F8 key. The details of each setup choice are explained in individual sections, below. • Setting the COMM Port on page 3-11 • Setting the AUX1 Port on page 3-12 • Setting the Display on page 3-13 • Setting Host Connect on page 3-14 • Setting Reader1 on page 3-19 • Setting Date and Time on page 3-19 • Setting a Watchdog Timeout on page 3-20 • Setting a Password on page 3-21

Introduction

Setup Mode

• Setting RAM on page 3-22 • Exiting Setup on page 3-22

Cyber Series Time and Attendance Terminals

3-9

Page 47

Setup, Test, Diagnostics, and Maintenance

Figure 3-6: Sequence of Setup Mode Screens ATS SETUP MODE Setup COMM Port

F8

ATS SETUP MODE Setup AUX1 Port

CLEAR

CLEAR

F8

Back to start of list

ENTER

F8

ATS SETUP MODE Setup Watchdog

CLEAR

ENTER

ENTER

F8

ATS SETUP MODE Setup Date & Time

CLEAR

Exit Setup

CLEAR

ENTER

F8

ATS SETUP MODE

ENTER

ENTER

F8

ATS SETUP MODE Setup RAM

CLEAR

F8

ATS SETUP MODE Setup Reader1

CLEAR

ENTER

F8

ATS SETUP MODE Setup Host Connect

ATS SETUP MODE Setup Password

CLEAR

F8

ATS SETUP MODE Setup Display

CLEAR

ENTER

Introduction

CLEAR

ENTER

ENTER

F8

Cyber Series Time and Attendance Terminals