Accu-Time Cyber Series Standard, Biometric, and NEMA 4X Time and Attendance Terminals: Chapter 2 Installation, pages 30 to 37

Pages 30 to 37 of 91, from Accu-Time Cyber Series Standard, Biometric, and NEMA 4X Time and Attendance Terminals

The original document is the PDF (952 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Time CS2100 and Accu-Time CSS110

Page 30

Installation

Find the appropriate mounting template printed at the end of this chapter: • Figure 2-7, Cyber Series Locking Base Mounting Template on page 2-13 • Figure 2-8, Cyber Series Gullwing Base Mounting Template on page 2-14 • Figure 2-9, Cyber Series NEMA 4X Enclosure Mounting Template (50% Full Size) on page 2-15. • Figure 2-10, Cyber Series Finger Geometry Terminal Mounting Template on page 2-15. CAUTION: These templates were created exactly to size, but their dimensions may grow or shrink slightly when printed because of printer variations. Be sure to compare the dimenions of a printed template to the dimensions specified on the termplate to see if there is a discrepancy and adjust as necessary. Prepare the wall to accommodate mounting hardware (customer provided). A convenient mounting height for the CSx, CSxB, and CSxN terminals is 48 inches from the floor to the terminal display. CSxG terminals should be mounted such that the “keyhole” mounting holes in the backplate are about 44 1/4” above the floor. These height are compliant with the Americans with Disabilities Act. Observe OSHA and local safety codes when operating tools during all phases of the installation. Select and remove one or more of the knockouts in the terminal enclosure to accommodate the data transmission cable and the 12VDC power cable. (If you have a NEMA 4X enclosure, there are three gasketed holes in the enclosure for cable pass-through.) Attach the terminal base to the flat wall surface using screws or other fasteners in the mounting holes marked on the template. If you are installing a terminal with a separate locking base, align the front face section of the Cyber Series terminal over the terminal base. Insert the data cable through the previously-removed knockout in the terminal enclosure, or through one of the gasketed holes in the NEMA 4X enclosure, and into the appropriate communication port of the Cyber Series terminal. Use an appropriate bushing or cable clamp to secure and protect the cable where it passes through the enclosure. Ensure that the cable is terminated into the appropriate 8-conductor modular connector. Attach the other end of the data cable to the host computer port. Install the 12VDC power cable in the enclosure a similar fashion. If you have a basic Cyber Series or a biometric Cyber Series terminal, plug the output of the 12VDC power cable into the power jack of the terminal (Figure 2-5).

Cyber Series Time and Attendance Terminals

2-9

Introduction

Installing the Terminal

Page 31

Installation

If you have a Cyber Series finger geometry terminal without the battery backup option, plug the plug the output of the 12VDC power cable into a power jack on the connector board (see Figure 2-6). There are two power jacks on the connector board. Choose the one that matches the plug on the power pack cable. Plug the short power jumper cable from the connector board into the power outlet of the terminal. If your Cyber Series finger geometry terminal has the battery backup option installed, plug the plug the output of the 12VDC power cable into a power jack on the battery charger charger board mounted on the left-hand side of the base. There are two power jacks on the battery charger board. Choose the one that matches the plug on the power pack cable. Plug the short power jumper cable from the connector board into the power outlet of the terminal. Be sure the 6-pin power jumper shown in the lower illustration of Figure 2-5 and in Figure 2-6 is set correctly. If you have an older model Cyber Series terminal with a 3-pin power jumper (upper illustration in Figure 2-5), the jumper should go on the upper two pins. If you have a Cyber Series finger geometry terminal, be sure the battery jumper on the connector board is set correctly.

If the face is separate, attach the face to the terminal base after connecting the wiring. Secure the face to the base with the key lock. When 12VDC is connected, the Cyber Series terminal will power up and display its on-line default message. The Cyber Series terminal is now ready for setup and configuration. Refer to Chapter 3, Setup, Test, Diagnostics, and Maintenance for terminal setup instructions.

Cyber Series Time and Attendance Terminals

2 - 10

Introduction

Plug the primary of the power pack assembly to a conventional wall outlet.

Page 32

Installation

Figure 2-5: Cyber Series Terminal Connections and Jumpers EARTH GND

THREE-PIN POWER JUMPER +12V

PLACE JUMPER ON UPPER TWO PINS IF USING +12VDC POWER PACK DIRECT CONNECTION

GND

POWER (P7) BATTERY (P8) _ +

3 2 1

1

SERIAL (J8)

POWER

1

DIDO (J9) LINK

DIDO

BUSY

SERIAL

1

WAND ETHERNET (OPTIONAL) JTAG

ETHERNET INDICATOR LEDS (IF ETHERNET PRESENT)

WAND (J2)

1 SIO-IN (CONSULT FACTORY) 2 DIGITAL-IN 3 GND 4 +5V (CONSULT FACTORY) 5 DIGITAL-OUT 6 SIO-OUT (CONSULT FACTORY) 1 EARTH GND 2 GND 3 +5V 4 N/C 5 DATA 6 N/C

JTAG (FACTORY USE)

TWO-BOARD CYBER SERIES TERMINAL (OLD MODEL) EARTH GND

SIX-PIN POWER JUMPER +12V

STANDARD POSITION, NO MODEM

GND

POWER (P7) LINK LED

ETHERNET (OPTIONAL)

BATTERY (P8) _ +

POSITION IF MODEM INSTALLED

3 2 1

1

SERIAL (J8) POWER BATTERY

BUSY LED 1

SERIAL

DIDO (J9)

DIDO WAND

1

WAND (J2) JTAG

RS485 RS232 1 EARTH GND _ TERM REC 2 TERM REC 3 TERM TRANS TERM XMIT +_ TERM XMIT 4 TERM RTS TERM REC + 5 TERM CTS 6 PWR GND1 7 POWER (CONSULT FACTORY) 8 PWR GND2 1 SIO-IN (CONSULT FACTORY) 2 DIGITAL-IN 3 GND 4 +5V (CONSULT FACTORY) 5 DIGITAL-OUT 6 SIO-OUT (CONSULT FACTORY) 1 EARTH GND 2 GND 3 +5V 4 N/C 5 DATA 6 N/C

JTAG (FACTORY USE) SINGLE-BOARD CYBER SERIES TERMINAL

Cyber Series Time and Attendance Terminals

2 - 11

Introduction

BATTERY

RS485 RS232 1 EARTH GND _ TERM REC 2 TERM REC 3 TERM TRANS TERM XMIT +_ TERM XMIT 4 TERM RTS TERM REC + 5 TERM CTS 6 PWR GND1 7 POWER (CONSULT FACTORY) 8 PWR GND2

Page 33

Installation

Figure 2-6: Cyber Series Finger Geometry Terminal Connections

MODEM

ETHERNET

POWER BATTERY (NOT USED)

ANALOG PHONE LINE

SERIAL

DIDO

WAND PLUG IN POWER PACK (CHOOSE ONE)

NO BATT BATT

CONNECTOR BOARD

Cyber Series Time and Attendance Terminals

Introduction

FROM DIDO BOARD IN BASE

FROM BATTERY CHARGER BOARD

RIBBON CABLES FROM CAMERA

2 - 12

Page 34

Installation

Introduction

"A"

"A"

4.75" (4 3/4")

3.00"

2.37" (2 3/8")

6.00

"B"

2.37" (2 3/8")

"B"

3.28" (3 9/32")

1.47" (1 15/32")

"A"

Figure 2-7: Cyber Series Locking Base Mounting Template

Cyber Series Time and Attendance Terminals

2 - 13

Page 35

4 7/32

7 23/32

Cyber Series Gullwing Mounting Template

Figure 2-8: Cyber Series Gullwing Base Mounting Template

Page 36

Installation

0.750

0.375

0.750

6.500

0.210" HOLES, 4X

11.250

Introduction

0.375

Figure 2-9: Cyber Series NEMA 4X Enclosure Mounting Template (50% Full Size)

Figure 2-10: Cyber Series Finger Geometry Terminal Mounting Template

Cyber Series Time and Attendance Terminals

2 - 15

Page 37

6"

9/64 " 1 1/4"

Mounting Template for 2102, 3102, and CS2102 Finger Geometry Terminals

IMPORTANT!!!

8"

3/4"

2102

3102 CS2102

Terminal MUST be grounded. Refer to instructions enclosed with the ground wire inside terminal. Grounding is ESSENTIAL to proper terminal operation.

4 1/2"

45 1/4" to floor

3102 CS2102

2102