Page 30
Installation
Find the appropriate mounting template printed at the end of this chapter: • Figure 2-7, Cyber Series Locking Base Mounting Template on page 2-13 • Figure 2-8, Cyber Series Gullwing Base Mounting Template on page 2-14 • Figure 2-9, Cyber Series NEMA 4X Enclosure Mounting Template (50% Full Size) on page 2-15. • Figure 2-10, Cyber Series Finger Geometry Terminal Mounting Template on page 2-15. CAUTION: These templates were created exactly to size, but their dimensions may grow or shrink slightly when printed because of printer variations. Be sure to compare the dimenions of a printed template to the dimensions specified on the termplate to see if there is a discrepancy and adjust as necessary. Prepare the wall to accommodate mounting hardware (customer provided). A convenient mounting height for the CSx, CSxB, and CSxN terminals is 48 inches from the floor to the terminal display. CSxG terminals should be mounted such that the “keyhole” mounting holes in the backplate are about 44 1/4” above the floor. These height are compliant with the Americans with Disabilities Act. Observe OSHA and local safety codes when operating tools during all phases of the installation. Select and remove one or more of the knockouts in the terminal enclosure to accommodate the data transmission cable and the 12VDC power cable. (If you have a NEMA 4X enclosure, there are three gasketed holes in the enclosure for cable pass-through.) Attach the terminal base to the flat wall surface using screws or other fasteners in the mounting holes marked on the template. If you are installing a terminal with a separate locking base, align the front face section of the Cyber Series terminal over the terminal base. Insert the data cable through the previously-removed knockout in the terminal enclosure, or through one of the gasketed holes in the NEMA 4X enclosure, and into the appropriate communication port of the Cyber Series terminal. Use an appropriate bushing or cable clamp to secure and protect the cable where it passes through the enclosure. Ensure that the cable is terminated into the appropriate 8-conductor modular connector. Attach the other end of the data cable to the host computer port. Install the 12VDC power cable in the enclosure a similar fashion. If you have a basic Cyber Series or a biometric Cyber Series terminal, plug the output of the 12VDC power cable into the power jack of the terminal (Figure 2-5).
Cyber Series Time and Attendance Terminals
2-9
Introduction
Installing the Terminal
Page 31
Installation
If you have a Cyber Series finger geometry terminal without the battery backup option, plug the plug the output of the 12VDC power cable into a power jack on the connector board (see Figure 2-6). There are two power jacks on the connector board. Choose the one that matches the plug on the power pack cable. Plug the short power jumper cable from the connector board into the power outlet of the terminal. If your Cyber Series finger geometry terminal has the battery backup option installed, plug the plug the output of the 12VDC power cable into a power jack on the battery charger charger board mounted on the left-hand side of the base. There are two power jacks on the battery charger board. Choose the one that matches the plug on the power pack cable. Plug the short power jumper cable from the connector board into the power outlet of the terminal. Be sure the 6-pin power jumper shown in the lower illustration of Figure 2-5 and in Figure 2-6 is set correctly. If you have an older model Cyber Series terminal with a 3-pin power jumper (upper illustration in Figure 2-5), the jumper should go on the upper two pins. If you have a Cyber Series finger geometry terminal, be sure the battery jumper on the connector board is set correctly.
If the face is separate, attach the face to the terminal base after connecting the wiring. Secure the face to the base with the key lock. When 12VDC is connected, the Cyber Series terminal will power up and display its on-line default message. The Cyber Series terminal is now ready for setup and configuration. Refer to Chapter 3, Setup, Test, Diagnostics, and Maintenance for terminal setup instructions.
Cyber Series Time and Attendance Terminals
2 - 10
Introduction
Plug the primary of the power pack assembly to a conventional wall outlet.
Page 32
Installation
Figure 2-5: Cyber Series Terminal Connections and Jumpers EARTH GND
THREE-PIN POWER JUMPER +12V
PLACE JUMPER ON UPPER TWO PINS IF USING +12VDC POWER PACK DIRECT CONNECTION
GND
POWER (P7) BATTERY (P8) _ +
3 2 1
1
SERIAL (J8)
POWER
1
DIDO (J9) LINK
DIDO
BUSY
SERIAL
1
WAND ETHERNET (OPTIONAL) JTAG
ETHERNET INDICATOR LEDS (IF ETHERNET PRESENT)
WAND (J2)
1 SIO-IN (CONSULT FACTORY) 2 DIGITAL-IN 3 GND 4 +5V (CONSULT FACTORY) 5 DIGITAL-OUT 6 SIO-OUT (CONSULT FACTORY) 1 EARTH GND 2 GND 3 +5V 4 N/C 5 DATA 6 N/C
JTAG (FACTORY USE)
TWO-BOARD CYBER SERIES TERMINAL (OLD MODEL) EARTH GND
SIX-PIN POWER JUMPER +12V
STANDARD POSITION, NO MODEM
GND
POWER (P7) LINK LED
ETHERNET (OPTIONAL)
BATTERY (P8) _ +
POSITION IF MODEM INSTALLED
3 2 1
1
SERIAL (J8) POWER BATTERY
BUSY LED 1
SERIAL
DIDO (J9)
DIDO WAND
1
WAND (J2) JTAG
RS485 RS232 1 EARTH GND _ TERM REC 2 TERM REC 3 TERM TRANS TERM XMIT +_ TERM XMIT 4 TERM RTS TERM REC + 5 TERM CTS 6 PWR GND1 7 POWER (CONSULT FACTORY) 8 PWR GND2 1 SIO-IN (CONSULT FACTORY) 2 DIGITAL-IN 3 GND 4 +5V (CONSULT FACTORY) 5 DIGITAL-OUT 6 SIO-OUT (CONSULT FACTORY) 1 EARTH GND 2 GND 3 +5V 4 N/C 5 DATA 6 N/C
JTAG (FACTORY USE) SINGLE-BOARD CYBER SERIES TERMINAL
Cyber Series Time and Attendance Terminals
2 - 11
Introduction
BATTERY
RS485 RS232 1 EARTH GND _ TERM REC 2 TERM REC 3 TERM TRANS TERM XMIT +_ TERM XMIT 4 TERM RTS TERM REC + 5 TERM CTS 6 PWR GND1 7 POWER (CONSULT FACTORY) 8 PWR GND2
Page 33
Installation
Figure 2-6: Cyber Series Finger Geometry Terminal Connections
MODEM
ETHERNET
POWER BATTERY (NOT USED)
ANALOG PHONE LINE
SERIAL
DIDO
WAND PLUG IN POWER PACK (CHOOSE ONE)
NO BATT BATT
CONNECTOR BOARD
Cyber Series Time and Attendance Terminals
Introduction
FROM DIDO BOARD IN BASE
FROM BATTERY CHARGER BOARD
RIBBON CABLES FROM CAMERA
2 - 12
Page 34
Installation
Introduction
"A"
"A"
4.75" (4 3/4")
3.00"
2.37" (2 3/8")
6.00
"B"
2.37" (2 3/8")
"B"
3.28" (3 9/32")
1.47" (1 15/32")
"A"
Figure 2-7: Cyber Series Locking Base Mounting Template
Cyber Series Time and Attendance Terminals
2 - 13
Page 35
4 7/32
7 23/32
Cyber Series Gullwing Mounting Template
Figure 2-8: Cyber Series Gullwing Base Mounting Template
Page 36
Installation
0.750
0.375
0.750
6.500
0.210" HOLES, 4X
11.250
Introduction
0.375
Figure 2-9: Cyber Series NEMA 4X Enclosure Mounting Template (50% Full Size)
Figure 2-10: Cyber Series Finger Geometry Terminal Mounting Template
Cyber Series Time and Attendance Terminals
2 - 15
Page 37
6"
9/64 " 1 1/4"
Mounting Template for 2102, 3102, and CS2102 Finger Geometry Terminals
IMPORTANT!!!
8"
3/4"
2102
3102 CS2102
Terminal MUST be grounded. Refer to instructions enclosed with the ground wire inside terminal. Grounding is ESSENTIAL to proper terminal operation.
4 1/2"
45 1/4" to floor
3102 CS2102
2102