Page 68
Setup, Test, Diagnostics, and Maintenance
Verifying Installation
This section tells you how to perform a simple query and answerback sequence between a Cyber Series terminal and its host. This will verify that installation is correct. Accu-Time Systems, Inc. makes available two sample host applications: AccuComm and Accu-Engine. Your ATS representative can provide a copy. Using one of those applications, you can send a program download file to a terminal and monitor the terminal’s response.
Test Download File
Use a text editor capable of inserting control characters (000 through 03110, 000 through 1716) to create a download file containing the lines: DR00^ DM00^Test Message^10^ DD00^
The ^ symbol represents a record separator character, 3010 or 1E16. Refer to Table 2 on page xi for a further guide to control character symbols. Those commands reset the terminal, specify a message to display, terminate the download, and put the terminal online. Use AccuComm or Accu-Engine to send that download file to the terminal. The terminal should respond with a beep and the text “Test Message” should appear on the terminal display for 10 seconds.
Programming the Terminal
Cyber Series terminals recognize the Accu-Time universal command set (UCS). Those programming commands are explained in the Universal Command Set Reference Manual. For further information, refer to that manual.
Cyber Series Time and Attendance Terminals
3 - 31
Introduction
ON00^
Page 69
Setup, Test, Diagnostics, and Maintenance
The Cyber Series terminal is a low-maintenance data collection terminal. The only required procedure is periodic cleaning of the badge reader, finger sensor, or other input device.
Cleaning the Badge Reader
To clean the badge reader, swipe a cleaning card pre-moistened with isopropyl alcohol (rubbing alcohol) through the reader several times. Low usage readers should be cleaned monthly. High usage readers should be cleaned weekly.
Cleaning the Finger Sensor
ATS uses two different finger sensors in its terminals, one made by Bioscrypt and one made by Cogent. The following table identifies which type of finger sensor is used in each model of Cyber Series terminal:
Model Number of Terminal
Cleaning the Bioscrypt Finger Sensor
Bioscrypt Reader
Cogent Reader
CSS110, CSS111 CSE210, CSE211 CS1100, CS1101 CS2100, CS2101 CS3100, CS3101
CSS113, CSS114 CSE213, CSE214 CS1103, CS1104 CS2103, CS2104 CS3103, CS3104
The Bioscrypt finger sensor used in Cyber Series biometric terminals is a rugged solid-state device designed to provide years of trouble-free service. It has been laboratory-tested with over two million touches and no measurable wear. Although the sensor has few maintenance and handling requirements, a few basic precautions in caring for it will help to ensure a high level of performance over the life of the sensor. Oily deposits from fingers will accumulate on the surface of the finger sensor after repeated use. This will normally not have any effect on sensor operation, but you may want to clean the sensor from time to time for aesthetic reasons. In normal use, Accu-Time recommends cleaning the sensor once a month, or any time an oily residue is visible on the sensor surface. To clean the sensor surface, follow these steps: 1. Remove electrical power from the finger sensor by disconnecting the terminal from its power source. 2. Use a household kitchen or window cleaner such as Formula 409TM,
WindexTM, or a generic version of these cleaners. DO NOT use chlorine-based cleaners such as CloroxTM bleach, non-chlorine bleach, or chlorine-based bathroom or mildew cleaners. Chlorine-based cleaners will not necessarily affect the functionality of the fingerprint sensor, but they will discolor and could
Cyber Series Time and Attendance Terminals
3 - 32
Introduction
Maintenance
Page 70
Setup, Test, Diagnostics, and Maintenance damage the surrounding enclosure and peripheral components. DO NOT use any solvents such as acetone, MEK, TCE, paint thinner, turpentine, etc. 3. Dampen a clean cotton swab (not soaking or dripping wet) with an approved cleaner. Gently rub the sensor surface and surrounding bezel with the wet cotton swab, rotating the swab to keep exposing a clean surface to the sensor. If the sensor is very dirty, you may need to repeat the cleaning operation using a new clean swab. Do not allow cleaner to drip or run down into the enclosure. Do not use nylon brushes or scouring pads, abrasive cleaning fluids or powders, or steel wool. These items can damage the sensor. 4. After cleaning with the wet swab, gently rub the surfaces again with a clean dry cotton swab.
The border, called the drive ring, that surrounds the sensor surface is made of highconductivity silver-filled epoxy. After an extened period of use, this border may become tarnished. Although this should not affect reader performance, you may with to clean the surface for the sake of appearance. To clean this surface, perform the following steps: 1. Remove electrical power from the finger sensor by disconnecting the terminal from its power source. 2. Using a new pink rubber pencil eraser, “erase” the surface of the drive ring to remove the tarnishing. Do not rub the sensor surface with the eraser. Do not use an old eraser. 3. Brush off the eraser dust with a clean dry cotton swab or tissue. Do not remove the eraser dust with a wet or damp material. Do not scratch the sensor surface. 4. Reconnect the terminal power when cleaning is complete.
Caring for the Bioscrypt Finger Sensor
The Bioscrypt finger sensor is designed to perform well even under harsh conditions. Nevertheless, some precautions should be taken to avoid damaging the sensor: • The sensor can be damaged by a discharge of static electricity from your body. The finger sensor is typically surrounded by conductive plastic, however, which is connected to a ground plane. You should always touch the conductive plastic before touching the sensor to safely discharge any static electricity that may be present on your skin or clothing. • Do not place the finger sensor close to a heat source, such as a radiator or hot plate. The sensor can be stored in temperatures ranging from –6º C to +150º C, and can operate in temperatures ranging from 0º C to + 60º C. Cyber Series Time and Attendance Terminals
3 - 33
Introduction
5. Reconnect the terminal power when cleaning is complete.
Page 71
Setup, Test, Diagnostics, and Maintenance
In addition, the sensor should not be exposed to rain or excessive moisture. The sensor can operate within a range of 5% to 95% relative humidity (non-condensing). With the exception of the cleaners listed in the section Cleaning the Finger Sensor on page 3-32, do not put any liquids on the sensor. • Do not subject the finger sensor to heavy shocks or vibrations. • Do not allow the sensor to come in contact with metallic objects.
Clean the surface of the finger sensor with a lint-free cloth dampened with isopropyl alcohol.
Introduction
Cleaning the Cogent Finger Sensor
Cyber Series Time and Attendance Terminals
3 - 34
Page 72
Setup, Test, Diagnostics, and Maintenance
If you choose the DHCP setup option in a Cyber Series terminal see Dynamic DHCP on page 3-17), you need to configure a vender option code (default is 128) on your DHCP server so it will return a list of up to five IP addresses for valid host PCs to which the terminal can connect. The data type for the option code values on the server should be ip-address, in an array up to five elements long. There must be at least one valild value. If there are more than five entries, the extra entries will be ignored. Cyber Series terminals cannot resolve URLs, so these entries must be numeric IP addresses. You must also set the DHCP server so those IP addresses are always assigned to the valid host PCs.
Introduction
Setting Up the DHCP Option Code
Cyber Series Time and Attendance Terminals
3 - 35
Page 73
Setup, Test, Diagnostics, and Maintenance
Troubleshooting Guide Problem: Terminal does not power up, the display and none of the status LEDs are lit. Possible cause: No DC power applied Solution: Ensure primary side of DC power pack assembly is plugged into a live AC outlet. Ensure secondary side of DC power pack assembly is plugged into the Time and Data Collection Terminal (DCT). Solution: Test the outlet by plugging in another appliance. Solution: If all else fails, replace the power pack assembly. NOTE: If the battery backup option is installed, the terminal will operate for approximately 1.5 hours after the primary voltage source is lost. After this, the terminal will power off. The yellow low power indicator LED, located on the front of the terminal, will illuminate while operating in the battery backup mode. Problem: Yellow Low Power indicator is lit. Possible cause: Low DC power is attached. Solution: Replace 12-volt DC power pack. Problem: Terminal is not communicating with host computer. Possible cause: Terminal to Host communication cable is defective or unplugged on either end. Solution: Verify cable is tested and plugged into both ends. (Ensure cable termination guidelines and lengths are observed.) Solution: Ensure the application package is loaded and running on the host. Possible cause: Communication parameters (for example, baud rate) for the terminal do not match those of the host computer. Solution: Ensure all communication parameters on host and terminal match. Problem: Terminal does not accept badge data. Possible cause: Bar code badge is not manufactured to proper specification. Solution: Refer to vendor’s specifications for manufacturing criteria. Possible cause: Badge is being swiped in the wrong direction. Solution: Ensure media faces to the right (away from the keypad). Possible cause: Badge code format is not supported.
Cyber Series Time and Attendance Terminals
3 - 36
Introduction
Solution: Check the AC voltage.
Page 74
Setup, Test, Diagnostics, and Maintenance
Solution: Ensure badge code is among those supported. Supported codes include most standard bar code formats including UPCA, 128, 3 of 9, 2 of 5, Interleave 2 of 5 and more, as well as IATA Track I and ABA Track II magnetic stripe input (program dependent). Possible cause: Badge reader needs cleaning. Solution: Swipe a pre-moistened (isopropyl alcohol) cleaning card through the reader several times. Possible cause: Badge number does not exist in validation file. Solution: See Supervisor Problem: Terminal does not accept keypad input. Possible cause: Keyed data does not exist in validation file Solution: See Supervisor Possible cause: Keypad connector is unplugged. If the suggested solutions have been tried and the problem still exists, contact the Accu-Time Systems’ Product Service Department at (860) 870-5000 during normal working hours 9 AM to 5 PM Eastern time Monday through Friday. Prior to contacting Accu-Time, please have available the serial number and, if possible, the configuration number of the product. NOTE: The terminal has no user serviceable parts. Accu-Time terminals must be operated within the parameters included in this manual. Any operation performed contrary to these parameters will void the warranty
Cyber Series Time and Attendance Terminals
3 - 37
Introduction
Solution: Test keypad in Test Mode.
Page 75
Setup, Test, Diagnostics, and Maintenance
Ethernet Troubleshooting Guide Power-Related
Problem: The terminal display is blank (no characters or backlight). Possible cause: The primary of the power pack assembly is not plugged into an ACwall outlet, is not plugged into the terminal, or is the wrong voltage. Solution: Check the outlet, both power pack connections, and that it is a 12VDC power pack. Solution: If all else fails, replace the power pack. NOTE: If the battery backup option is installed, the terminal will operate for approximately 1.5-hours when the primary voltage source is lost. After this, the terminal will power off. The yellow indicator light, located on the front of the terminal, will illuminate prior to the terminal blanking out. Problem: The low power (yellow) indicator LED is activated.
Solution: Perform the above solution if the terminal display goes blank upon removal of the battery connector.
CommunicationRelated
Problem: The terminal is not communicating with the host. Possible cause: Communication parameters were not previously set. Solution: Place terminal in Test Mode and step through ACCU-RATE Test procedures. Your network administrator needs to provide the following: • IP address to be assigned to the terminal • IP address of the host to which the terminal can connect • Network Mask (example 255.255.255.0) • Gateway or Router address (if required) Solution: If parameters are set, place terminal in Use Mode and perform a "ping" on the terminal. Solution: Verify activity of LEDs located on the bottom of the terminal. Solution: Verify that the cable is plugged into both ends (terminal and hub) and terminated to the appropriate eight- (8) position modular connector.
Cyber Series Time and Attendance Terminals
3 - 38
Introduction
Possible cause: Outlet or power pack problem.
Page 76
Setup, Test, Diagnostics, and Maintenance
Solution: Verify that the single segment cable length is equal or less than the specified 100 meters (328 feet). The cable should also be a 10/100BASE-T category 5, twisted pair high-speed data transmission cable with both ends properly crimped. Solution: Ensure application package is loaded and running on the host. Check the Ethernet diagnostic LEDs (refer to Figure 2-5): BUSY: Terminal is BUSY processing LINK: Terminal is LINKED to host Problem: A previously working terminal now is not operational. Possible cause: Cables not plugged in or host application software not operational. Solution: Insure that all connections are made and that the host software application is functional. If possible, take a known working terminal, re-address it for this particular node and determine if the problem is related to the terminal, installation or host. Problem: Terminal sends duplicate punches.
If neither the standard nor Ethernet troubleshooting guide is of any help, please contact the Accu-Time Product Service Center, (860) 870-5000, for further assistance.
Cyber Series Time and Attendance Terminals
3 - 39
Introduction
Possible cause: This behavior will occur if the terminal is set for AppAck but the host is not. Be sure communication protocols are set correctly.