Page 77
Appendix A Proper Use of a Biometric Reader
This appendix gives guidelines for using the finger scanner on a Cyber Series biometric terminal. Proper use of the scanner will help ensure consistent and accurate finger scans. The illustrations on the next page summarize the three key steps: • TOUCH - Although the scanner is robust, it can be damaged by static electricity discharge. The bezel surrounding the reader window is made of conductive plastic. When using the scanner, touch the bezel to discharge any static electricity before touching the reader window. • SLIDE - Consistent finger placement is essential for consistent readings. The scanner bezel has a raised ridge just in front of the reader window. After touching the bezel, slide your finger forward over the raised ridge until the ridge locks into the depression formed by your first finger joint. Try to position your finger the same way each time you use the reader. • PRESS - When your finger joint is in position on the raised ridge, bend your finger slightly and press the pad of your finger down against the reader window with moderate pressure. A finger may not scan properly if it is extremely dry. If that problem occurs, it may help to rub the finger across one’s forehead or beside one’s nose to pick up a bit of natural skin oil. The finger should not be wet.
Cyber Series Time and Attendance Terminals
A-1
Page 78
Proper Use of the Finger Scanner Discharge any static electricty
Slide your finger forward until the first knuckle joint goes over the raised ridge on the front of the reader. Try to put your finger in the same position each time you use the reader.
TOUCH
ARD SLIDE FORW
PRESS DOWN Slightly bend your finger joint to press the pad of your finger down onto the reader glass with moderate pressure.
Cyber Series Time and Attendance Terminals
A-2
Page 79
Correct and Incorrect Finger Placement
Correct
Too Far Forward
Rotated
Too Far Back
Too Far to Side
Cyber Series Time and Attendance Terminals
A-3
Page 80
Cyber Series Time and Attendance Terminals
A-4