The text of a manual · part 12 of 13
Accu-Time Cyber Series Standard, Biometric, and NEMA 4X Time and Attendance Terminals, pages 81 to 86
Pages 81 to 86 of 91: Appendix B Updating the Firmware; Appendix A Proper Maintenance and Use of a Biometric Finger Geometry Reader
The original document is the PDF (952 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Time CS2100 and Accu-Time CSS110
Page 81
Appendix B
Updating Terminal Firmware
Updating the Firmware
ATS periodically releases updated firmware for Cyber Series terminals. Because the firmware is stored in the terminal’s flash memory, you can easily upgrade your Cyber Series terminal to the latest revision of the firmware. Contact your ATS representative to find out if a newer firmware revision is available for your terminal. When you call, be ready to provide the program number of the currently installed firmware. The currently installed flash program number is shown as part of the initial display screen when you first power on the terminal. See Figure 3-1 on page 3-1. ATS will send you a firmware image file. BE ABSOLUTELY CERTAIN YOU HAVE THE CORRECT FILE FOR YOUR TERMINAL! If you attempt to load an incorrect flash image into your teminal, it will become completely inoperative and will have to be returned to ATS for repair. After you receive the proper flash image, you download it to the terminal exactly as you would download any program image. For example, you can use the ATS Accu-Engine program to do the download. Create an Accu-Engine script file to do the download, specifiying the name of the flash image file and including its file type of .CFL. Using Accu-Engine, establish a communication link between the terminal and a host PC and execute the script. Accu-Engine will download the flash image to the terminal, displaying status message on the terminal’s display screen as it does so. Do not interrupt the download process! When the download is complete, the terminal will return to its initial display. Check to be sure the new program version number appears in the display.
Cyber Series Time and Attendance Terminals
B-1
Page 82
Updating Biometric Reader Firmware
If your terminal has a biometric finge scan reader, you can update the firmware that controls the reader, just as you can update the terminal’s firmware. Because the firmware is stored in the biometric reader’s flash memory, you can easily upgrade your biometric reader to the latest revision of the firmware. (This does not apply to finger geometry readers.) Contact your ATS representative to find out if a newer firmware revision is available for your biometric reader. When you call, be ready to provide the program number of the reader’s currently installed firmware. You can get the reader’s program number by using the terminal’s Diagnostics mode, as described in the section Diagnostics Mode on page 3-22, and looking at the FPR Identify Image screen. (Depending on the particular type of reader installed, the screen may read FPR Verify Image.) ATS will send you a firmware image file. (Occasionally, there may be multiple files.) Verify that you have the proper flash image for your reader. After you receive the proper flash image, you download it to the reader exactly as you would download any program image to the terminal. For example, you can use the ATS Accu-Engine program to do the download. Create an Accu-Engine script file to do the download, specifiying the name of the flash image file and including its file type of .FFL. Using Accu-Engine, establish a communication link between the terminal and a host PC and execute the script. If you received multiple files, be sure to download them in the correct order. Accu-Engine will download the flash image to the reader. Do not interrupt the download process! When the download is complete, the terminal will return to its initial display. Go to Diagnostics mode and check to be sure the new reader program version number appears in the display.
Cyber Series Time and Attendance Terminals
B-2
Page 83
Appendix A Proper Maintenance and Use of a Biometric Finger Geometry Reader
This appendix gives guidelines for maintaining and using the finger geometry reader on a Cyber Series biometric finger geometry terminal. Proper maintenance and use of the reader will help ensure consistent and accurate results.
Maintenance The Cyber Series finger geometry terminal is a nearly maintenance-free data collection device. The only required procedure is periodic cleaning of the badge reader, biometrics finger platen, mirror, and lenses.
Badge Reader To clean the badge reader, swipe a pre-moistened (isopropyl alcohol) cleaning card through the bar code or magnetic reader several times. Low usage readers should be cleaned monthly. High usage readers should be cleaned weekly.
Finger Platen Remove any finger marks and dust from the finger platen (the surface the fingers are placed on) with a soft lintfree cloth. Wet the cloth with a mild dishwashing liquid or comparable cleaneing solution and wipe the platen surfaces gently. Polish using a dry soft cloth. You should clean the platen about twice a month, or whenever there is a visible build-up of dust and dirt. Avoid the following when cleaning the platen assembly: • Scraping or scratching the surfaces.
Cyber Series Time and Attendance Terminals
A-1
Page 84
• Using cleaners containing ammoniating abrasive cleaners or steel wool, etc. • Spraying cleaner directly onto the platen. • Using highly alkaline cleaners. • Using gasoline (petrol), benzene, acetone, or similarly aggressive solvents likely to attack the plastic surfaces.
Lenses and Mirror The mirror that is visible in the back of the camera as well as two lenses that are hidden from view should be cleaned periodically to ensure proper operation of the terminal. Use the special cleaning brush supplied with the terminal. To clean lens #1, insert the cleaning brush into the front of the camera near the left side. move it up, then pull it gently forward and down until the small hooked brush stops against the lens plate as shown in the cross-section view of Figure A-1 on page A-3. Hold the brush handle horizontally and gently move the brush left and right across the lens to clean it. The brush will be able to move slightly less than halfway across the width of the camera before it is stopped by the imaging block, and shown in the front view. To clean lens #2, insert the cleaning brush on the right-hand side of the camera opening and repeat the operation. To clean the mirror, use the long cleaning brush on the end of the handle to dust the mirror. This will remove any dust. If there are smudges on the mirror, wet a soft lint-free cloth with a mild dishwashing liquid or comparable cleaning solution and wipe the mirror surface gently. Polish using a dry soft cloth. You should clean the mirror whenever there is a visible build-up of dust and dirt.
Cyber Series Time and Attendance Terminals
A-2
Page 85
Figure A-1: Cleaning CS2102 Lenses IMAGING BLOCK MIRROR
LENS #1
LENS #2
CLEANING BRUSH
Handle is horizontal for proper cleaning
CROSS SECTION
Cyber Series Time and Attendance Terminals
FRONT VIEW
A-3
Page 86
Correct and Incorrect Finger Placement Correct Finger Placement: • • •
Place the index and middle fingers (recommended) flat on the platen, straddling and touching the pegs. Fold the thumb around the third and fourth fingers. The junction between the two fingers should be touching the smaller front peg.
Too Far In: •
If the top LED is on, the fingers are pushed too far in. Pull back a bit.
Too Far Out: •
If the bottom center LED is on, the fingers are not inserted far enough. Slide them in a bit more.
Left Not Touching: •
If the left center LED is on, the left finger is not touching the pegs.
Right Not Touching: •
If the right center LED is on, the right finger is not touching the pegs.
Angled Left: : •
If the lower left LED is on, the fingers are angled from left to right. Ensure that the fingers enter the reader directly from the front.
Angled Right: •
If the lower right LED is on, the fingers are angled from right to left. Ensure that the fingers enter the reader directly from the front.
Cyber Series Time and Attendance Terminals
A-4