Page 41
CONNECTING YOUR MODEL 20 TO AN EXTERNAL DEVICE
3-5
RS422 (POINT-TO-POINT) The Model 20 does not communicate using current loop directly. You must set up the Model 20 to communicate using RS-422 and use the Small Scanner Interface box to convert it to current loop.
Use the following drawing as a guide when you want to connect your Model 20 to a device that is using RS422 serial communication: NOTE: All connectors are shown from the soldering side. 220 Termination
Model 20 (P1) 1
15
6
1 6 8 7 9
220 Termination
HOST
GND SD+ SDRD+ RD-
S. GND RD+ RDSD+ SD-
NOTE: Termination resistors may be placed inside the connector strain relief. The termination resistor value is 220 OHM 1/4 watt. With RS-422, the receive lines on both sides must be terminated. CABLE TYPE: ALPHA #5473C (OR EQUIVALENT).
RS485 MULTIDROP Use the following drawing as a guide when you want to connect your Model 20 to a device that is using RS485 multidrop serial communication: NOTE: All connectors are shown from the soldering side. 220 Termination
Model 20 (P1)
(Polling Required)
HOST
1
6
15
End Of The Line
1 6 8
GND SD+/RD+ SD-/RD-
1 6 8
GND SD+/RD+ SD-/RD-
1 6 8
GND
S. GND S D + / R D + End Of The Line SD-/RD-
SD+/RD+ SD-/RD-
220 Termination
NOTE: RS485 allows for communication across the same lines Termination resistors can be placed inside the connector strain relief. The termination resistor value is 220 OHM 1/4 watt. The transmit-receive lines on both sides must be terminated.
Cable type: Alpha #5473C (or equivalent)
You must enable communication types using the software. Refer to your AccuSetup Suite Small Scanner Module Programming Manual.
Solutions with Vision
Page 42
3-6
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
CONNECTING YOUR MODEL 20 TO A PC Accu-Sort recommends that you purchase the programming kit for your Model 20. This kit provides you with the cables that you need to connect your AccuSort device to a PC. If you would like to purchase the programming kit, call the Accu-Sort Customer Service Department at toll free 1-800-BAR-CODE with the following information: Part Name
Part Number
Model 20 Programming Kit-110VAC Model 20 Programming Kit-220VAC
1000017369 1000017371
Model 20 Programming Kit
To connect your Model 20 to most PCs using the programming kit: 1. Plug in the 15-pin connector on the programming kit cable labeled P1 to the 15-pin connector on the back of your Model 20. 2. Plug in the 9-pin connector end of your programming kit cable labeled PC to a 9-pin serial port on your PC. 3. Use a small standard slot-head screwdriver to tighten the screws on the strain reliefs at both ends. 4. Plug in the programming kit power supply in the appropriate wall socket. Connecting to a PC without the Programming Kit
If you choose not to purchase the Model 20 Programming Kit, you need to make your own cables. The following diagrams show typical RS232 communication cable pin connections from your PC to your Model 20 with connector and cable specifications. Specifications 15-pin connector 9-pin connector Cable 15-pin & 9-pin strain relief
Assmann part # A-HDF15LL-T or equivalent CINCH part # DEM-9S or equivalent Alpha part # 5473C, Manhattan Part # M3264, or equivalent Northern Technologies part # C88300004 or equivalent
If your PC has a 25 pin serial connector, you can use any standard 9 pin to 25 pin mating connector adapter to make the connection.
Accu-Sort Systems
Page 43
CONNECTING YOUR MODEL 20 TO AN EXTERNAL DEVICE
3-7
NOTE: All connectors are shown from the soldering side. Standard 9 Pin PC Connector
9 Pin Female "D"
15 Pin Female "D" 1
1
9
25 Pin Female "D"
Standard 25 Pin PC Connector
15
15 Pin Female "D"
TXD
1
6
Model 20
PC
1
RXD
25
PC
Model 20
6
15
Model 20 to PC Connections If your PC has a 25 pin serial connector, you can use any standard 9 pin to 25 pin mating connector adapter to make the connection.
Solutions with Vision
Page 44
3-8
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
CONNECTING YOUR MODEL 20 TO A TERMINAL If you are using a terminal to program your Model 20, you need to make your own cables. The following diagrams below show typical RS232 communication cable pin connections from your terminal to your Model 20 and connector and cable specifications. These pin connections are correct for most Terminals. Your terminal may be different. Before you begin making your cable, check your terminal documentation to make sure these pin connections are accurate. Specifications 15-pin connector 25 pin connector Cable 25 pin strain relief 15-pin strain relief
Assmann part # 1000012239 or equivalent CINCH part # DEM-25P or equivalent Alpha part # 1000009323, Manhattan Part # 1000017397, or equivalent Northern Technologies part # 1000014297 or equivalent Northern Technologies part # 1000014298 or equivalent
NOTE: All connectors are shown from the soldering side. Standard 25 Pin CRT Connector
25 Pin Male "D"
15 PIn Female "D"
25 1
1
CRT
6 Model 20
Terminal to Accu-Sort Device Connections
Accu-Sort Systems
15
Page 45
CONNECTING YOUR MODEL 20 TO AN EXTERNAL DEVICE
3-9
SUPPLYING POWER TO YOUR MODEL 20 You must supply power to the Model 20 through the 15 pin connector at the rear of the unit. You can supply power using one of the following three methods: using the small scanner interface box, using one of the Accu-Sort local power supplies, or wiring power directly into the Model 20 using one of your own methods. The Model 20 must meet the following three requirements regardless of the method that you use to supply power: • +5VDC must be supplied (range between +4.85VDC and +5.25VDC @ 500 mA, maximum ripple 100mV) • Ground must be supplied • Metal shell of connector must be grounded
Make sure the metal shell of the connector is grounded. This provides chassis ground to the unit case, and is necessary for proper operation. USING THE SMALL SCANNER INTERFACE BOX FOR POWER To use the small scanner interface box as a power source for the Model 20, you can use the Accu-Sort Interconnect Cable as shown below. This method of supplying power to the Model 20 complies with all the requirements mentioned above. This cable has two 15 pin "D" connectors. Connect one end to the 15 pin "D" male connector on the rear of the Model 20, and connect the other end to the 15 pin "D" female connector labelled SCANNER J1 on the interface box. The small scanner interface box provides the Model 20 with operational power.
Interconnect Cable
Solutions with Vision
Page 46
3-10
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
USING ACCU-SORT’S LOCAL POWER SUPPLY FOR POWER You can use the Accu-Sort 110V AC or the 220V AC local power supply that comes with flying leads to supply power to the Model 20 15 pin "D" connector. These power supplies are shown below:
110 VAC Local Power Supply connects to Model 20 only
220 VAC Local Power Supply connects to Model 20 only
These power supplies do not provide power to the small scanner interface box. Refer to Chapter Four of this manual for Interface Box power requirements.
If you use one of these power supplies, you need to connect the leads to the Model 20 15 Pin "D" connector. You need to comply with the Model 20 power requirements mentioned on the previous page, to ensure proper operation. Use the following information to make these connections: 110V and 220V Power Supply Striped Wire - ground Non-striped Wire - +5V
Model 20 Pin # Pin 11 Pin 15
If no ground is available from another source, you can split the ground wire from the local power supply. This grounds the shell/case. When you are using Accu-Sort’s local power supply, make sure the metal shell of the connector is grounded.
Accu-Sort Systems
Page 47
CONNECTING YOUR MODEL 20 TO AN EXTERNAL DEVICE
3-11
WIRING OTHER SOURCES OF POWER DIRECTLY To supply power to the Model 20 15 pin "D" connector, you can use many other sources than those previously mentioned. You must comply with the Model 20 power requirements, mentioned in the beginning of this section, to ensure proper operation. When you are providing power to the Model 20 directly from another source, make sure the metal shell of the connector is grounded.
Isolation may be required, if the chassis is used as a conductive plate.
The drawings below show alternate ways of wiring power into the Model 20: Model 20 1
Power Source 1
GND
15 +5VDC 6
15
Power Source
Model 20 1
1
GND
15 +5VDC 6
15
Alternative Wiring Methods for Supplying Power to the Model 20
Solutions with Vision
Page 48
3-12
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
SUPPLYING A TRIGGER INPUT TO YOUR MODEL 20 A triggering device can be used to supply an electronic signal or pulse to inform the scanner of the presence of an object within its reading zone. If you are not using the Small Scanner Interface Box and you need a connection for trigger input, you can wire a triggering device directly to the Model 20 15-pin connector using pins 11 and 13. The drawing below shows two of the most common ways to wire a triggering device directly to your Model 20.
Normally High
74XX
DEM-9P J1 J1 1 1 11 11 13 13 15 15
Note: Connector is shown from the soldering side.
GND GND Trigger +5V
20 scanner represents approximately 1 TTL load
Model 20 15 pin female "D"
Closed = Triggered
DEM-9P J1 J1 1 1 11 11 13 13 15 15
GND GND Trigger +5V
Two Different Ways to Wire a Triggering Device to Your Model 20 (Top TTL Method, Bottom-Dry Contact Method)
Accu-Sort Systems
Page 49
CONNECTING YOUR MODEL 20 TO AN EXTERNAL DEVICE
3-13
USING MODEL 20 PARALLEL OUTPUTS The Model 20 has two parallel outputs; NVC/NO MATCH and GO/MATCH. These output timers are activated or deactivated from pin 4 and pin 5 respectively on the Model 20 15-pin connector. Both of these outputs are controlled by software. (Refer to your Accu-Setup Small Scanner Module Programming Manual) You can use these outputs to have a beeper sound when you receive a no read or no match (when used as a verifier), or you could have a light turn on every time there is a go (good read) or match (when used as a verifier). There are many other uses for these outputs. When you connect these pins to the small scanner interface box, they control the relays in the box. HOW THE OUTPUTS WORK The Go/Match (out 1) output can not be enabled when RTS/CTS protocol is enabled. (Refer to your Accu-Setup Suite Small Scanner Module Programming Manual.)
The names of the two outputs directly reflect their purpose. The NVC/NO MATCH output changes its electrical state dependent on receiving a no read or a no match (while in verifier mode). The GO/MATCH output timer changes its electrical state dependent on receiving a good bar code or a match (while in verifier mode). These outputs are open collectors. When the signal is low, it causes the state of the relay to remain unchanged. When the signal is high, it causes the state of the output to change. For example, if you set the NVC/NO MATCH timer for 150 milliseconds, every time the scanner sees a non valid bar code the NVC/NO MATCH timer signal remains high until that 150 millisecond time period is complete.
Solutions with Vision
Page 50
3-14
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
PARALLEL OUTPUT CONNECTIONS The following diagrams show the proper connections that you need to ensure that the outputs function properly. If you use the interface cable to connect the Model 20 to the Small Scanner Interface Box, you do not need to make any other connections. Model 20 1
1
GND
4
OUT 0 -
15
6
Load +
+
Model 20 1
1
GND
5
OUT 1 -
15
6
Load +
+
Output Connections
The table below defines some basic terminology. The drawing below shows the schematic of the output circuitry: Software
Model 20
Interface Box
NVC/No Match = Go/Match =
OUT 0 = OUT 1 =
Relay 1 Relay 2
+5V
Model 20 OUT 0
1
10K
820 OHM
10K
Pins
2 TTL Outputs
6
15
(Optional CTS)
0 4 OUT OUT 1/CTS 5 3
3 to 7 KOHM RS232 IC
2
1
OUT 1 820 OHM
Model 20 Output Circuitry For true TTL compatible output from pin 5, an external 750 OHM pullup resistor is required between pin 5 and pin 14.
Accu-Sort Systems