Page 31
WHAT TO DO AFTER RECEIVING YOUR MODEL 20
2-5
LADDER MOUNTING BRACKET The ladder mounting bracket is designed to hold the Model 20 in a position so the scan line is perpendicular to the mounting surface. The bracket fits around the Model 20, but is not directly secured to the Model 20. Flanges on the bracket provide oblong slots that are designed for #6 mounting screws on either side of the Model 20. Mounting screws need to be located 2.25" (5.7 cm) apart. To mount the Model 20: 1. Place the bracket around the Model 20 so the support of the bracket rests on one of the sides of the Model 20, as shown below. 2. Place the mounting bracket, with the Model 20 clamped inside, against the mounting surface. 3. Insert and tighten the mounting screws in the oblong slots on the bracket. This ensures the Model 20 is secured within the bracket against the mounting surface.
Mounting the Model 20 Using the Ladder Mounting Bracket
Solutions with Vision
Page 32
2-6
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
PICKET FENCE MOUNTING BRACKET The picket fence mounting bracket is designed to hold the Model 20 in a position so the scan line is parallel to the mounting surface. The bracket fits around the Model 20, but is not directly secured to the Model 20. Flanges on the bracket provide oval slots that are designed for #6 mounting screws on either side of the Model 20. Mounting screws need to be located 3" (7.62 cm) apart. To mount the Model 20: 1. Place the bracket around the Model 20 so the backing of the bracket rests on top of the Model 20, as shown below. 2. Place the mounting bracket, with the Model 20 clamped inside, against the mounting surface. 3. Insert and tighten the mounting screws in the oblong slots on the bracket. This ensures the Model 20 is secured within the bracket against the mounting surface.
Mounting the Model 20 Using the Picket Fence Mounting Bracket
Accu-Sort Systems
Page 33
WHAT TO DO AFTER RECEIVING YOUR MODEL 20
2-7
CRADLE MOUNTING BRACKET There is one cradle mounting bracket, one 2-1/8" #6-32 round spacer, two 3/8" #6-32 socket head cap screws, two #6 flat washers, and two #6 split lockwashers included with this assembly. The cradle-mounting bracket is designed to hold the Model 20 in a position so the scan line is parallel to the mounting surface. Four #6-32 pem nuts are provided on the bottom of the bracket. The top edges on both sides of the cradle are bent at a 90-degree angle. This results in two flanges that fit into the slots on the sides of the Model 20. There are six slots on each side of the Model 20. Different sets of slots can be used with the following results: Bottom Slots Four up from bottom
Overall height (bracket and Model 20) 2.75" Overall height (bracket and Model 20) 2.05"
Mounting the Model 20 Using the Cradle Bracket
Solutions with Vision
Page 34
2-8
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
MOUNTING THE PHOTOEYE This section describes how to mount your photoeye to the photoeye mounting bracket. Photoeyes work by bouncing a light beam off a reflector and detecting when something breaks the path of light. In order for your photoeyes to work properly, you must make sure the following things are done: • The photoeye must have a reflector mounted directly opposite it on the other side of the conveyor. • The photoeye must be mounted so the light exit window is perpendicular to the conveyor, facing the reflector. • The reflector must be mounted perpendicular to the conveyor, facing the photoeye. Use the following drawings to help you mount your photoeye. The tables provide information pertaining to each item number in the drawing.
Photoeye Mounting Diagram
Use the following table to match item numbers with the photoeye mounting diagram above:
Accu-Sort Systems
Quantity Required
Description
Part Number
Item Number
1 1 1 1 1 1 2 2 4 2 1
#8-32 Nut #8 Internal Tooth Lock Washer #8 Flat Washer 3” Reflector 8-32 2” Machined Pan HD Model 30 PE Mtg. Bracket #6-32 Nut #6 Internal Tooth Lock Washer #6 Flat Washer 6-32 2” Machined Pan HD Polarized Photoeye
1000018466 1000016778 1000022114 1000013792 1000010689 1000011711 1000018459 1000016776 1000022111 1000009740 1000013425
11 10 9 8 7 6 5 4 3 2 1
Page 35
WHAT TO DO AFTER RECEIVING YOUR MODEL 20
2-9
Photoeye Mounting Diagram
Use the following table to match item numbers with the photoeye mounting diagram above: Quantity Required
Description
Part Number
Item Number
1 2 4 2 2 1 1 1 1 1 1 2 2
Polarized Photoeye 1/4-20 x 2" Machined Pan HD 1/4-20 Flat Washer 1/4-20 Internal Tooth Lock Washer 1/4-20 Nut Photoeye Mounting Bracket 8-32 x 2" Machined Pan HD 3" Reflector #8 Flat Washer #8 Internal Tooth Lock Washer #8-32 Nut M18 Spring Lock Washer M18 Nut
1000013425
1 2 3 4 5 6 7 8 9 10 11 12 13
1000022104 1000016772 1000018475 1000010689 1000013792 1000022114 1000016778 1000018466
Solutions with Vision
Page 36
2-10
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
SETTING UP YOUR MODEL 20 Follow the steps below to set up your Model 20 Scanning System: 1. Remove all materials from the box. 2. Check the materials against the packing list and make sure everything is there. 3. Make sure none of the parts are broken. 4. Make all the appropriate connections to your Model 20 as explained in Chapter Three. 5. If you need to make any programming changes to your Model 20, connect your Model 20 to a PC or TERMINAL as described in Chapter Three, and refer to your Accu-Setup Small Scanner Module Programming Manual. 6. Mount your Model 20 as described earlier in this chapter. 7. Begin reading your bar codes. If you have any problems or questions concerning setting up your Model 20, contact Accu-Sort immediately and refer to the Customer Service Section of this manual.
Accu-Sort Systems
Page 37
Chapter Three Connecting Your Model 20 to an External Device
3Heading 2
Chapter Three
Contents
CONNECTING YOUR MODEL 20 TO THE INTERFACE BOX ............................. 3-3 IF THE INTERCONNECT CABLE IS NOT AVAILABLE................................... 3-3 CONNECTING YOUR MODEL 20 TO OTHER EXTERNAL DEVICES .................. 3-4 RS232 WITH NO HANDSHAKING ............................................................ 3-4 RS422 (POINT-TO-POINT)...................................................................... 3-5 RS485 MULTIDROP .............................................................................. 3-5 CONNECTING YOUR MODEL 20 TO A PC ................................................ 3-6 CONNECTING YOUR MODEL 20 TO A TERMINAL ...................................... 3-8 SUPPLYING POWER TO YOUR MODEL 20 ................................................... 3-9 USING THE SMALL SCANNER INTERFACE BOX FOR POWER ..................... 3-9 USING ACCU-SORT’S LOCAL POWER SUPPLY FOR POWER ................... 3-10 WIRING OTHER SOURCES OF POWER DIRECTLY ................................... 3-11 SUPPLYING A TRIGGER INPUT TO YOUR MODEL 20................................... 3-12 USING MODEL 20 PARALLEL OUTPUTS ................................................... 3-13 HOW THE OUTPUTS WORK .................................................................. 3-13 PARALLEL OUTPUT CONNECTIONS ...................................................... 3-14
Page 38
3-2
Accu-Sort Systems
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
Page 39
CONNECTING YOUR MODEL 20 TO AN EXTERNAL DEVICE
3-3
CONNECTING YOUR MODEL 20 TO THE INTERFACE BOX When you connect your Model 20 to the Accu-Sort Small Scanner Interface Box, it is recommended that you use the interconnect cable provided with your interface box, as shown below:
Interconnect Cable
This cable has two 15-pin "D" connectors. Connect the female end of the cable to the 15-pin "D" male connector on the rear of the Model 20, and tighten the screws with a small flat-head screwdriver. Connect the other end of the cable to the 15-pin "D" female connector labeled SCANNER J1 on the interface box, and tighten the screws with a small flat-head screwdriver. The small scanner interface box provides the Model 20 with operational power. IF THE INTERCONNECT CABLE IS NOT AVAILABLE If you do not have the interconnect cable, you need to create one. The following drawing shows the pin connections for the 15-pin "D" male connector on the Model 20 and the 15-pin "D" female connector on the interface box. The maximum length of this cable is 30 feet. Note: Connectors are shown from the soldering side The shield is electrically connected to both cable shells.
Interface Box End of Cable (15 pin "D" male)
Model 20 End of Cable (15 pin female "D")
Pinouts for the Connections Between the Interface Box and the Model 20
Solutions with Vision
Page 40
3-4
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
CONNECTING YOUR MODEL 20 TO OTHER EXTERNAL DEVICES The Model 20 is versatile when you need to connect to other devices. The drawings below shows all the pin connections for Model 20 when using serial communications. If you need to create your own cables to wire your Model 20 to another device, use these drawings as a guide. It is very important that you make the proper pin connections. Below is a list of terms used in these drawings: GNDTXD CTSRDSD-
Ground Transmit Data(RS232) Clear To Send (RS232) Received Data (RS422) Inverting Line (RS485) Send Data (RS422)
RXD RTS RD+ SD+
Receive Data (RS232) Request To Send (RS232) Receive Data (RS422) Non-inverting Line (RS485) Send Data (RS422)
Be careful when you wire your own cable for the Model 20. You must make sure the Model 20 receives only 5 volts on pins 14 and 15.
You must enable communication types using the software. Refer to your AccuSetup Suite Small Scanner Module Programming Manual.
RS232 WITH NO HANDSHAKING Use the following drawing as a guide when you want to connect your Model 20 to a device that is using RS232 communicationwith no handshaking: NOTE: All connectors are shown from the soldering side.
HOST
Model 20 1
6
15
1 GND 2 TXD 3 RXD 11 GND 15 +5VDC
S. GND RXD TXD
Recommended Cable Type: ALPHA # 5473C or Equivalent Maximum Cable Length: 50 Feet
Accu-Sort Systems