The text of a manual · part 3 of 10
Model 20 Series II Bar Code Scanner Operations and Maintenance Manual, pages 21 to 30
Pages 21 to 30 of 98
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort Model 20
Page 21
GETTING STARTED WITH YOUR MODEL 20
1-5
DECODING BAR CODES The Model 20 scans a bar code, turns the reflected light into electronic signals and then amplifies the signals. It then converts the analog signal to digital pulses. The Model 20 is designed with a powerful RISC (Reduced Instruction Set Computer) processor. The RISC processor determines the width of each bar and space based on the time it took the laser to sweep across each of the elements in the bar code. The Model 20 transmits the decoded bar code information to a CRT or host computer.
Solutions with Vision
Page 22
1-6
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
HOW YOUR MODEL 20 SCANNING SYSTEM WORKS As soon as you set up and install your Model 20 as discussed in the remaining chapters of this manual, it is ready to read bar codes. The Model 20 has one multi-color LED indicator at the rear of the unit that provides you with operational information. The location of this LED is shown in the following drawing. The LED provides status on power (idle), trigger (carton presence), good read, no read or non-valid code (NVC), and failure. The following are descriptions of each LED. LED ACTION
STATUS
Blinking Yellow
Idle
Solid Yellow
Trigger
Green for ½ second Solid red for ½ second Flashes in red, yellow, green sequence Solid red for an extended period of time or blinking red
Good Read No Read Confirming Setup Mode Failure
DESCRIPTION Model 20 has power, is not triggered, and is functioning normally Model 20 laser is on, and either the trigger input is active or the unit is in continuous read mode Model 20 has successfully decoded a bar code Model 20 was not successful in decoding a bar code, or a non valid bar code was detected Model 20 is in setup mode Model 20 has detected a malfunction or is not functioning up to specifications (in either of these cases, contact Accu-Sort)
For additional information see the Problem/Solution list in Chapter 4 (Troubleshooting).
Model 20 Status LED Location
Accu-Sort Systems
Page 23
GETTING STARTED WITH YOUR MODEL 20
1-7
EXAMPLES OF LED FUNCTIONALITY The following are two scenarios of how the Model 20 Status LED works: When your Model 20 is programmed for Hardware or Serially Controlled Trigger (Refer to your Accu-Setup Suite Small Scanner Module Programming Manual), the following sequence of events should occur: 1. When the Model 20 is supplied with power, and nothing triggers the unit, the status LED blinks yellow. 2. When the trigger signal is activated (example; a box blocks the photoeye), the status LED turns to solid yellow for the amount of time the box blocks the triggering device. Solid yellow always indicates that the laser is on.
Then: • the status LED changes to green for 1/2 second if the Model 20 successfully decodes the bar code -OR• the status LED changes to red for 1/2 second if the Model 20 does not successfully decode the bar code 3. The status LED changes back to blinking yellow until the trigger signal (could be a serial character or hardware transition) is activated again. When your Model 20 is programmed for Continuous Read (refer to your AccuSetup Suite Small Scanner Module Programming Manual), the following sequence of events should occur: The Model 20 ignores any trigger input, hardware or serial. 1. When the Model 20 is supplied with power, the status LED blinks yellow for about five seconds, then it turns solid yellow, indicating read mode. 2. The status LED changes to green for 1/2 second every time the Model 20 successfully decodes the bar code. 3. The status LED then changes back to yellow. With this scenario, the status LED never turns red, because it does not know when something passes in front of the Model 20.
Solutions with Vision
Page 24
1-8
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
Enclosed in plastic on the outside of one of your boxes is a packing slip. The packing slip lists the parts of your order. As soon as you open the box(es), check the equipment against the packing slip to ensure you received everything you ordered. If any equipment is missing or has been damaged during shipment, contact Accu-Sort immediately at 1-800-BARCODE (refer to Customer Service). The Model 20 packaging was specifically designed to protect the unit during shipment. Do not throw it away. Save all the packaging materials for possible future use.
Depending upon your needs, you may have one or more of the pieces of equipment shown in the following table:
Accu-Sort Systems
Page 25
GETTING STARTED WITH YOUR MODEL 20
Part
1-9
DRAWINGS ARE NOT TO SCALE Part Description Number 1000017344 1000017345 1000017346
Model 20 Custom Assembly Model 20 Custom 1 @ 10 Raster Assembly Model 20 Custom .5 @ 10 Raster Assembly OTS Distributor Units 1000025478 Model 20, Standard, Linear Decoding, 12 Sided Mirror 1000025479 Model 20, Standard, DRX Decoding, 12 Sided Mirror 1000025480 Model 20, Standard, Linear Decoding, .5@10 Raster 1000025481 Model 20, High Density, Linear Decoding, 12 Sided Wheel 1000025482 Model 20, High Density, DRX Decoding, 12 Sided Wheel 1000025483 Model 20, High Density, Linear Decoding, .5@10 Raster 1000025484 Model 20, High Speed, Linear Decoding, 12 Sided Wheel 1000025485 Model 20, High Speed, DRX Decoding, 12 Sided Wheel 1000025486 Model 20, High Speed, Linear Decoding, .5@10 Raster 1000017362 Small Scanner Interface without relays 1000017365 Small Scanner Interface with relays 1000014575 Interconnect Cable The Small Scanner Interface connects to the Model 20 to provide a regulated 5 VDC. The Interface also separates the power input, communication port and hardware trigger input into three discrete connectors, making it easy to use the Model 20 with existing equipment without having to wire these lines directly into the Model 20. Use the interconnect cable to connect the interface box to the Model 20. 1000020527 Photoeye This is a photo-electric eye that sends a signal to the Model 20 when something blocks its path of light. Photoeyes provide one way to trigger the Model 20 when an object arrives and when an object leaves the scanner.
1000022163 110V AC Power Supply, connects to interface box only 1000017359 110V AC Local Power Supply, connects to Model 20 only 1000015618 220V AC Power Supply, connects to interface box only 1000017360 220V AC Local Power Supply, connects to Model 20 only 1000017384 Mounting Clips 1000017383 Ladder Mounting Bracket 1000017382 Picket Fence Mounting Bracket 1000017379 Mounting Plate 1000017380 Cradle Mounting Bracket Five different mounting options are offered. All of the options depend on the type of application they are to be used in. 1000017381 110V AC Model 20 Programming Kit 1000017382 220V AC Model 20 Programming Kit The programming kit connects the Model 20 to a standard 9 pin serial port on the back of a personal computer when setting-up the Model 20 software. The PC setup program is called Accu-Setup. Refer to the Accu-Setup Suite Small Scanner Module Programming Manual for details about programming the Model 20. This kit can be used to provide only power and RS232 communications, if no other signals are to be used in the application.
Parts Table Be careful when making any electrical connections. Electric shock is possible when making any contact with electricity. Do not turn on the system until all components are properly cabled and grounded with three-conductor AC power cords. Do not use a two-prong adapter. Do not use an extension cord to defeat the ground.
Solutions with Vision
Page 26
1-10
Accu-Sort Systems
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
Page 27
Chapter Two What To Do After Receiving Your Model 20
2Heading 2
Chapter Two
Contents
MOUNTING YOUR MODEL 20 .................................................................... 2-3 CLIPS .................................................................................................. 2-3 MOUNTING PLATE ................................................................................ 2-4 LADDER MOUNTING BRACKET .............................................................. 2-5 PICKET FENCE MOUNTING BRACKET .................................................... 2-6 CRADLE MOUNTING BRACKET .............................................................. 2-7 MOUNTING THE PHOTOEYE ....................................................................... 2-8 SETTING UP YOUR MODEL 20 ................................................................ 2-10
Page 28
2-2
Accu-Sort Systems
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
Page 29
WHAT TO DO AFTER RECEIVING YOUR MODEL 20
2-3
MOUNTING YOUR MODEL 20 When you mount your Model 20, make sure there is enough space around the unit for the connections to the accessories needed for your application. There must also be enough room to allow the Model 20 and its equipment to stay cool. The minimum space requirements for the Model 20 are as follows: Minimum Space Requirements for Mounting Overhead Back Sides Front
Enough room for air flow 2.25" (5.7 cm) for connections Enough room for air flow No obstructions between the scanner and the bar code to be scanned during the read cycle
There are many different ways to mount the Model 20. You can purchase the following five pieces of equipment from Accu-Sort to mount the Model 20: CLIPS There are two mounting clips designed to hold the Model 20 in a position so the scan line is parallel to the mounting surface. Each clip has an oblong slot designed for a #6 mounting screw. The mounting screws are to be located 2.9" (7.37 cm) apart. Insert the mounting clips into the grooves on the sides of the Model 20, as shown below. You can use any type of fasteners with these mounting brackets, as long as they are compatible with the mounting surface.
To mount the Model 20: 1. Fasten one clip to the mounting surface. 2. Slide the clip into one of the grooves on the side of the Model 20. 3. Place the remaining clip in the groove on the same level on the other side of the Model 20. 4. Fasten the remaining clip to the mounting surface. This ensures a tight mount so the Model 20 does not have any room for movement during operation.
Mounting the Model 20 Using Mounting Clips
Solutions with Vision
Page 30
2-4
MODEL 20 OPERATIONS AND MAINTENANCE MANUAL
MOUNTING PLATE There is one mounting plate, one mounting clip, one #6-32 nut, and one #6 internal tooth lockwasher included with this assembly. The mounting plate is designed to hold the Model 20 in position so the scan line is parallel to the mounting surface. The plate is rectangular with an oval slot near corners. The slots are designed for #6 mounting screws. To mount the Model 20: 1. Fasten the plate to the mounting surface. 2. The plate has one fixed retaining clip, one #6-32 stud and one #6 nut that holds the adjustable clip. Place the Model 20 in position so the slot on the side of the housing is engaged by the fixed clip. 3. Move the adjustable clip towards the Model 20 until it engages the other slot of the Model 20 housing. 4. Tighten the nut on the stud to secure the Model 20. This ensures a tight mount so the Model 20 does not have any room for movement during operation, and it also allows you to remove the Model 20 and replace it with the use of only one nut.
Mounting the Model 20 Using the Mounting Plate
Accu-Sort Systems