Page 51

Chapter Four Maintaining and Troubleshooting Your Model 20

4Heading 2

Chapter Four

Contents

INTRODUCTION.......................................................................................... 4-3 CLEANING PROCEDURE............................................................................. 4-3 TROUBLESHOOTING YOUR MODEL 20........................................................ 4-4 PROBLEM/SOLUTION TABLE .................................................................. 4-5

Page 52

4-2

Accu-Sort Systems

MODEL 20 OPERATIONS AND MAINTENANCE MANUAL

Page 53

MAINTAINING AND TROUBLESHOOTING YOUR MODEL 20

4-3

INTRODUCTION The Model 20 hardware was specifically designed for the tough industrial environment. The unit does not need anything more than some basic cleaning and check-ups every month, depending on the harshness of your environment. This chapter provides you with a cleaning procedure and some troubleshooting techniques.

CLEANING PROCEDURE The Model 20 enclosure is tightly sealed to prevent dust or dirt from entering the unit. Nothing inside of the Model 20 needs to be cleaned on a regular basis. If the Model 20 needs repair, do not open the unit. The Model 20 is designed to be shipped back for repair. Refer to the Customer Service Section of this manual. To clean the Model 20: 1. Slightly dampen a lint-free cloth with a solution made of mild detergent and water. 2. Gently wipe the enclosure of the Model 20. Be careful to avoid the exit window. 3. Dry the enclosure of the Model 20 with a dry lint-free cloth. To clean the Model 20 exit window: 1. Dampen a lint-free tissue with distilled water and wipe off any dust particles. 2. Dry the exit window with a dry lint-free tissue.

Solutions with Vision

Page 54

4-4

MODEL 20 OPERATIONS AND MAINTENANCE MANUAL

TROUBLESHOOTING YOUR MODEL 20 Use the following chart to help troubleshoot the Model 20. If your Model 20 is damaged, please contact our Customer Service Department at 1-800-BARCODE. Please refer to the Customer Service Section in the front of this manual for more information about your equipment.

Accu-Sort Systems

Page 55

MAINTAINING AND TROUBLESHOOTING YOUR MODEL 20

4-5

PROBLEM/SOLUTION TABLE The following is a list of events that can occur with your scanning system. Below each event has a cause and solution. Problem The Status LED turns red for and extended period of time or it blinks There is no laser beam exiting from the scanner when power is supplied The Model 20 is not reading bar codes Model 20 has poor read rate Model 20 has poor read rate in hardware trigger Model 20 has poor read rate in serial trigger

No communication to host

Cause

Solution

The Model 20 detects a failure.

Call Accu-Sort Customer Service

No power is applied to the Model 20.

Check to ensure power is plugged in and power is applied to the interface connector. Enable code type or correct code length Clean Model 20 window, check reading range or label, or check code quality. Adjust the photoeye

Code type is not enabled or wrong code length Model 20 window is dirty, label is not within reading range, or label quality is poor. Photoeye not adjusted, or it is misaligned. Serial trigger is not timed properly with the arrival of the bar code. Host communication to scanner does not match

Adjust the timing of your serial trigger so it turns on before the bar code and turns off after the bar code. Connect the Model 20 to a PC and use your Accu-Setup Suite Small Scanner Module Programming Manual to confirm communications parameters.

Solutions with Vision

Page 56

4-6

Accu-Sort Systems

MODEL 20 OPERATIONS AND MAINTENANCE MANUAL

Page 57

Appendix A ASCII Communications

AHeading 2

Appendix A

Contents

ASCII COMMUNICATIONS..........................................................................A-3 STANDARD RS485 MULTIDROP COMMUNICATIONS ................................A-3 MESSAGE FORMATS ..............................................................................A-4 MESSAGE SEQUENCING ........................................................................A-5 TIMING ..................................................................................................A-5 MULTIDROP PROTOCOL EXAMPLES........................................................A-7 PROTOCOLS USED WITH RS232, CURRENT LOOP, AND 422 ..................A-8 ASCII CHART ...........................................................................................A-9

Page 58

A-2

Accu-Sort Systems

MODEL 20 OPERATIONS AND MAINTENANCE MANUAL

Page 59

APPENDIX A - ASCII COMMUNICATIONS

A-3

ASCII COMMUNICATIONS STANDARD RS485 MULTIDROP COMMUNICATIONS RS485 communications is an Engineering Industries Association standard for the transmitters and receivers of a digital equipment interface. RS485 communication uses differential signal lines and allows for multiple transmitters on one signal pair (although only one transmitter may be enabled at any given time). This is a way of allowing one device to communicate with one or more other devices using the Master/Slave method. The Master/Slave system works as follows: The master device (usually a decoder logic or computer) originates poll messages. The poll message is a message from the master to a slave requesting the slave to respond with data (if data is available). The slave is usually a bar code scanner. The slave device responds to the polls from the master. It is not allowed to transmit unless it has been “asked” (polled) by the master. Shown below is a simplified drawing of one way that RS485 communications works: This representation shows one Master and six slaves. You can ultimately have up to 32 slaves for each serial port on the master (depending on the line length and required response time).

RS485 Communications Example

The remainder of this section defines the message formats and timing requirements for the protocol used on RS485 multidrop (2-wire) communications lines. The protocol is defined for both the “master” device and the “slave” devices. This protocol is defined for a one-master system only. The following definitions may help you understand this protocol a little better. ASCII digit HEX digit

This means the ASCII code for a single decimal digit. For example, 30h is the ASCII digit that encodes a zero. This means the ASCII code for a single hexadecimal digit. Some examples are, 35h is the code for a five, 42h is the code for a "B" (which equals 11 base 10), the hexadecimal number "5A" would be encoded by the two HEX digits 35h and 41h.

Solutions with Vision

Page 60

A-4

MODEL 20 OPERATIONS AND MAINTENANCE MANUAL

MESSAGE FORMATS The standard communications parameters are as follows: Standard asynchronous data frame (least significant bit first) 7 data bits 1 even parity bit 2 stop bits

If the master can only support 8 bit data plus a parity bit, the format is as follows: 8 data bits 1 odd parity bit 1 stop bit

(Odd parity is required to make sure that the guard character will be all ones with one for parity.) You can use any baud rate that is supported by both the master and the slaves. System performance is usually best when using the highest baud rate possible. The following is framing for all messages sent by any device on the multidrop line: 0FFH (FFhex) = Guard Character STX(02hex) = Start of text character ID(2 ASCII digits) = The unit ID

TYPE(2 ASCII digits) = The message type Message Types 01 02

STX ID(2) TYPE(2)

SEQ DATA LRC(2)

CR

This character is "sacrificed" to the line noise that occurs when the unit transmitter is first turned on. The unit software may (optionally) wait one character time between transmitter enable and transmission of the STX (the next character). This eliminates transmitting the guard character. The receiver ignores this character. This character indicates the start of a message. The receiver should clear any characters in its receive buffer whenever it receives this character. This field indicates the unit identification number of the unit to which the message is directed, if the message is coming from the master. This field indicates the unit identification number of the unit transmitting the message, if the message is from a slave. A message with an ID of "00" from the master is a broadcast message. All slave units should act on the message (display data, reset, etc.), but no slave should respond to the message. This field describes the purpose of the message that is sent. There are five message types as shown below:

Poll Data

This message type is sent by the master unit to request data from a slave. This message type is sent by either a master to transfer data to a slave or by a slave to transfer data to the master after receiving a poll. The TYPE field will then be followed by a SEQ field and a data field. 03 ACK This message type is sent by the unit that has just received a valid data message. 04 Wake up This message type is sent by the master. The slave that receives it should acknowledge the message. 05 No data This message type may be sent by a slave indicating that the slave has no data to send in response to a poll. This message is optional. If the slave has no data, it may ignore the poll. This field starts at zero at power up, and is incremented by one for each data message sent. When SEQ(1 ASCII digit) = The sequence number the sequence number reaches nine, it wraps around to one. This field is only present in a data message. This field contains data, if the message type indicates that data is included. This field may contain DATA = no characters (length of zero; poll, acknowledge and wake up messages do not have data fields.) The content of the data field LRC(2 HEX digits) = The Linear Redundancy Check Sequence CR (0Dh) = Carriage return

Accu-Sort Systems

The LRC is computed by exclusive-oring all the characters in the ID, TYPE, SEQ, and data fields, then converting the hex number into two ascii digits. This mathematical process checks to make sure that the message is valid. This character indicates the end of the message. When this character is received, the unit should check to see that the message started with a STX, and check that the LRC is correct before accepting it as a valid message.